Transform your home with the latest multi-electronics solutions, from intelligent lighting to vOptimize your operations with the Bently Nevada 3500 Monitoring System, offering real-time vibration and machinery condition monitoring to prevent failures and maximize uptime.oice-controlled devices all designed to make life easier, safer, and more connected.
SKU:IC697ALG444
IC697ALG444 GE Fanuc 16-Bit Voltage Current Input Board
Manufacturer: General Electric
Product No.: IC697ALG444
Product Type: Analog Input Module
Product Origin: USA
Payment:T/T, Western Union
Weight: 350g
Shipping port: Xiamen
Warranty: 12 months
Share
- Fast Delivery
- 24/7 Support
- Quality Assurance
Description
Product Overview
The IC697ALG444 is a high-density, 16-channel Analog Input Module manufactured by GE Fanuc (now Emerson Automation) for the legacy Series 90-70 programmable logic controller system. This high-performance hardware block processes accurate analog field variables across 16 independent channels, accommodating both voltage (−10V to +10V DC) and current (4 mA to 20 mA) loops. Utilizing an advanced 16-bit analog-to-digital converter core, this module features a compact and lightweight footprint weighing approximately 0.35 kg (0.77 lbs), allowing it to translate real-world physical dynamics into precise control registers without adding significant mechanical stress to the rack.
Core Technical Advantages
- 16-Bit High-Resolution Data Conversion: Delivers sharp granularity representing 0.0015% of the Full Scale (FS) envelope. This allows control algorithms to register minute shifts in pressure, thermal metrics, or fluid rates.
- Superior Electrical Channel Isolation: Built with an intensive 1500V AC dielectric barrier protecting internal backplane logic from external channel-to-chassis faults, keeping logic loops fully shielded.
- Rapid Update Response Cycle: Features an optimized 1 millisecond conversion multiplex rate per channel, facilitating stable execution across fast-acting multi-loop processing arrays.
Technical Specifications
| Parameter | Specification Details |
|---|---|
| Product Model Designation | IC697ALG444 |
| System Architecture | GE Fanuc Series 90-70 PLC Framework |
| Total Active Channels | 16 independent inputs (Single-ended arrangement) |
| Voltage Measurement Span | −10 Volts to +10 Volts DC |
| Current Measurement Scope | 4 mA to 20 mA instrument loops |
| Hardware Base Resolution | 16-bit analog-to-digital processing |
| Total Absolute Accuracy | ±0.03% of active reading data |
| Internal Channel Impedance | 250 Ω nominal current loop loop-drop resistance |
| Power Consumed Load | 200 mW maximum per active input loop channel |
| Product Net Weight | 0.35 kg (0.77 lbs) |
Industrial Applications
- Oil and Gas Refining Facilities: Tracks accurate chemical pressure loops and gas storage cell volume metrics over widespread petrochemical production plants.
- Metal Processing Foundries: Interfaces with thermal transmitter devices to govern extreme heat treatment variables across steel ladle tracking platforms.
- Water Treatment Filtration Control: Regulates proportional input metering and volumetric tracking flowmeters inside distribution treatment facilities.
- Paper Packaging Facilities: Measures high-accuracy tensile mechanical stress sensors to balance paper line speeds and minimize product tearing hazards.
Wiring & Installation
- Terminal Block Coordination: Use an IC697ACC775 terminal block for field wire termination. This ensures proper alignment with the module's front pin receivers.
- Current Loop Shunt Jumper Setup: When mapping the channels for standard 4-20 mA current inputs, ensure internal shunt paths or external pin jump settings match the input parameters to maintain the 250 Ω impedance loop configuration.
- Shield Termination Best Practices: Terminate analog signal cable shield lines at a single grounding rail point, preferably near the chassis wall, to prevent noise from inducing signal drift.
- Cold-Cabinet Module Placement: Always switch off the master chassis power grid before inserting or removing the module. This protects backplane logic from data bus spikes.
Engineering Advantages
- Factory-Calibrated Precision: Every unit leaves the production line tuned to a tight standard baseline of 10V ± 2 mV. This reduces down-time by eliminating the need for periodic field adjustment.
- Excellent Thermal Envelope: Operates efficiently across an extended industrial temperature spectrum spanning from −20°C up to +60°C without triggering thermal derating penalties.
- Flexible Network Routing Integration: Processes field inputs smoothly across varied master communication networks, including Ethernet links, legacy Genius LAN structures, and point-to-point serial configurations.
Technical FAQs
Q1: Can I mix voltage signals and current loops simultaneously on a single IC697ALG444 board?
A1: Yes. Channels can be individually configured and wired for either voltage or current inputs, provided you assign the correct field wiring connections and register scaling settings in your software environment.
Q2: What is the benefit of the IC697ACC775 terminal connector kit?
A2: The IC697ACC775 provides a structured terminal matrix that supports heavy field wire gauge sizing while preventing raw line fatigue from transferring onto the internal processing card components.
Q3: Does the 1500V AC isolation cover channel-to-channel paths or just loop-to-backplane tracks?
A3: The high-voltage dielectric isolation is rated between the input circuit channels as a group and the sensitive logic backplane track, safeguarding the central CPU from unexpected external field transients.
Additional Specifications
Scalar (V/f)
Vector
AC-powered
Buying Guide
- Confirm the exact model, part number, and specifications before ordering.
- Ensure compatibility with your current machinery or control systems.
- Reach out via sale@etowonauto.com or +8617859788089 for technical assistance.
- Review delivery options, lead times, and shipping requirements.
- Follow manufacturer instructions and best practices during installation.
Shipping And Return
In-stock items are typically dispatched the same business day. For products not currently in stock, dispatch times may vary based on availability. International shipping is available, and shipping costs are calculated according to destination, weight, and carrier selection.
Returns are accepted within 30 days of receipt, provided items are unused and in original condition. Return shipping costs are the responsibility of the customer. Please contact us before returning any item to receive return authorization.
For more details, please review our Shipping & Return Policy.

3500/61-05-CN Temperature Monitor Module | Bently Nevada
3500/22-01-02-CN TDI Module Bently Nevada
Bently Nevada 3500/42-04-00 | Seismic Monitor
-
Fast Shipping
Original industrial automation parts available for prompt shipment worldwide.
-
Easy Returns
30-day return support with a 12-month warranty for reliable after-sales protection.
-
24/7 support
Responsive professional support to help maintain stable and efficient operations.
-
Genuine & Original
100% authentic, sourced directly from trusted industrial automation manufacturers.
Technical & Buying Guide
-
How does hierarchical control raise factory OEE from 64% to 82%?
This article explains how hierarchical cloud-edge collaborative control replaces fragmented industrial architectures....
-
Can DCS Intelligent Regulation Fix Thermal Power Energy Imbalance?
This article explains how intelligent DCS regulation with MPC and cloud-based control solves energy-production imbala...
-
Can Continuous Automation Iteration Cut Factory Costs by 18-25%?
Static industrial control systems create hidden annual cost increases of 18-25%. Phased PLC and DCS program iteration...
-
Can Anti-Interference Hardware End 38% of Automation Downtime?
Field data from chemical, wind, and automotive plants proves that industrial hardware with full IEC 61000-4 EMC certi...
-
How Does Full-Lifecycle Management Optimize PLC and DCS Assets?
Traditional industrial asset management relies on manual logging and reactive troubleshooting, causing 15–20% annual ...
-
Can an Integrated Spare Chain Slash Downtime?
Unplanned equipment failures cost Chinese factories ¥636,000 per hour. Traditional cross-border spare procurement tak...