Transform your home with the latest multi-electronics solutions, from intelligent lighting to vOptimize your operations with the Bently Nevada 3500 Monitoring System, offering real-time vibration and machinery condition monitoring to prevent failures and maximize uptime.oice-controlled devices all designed to make life easier, safer, and more connected.
SKU:IC697ALG440
IC697ALG440 GE Fanuc Series 90-30 Analog Input Card
Manufacturer: General Electric
Product No.: IC697ALG440
Product Type: Current Expander Module
Product Origin: USA
Payment:T/T, Western Union
Weight: 610g
Shipping port: Xiamen
Warranty: 12 months
Share
- Fast Delivery
- 24/7 Support
- Quality Assurance
Description
Product Overview
The GE Fanuc IC697ALG440 is a high-density, 16-channel Analog Input Expander Module engineered to scale up the monitoring capacity of your GE Series 90 industrial control system. Weighing just 0.61 kilograms (1.34 lbs) with a compact 4 cm x 21.8 cm x 29.2 cm profile, this module serves as an expansion interface that captures a high volume of field data. By pairing seamlessly with base converter modules, it enables complex control systems to monitor extensive arrays of 4-20 mA and voltage transmitters simultaneously.
Core Technical Advantages
- 16-Channel High-Density Expansion: Maximizes rack real estate by packing 16 distinct current inputs onto a single slot footprint, lowering overall hardware installation costs.
- Dual-Signal Compatibility Range: Built to process both standard 4 to 20 mA industrial current loops and versatile -10 to +10 VDC voltage spans for wide-ranging process telemetry.
- Factory-Calibrated Precision: Shipped with a highly stable factory calibration set at 10 Volts ±2mV, providing exceptional plug-and-play measurement accuracy directly out of the box.
Technical Specifications
| Parameter | Specification Details |
|---|---|
| Brand / Model Part No. | GE Fanuc / IC697ALG440 |
| Gross Weight | 0.61 kilograms (1.34 lbs) |
| Module Classification | Analog Input Expander Module (Series 90 Platform) |
| Total Signal Inputs | 16 Current / Voltage Input Channels |
| Current Signal Window | 4 to 20 mA loop current range |
| Voltage Signal Window | -10 VDC to +10 VDC range |
| Calibration Reference Limit | Factory set at 10 Volts ±2 mV |
| Internal Power Consumption | +5 VDC backplane logic power supply requirement |
| Physical Form Dimensions | 4.0 cm (W) x 21.8 cm (D) x 29.2 cm (H) |
Installation & Engineering Guide
- Hardware Pairing Setup: Slide the lightweight 0.61 kg expander card into its designated slot immediately adjacent to the base analog converter module. Ensure backplane connectors mate cleanly to maintain reliable bus expansion.
- Field Instrument Shielding: Wire your 4-20mA or ±10V instrumentation directly to the module terminal blocks. Run all signal cabling through separate grounded industrial conduits to shield the high-density analog matrix from high-power electromagnetic emissions.
- Thermal Management: Maintain proper air gaps around the 4 cm wide housing. Its energy-efficient design requires low power, but clean convection routing inside the enclosure helps prevent heat pooling from surrounding equipment.
Technical FAQs
Q1: Does the IC697ALG440 act as a standalone analog processing module?
A1: No. This hardware is classified as an expander module; it must be coupled with a primary base analog converter module to pass digitized instrumentation loop signals to the processor.
Q2: What benefit does the factory-set 10V ±2mV calibration offer during installation?
A2: It guarantees highly stable operational baselines without demanding field calibration adjustments during hardware commission, saving considerable engineering hours on startup.
Q3: Can this compact module be mounted into tight enclosure assemblies safely?
A3: Yes. With physical dimensions of 4 cm x 21.8 cm x 29.2 cm, its compact footprint fits cleanly into standard depth industrial cabinets while providing robust 16-channel tracking.
Additional Specifications
Scalar (V/f)
Vector
AC-powered
Buying Guide
- Confirm the exact model, part number, and specifications before ordering.
- Ensure compatibility with your current machinery or control systems.
- Reach out via sale@etowonauto.com or +8617859788089 for technical assistance.
- Review delivery options, lead times, and shipping requirements.
- Follow manufacturer instructions and best practices during installation.
Shipping And Return
In-stock items are typically dispatched the same business day. For products not currently in stock, dispatch times may vary based on availability. International shipping is available, and shipping costs are calculated according to destination, weight, and carrier selection.
Returns are accepted within 30 days of receipt, provided items are unused and in original condition. Return shipping costs are the responsibility of the customer. Please contact us before returning any item to receive return authorization.
For more details, please review our Shipping & Return Policy.

3500/61-05-CN Temperature Monitor Module | Bently Nevada
3500/22-01-02-CN TDI Module Bently Nevada
Bently Nevada 3500/42-04-00 | Seismic Monitor
-
Fast Shipping
Original industrial automation parts available for prompt shipment worldwide.
-
Easy Returns
30-day return support with a 12-month warranty for reliable after-sales protection.
-
24/7 support
Responsive professional support to help maintain stable and efficient operations.
-
Genuine & Original
100% authentic, sourced directly from trusted industrial automation manufacturers.
Technical & Buying Guide
-
Can Collaborative DCS Cut Load Response Delays Below 0.4 Seconds?
This paper presents a hierarchical DCS architecture for multi-unit collaborative control in thermal power stations. F...
-
How to Stop PLC Failure from Cabinet Heat?
This article reveals how hidden heat inside control cabinets causes 68% of random automation faults, compares MTBF be...
-
Can PLC Rewriting Replace Full Hardware Retrofit?
This article explains how cross-brand PLC code migration replaces full hardware replacement for legacy production lin...
-
Can Emerson Fix ISO 50001 Data Gaps in Old Factories?
This article explains why conventional PLC and DCS systems lack granular energy monitoring for ISO 50001 compliance. ...
-
Why does PLC signal interference cause 61% of shutdowns?
Heavy-duty lines have 3.2x more control faults than assembly lines due to EMI and load shocks. Standard PLCs cannot a...
-
What Is the Verified ROI of Cloud Automation?
Global manufacturers face scattered sites and limited maintenance staff. This article presents verified field data fr...