Transform your home with the latest multi-electronics solutions, from intelligent lighting to vOptimize your operations with the Bently Nevada 3500 Monitoring System, offering real-time vibration and machinery condition monitoring to prevent failures and maximize uptime.oice-controlled devices all designed to make life easier, safer, and more connected.
SKU:T8461
ICS Triplex T8461 Digital Output TMR Module 40 Channel
Manufacturer: ICS Triplex
Product No.: T8461
Product Type: Digital Output Module
Product Origin: USA
Payment:T/T, Western Union
Weight: 1285g
Shipping port: Xiamen
Warranty: 12 months
Share
- Fast Delivery
- 24/7 Support
- Quality Assurance
Description
Product Overview
The ICS Triplex T8461 is a TMR digital output module with 40 channels, designed for high‑integrity actuation in safety‑critical systems. It delivers 0.75 A per channel across 5 isolated power groups (8 outputs each). The fully triplicated architecture ensures fail‑safe operation, making it ideal for emergency shutdown (ESD), fire & gas, and burner management applications requiring SIL 3 compliance.
Core Advantages
Triple Modular Redundancy
Fully triplicated with 2‑out‑of‑3 voting. Any single fault is automatically masked, guaranteeing continuous, safe output actuation without spurious trips.
Flexible Field Voltage Range
Accepts field voltages from 18 to 60 Vdc, accommodating diverse actuator and solenoid requirements. The 5 independent power groups allow segregated loads for enhanced diagnostics.
High Capacitive Load Capability
Release 3.5 supports up to 3500 µF at 0.75 A, making it suitable for driving large solenoids and valves with high inrush currents.
Specifications
| Parameter | Value |
|---|---|
| System Supply Voltage | 20–32 Vdc |
| System Supply Power | 22 W |
| Field Supply Power (at 24V, 0.75A/ch) | 18 W |
| Output Channels | 40 (5 groups × 8) |
| Operational Field Voltage | 18–60 Vdc |
| Output Current (continuous) | 0.75 A/ch, 6 A/group |
| Min. On‑State Load Current | 25 mA |
| Output On‑State Resistance | 0.6 Ω |
| Off‑State Leakage (equiv. resistance) | 33 kΩ |
| Max Capacitive Load (Release 3.5) | 3500 µF at 0.75 A |
| Turn‑on/off Delay | 0.5 ms |
| Self‑Test Interval | 2 minutes |
| Event Resolution / Accuracy | 1 ms / ±0.5 ms |
| Operating Temperature | -5 °C to +60 °C |
| Humidity | 5–95% RH non‑condensing |
| Certifications | ATEX, IECEx, HazLoc, Ordinary Location |
| Dimensions (H×W×D) | 266 × 31 × 303 mm |
| Weight | 1.285 kg |
Installation Tips
Power Group Segregation
Distribute loads across the 5 independent power groups (8 outputs each) to isolate faults and simplify troubleshooting. Each group has its own field supply return.
Output Wiring
Use shielded cables for field wiring, especially in high‑EMI environments. Keep cable lengths under 30 m to minimise voltage drop and crosstalk.
Capacitive Loads
For loads >55 µF, ensure the module is Release 3.5 or later. It supports up to 3500 µF at 0.75 A, ideal for large solenoids with high inrush.
Hazardous Area
For intrinsic safety, use external barriers as specified. Follow ATEX/IECEx installation rules: certified glands, proper segregation, and observe temperature class.
Why Choose T8461?
Delivers 40 high‑current outputs in a compact 31 mm wide package. The TMR architecture eliminates single points of failure, while the 0.5 ms turn‑on/off delay ensures fast response for critical trips. Withstands harsh industrial environments and integrates seamlessly with ICS Triplex Trusted systems. The high capacitive load capability (3500 µF) reduces the need for external interposing relays, saving panel space and cost.
FAQs
Q1: What is the difference between Release 3.5 and earlier versions?
A1: Release 3.5 increases capacitive load support from 55 µF to 3500 µF at 0.75 A. Recommended for large solenoids or long cable runs.
Q2: Can I use the T8461 with a 48 Vdc field supply?
A2: Yes. The operational field voltage range is 18–60 Vdc, fully compatible with 48 Vdc systems. Ensure total group current stays under 6 A.
Q3: What does the 33 kΩ off‑state leakage mean?
A3: This is the effective leakage resistance when output is off. At 48 Vdc, leakage is below 1.5 mA, preventing false actuation of sensitive loads.
Additional Specifications
Scalar (V/f)
Vector
AC-powered
Buying Guide
- Confirm the exact model, part number, and specifications before ordering.
- Ensure compatibility with your current machinery or control systems.
- Reach out via sale@etowonauto.com or +8617859788089 for technical assistance.
- Review delivery options, lead times, and shipping requirements.
- Follow manufacturer instructions and best practices during installation.
Shipping And Return
In-stock items are typically dispatched the same business day. For products not currently in stock, dispatch times may vary based on availability. International shipping is available, and shipping costs are calculated according to destination, weight, and carrier selection.
Returns are accepted within 30 days of receipt, provided items are unused and in original condition. Return shipping costs are the responsibility of the customer. Please contact us before returning any item to receive return authorization.
For more details, please review our Shipping & Return Policy.

3500/61-05-CN Temperature Monitor Module | Bently Nevada
3500/22-01-02-CN TDI Module Bently Nevada
Bently Nevada 3500/42-04-00 | Seismic Monitor
-
Fast Shipping
Original industrial automation parts available for prompt shipment worldwide.
-
Easy Returns
30-day return support with a 12-month warranty for reliable after-sales protection.
-
24/7 support
Responsive professional support to help maintain stable and efficient operations.
-
Genuine & Original
100% authentic, sourced directly from trusted industrial automation manufacturers.
Technical & Buying Guide
-
How does ABB S800 I/O hot swap cut unplanned downtime by 90%?
This article presents quantified operational best practices for ABB S800 I/O hot swap in 24/7 process industries. ...
-
Is Your Refinery DCS Ready for Zero-Trust OT Access Control?
This technical article examines data-driven cybersecurity hardening strategies for Emerson DeltaV DCS in refiner...
-
How to Quantify and Fix Allen‑Bradley HMI Flickering in Cement Plants?
This technical article presents quantified field data from 2021–2026 on Allen‑Bradley HMI flickering in cement plants...
-
How to Fix HMI Flickering Caused by Power Noise and Vibration?
This article presents quantified field data from 2021–2026 on Allen‑Bradley HMI flickering faults in cement productio...
-
Stop 68% of DCS Faults with Proven Transmitter Matching Rules?
This article presents field-verified solutions for optimizing communication between Rosemount transmitters and Emerso...
-
What Does Poor PLC Backup Cost Your Paper Plant?
This technical article presents quantified backup and recovery standards for GE Fanuc RX7i PLCs in high-capacity pape...