Transform your home with the latest multi-electronics solutions, from intelligent lighting to vOptimize your operations with the Bently Nevada 3500 Monitoring System, offering real-time vibration and machinery condition monitoring to prevent failures and maximize uptime.oice-controlled devices all designed to make life easier, safer, and more connected.
SKU:IC693MDL940
IC693MDL940 24VDC/240VAC Output Module GE
Manufacturer: General Electric
Product No.: IC693MDL940
Product Type: Output Module
Product Origin: USA
Payment:T/T, Western Union
Weight: 400g
Shipping port: Xiamen
Warranty: 12 months
Share
- Fast Delivery
- 24/7 Support
- Quality Assurance
Description
Product Overview
The GE Fanuc IC693MDL940 is a high-performance relay output module designed for the Series 90-30 Programmable Logic Controller. It provides 16 discrete outputs, arranged in four isolated groups of four, allowing for the switching of different voltage sources within a single module. With a net weight of 0.4 kg (0.88 lbs), this unit offers a compact yet powerful interface for high-current industrial loads. It is engineered to handle both AC and DC voltages, making it a versatile choice for applications requiring mechanical contact isolation and high current-carrying capacity.
Core Technical Advantages
The IC693MDL940 is built for heavy-duty operation, supporting a maximum load of 2 Amps per output and a total module capacity of 16 Amps. This 0.4 kg module features a rapid response time of 15 ms for both "on" and "off" cycles, ensuring timely execution of control logic. To protect sensitive backplane electronics, the module provides 1500 VAC isolation for one minute between the field side and the logic side. Additionally, with its low power draw of only 7 mA from the 5V bus, it minimizes the thermal load on the PLC power supply even when all 16 relays are energized.
Technical Specifications
| Feature | Details |
|---|---|
| Brand | GE Fanuc (Emerson) |
| Model Number | IC693MDL940 |
| Outputs | 16 Points (4 Groups of 4) |
| Load Rating | 2 Amps per point (Max) |
| Unit Weight | 0.4 kg (0.88 lbs) |
| Operating Voltage | 5-250 VAC / 5-30 VDC |
Installation & Wiring Guidelines
When installing the GE Fanuc IC693MDL940, ensure the PLC rack power is disconnected before insertion. The 0.4 kg unit fits into any I/O slot of the Series 90-30 baseplate. Because the module can switch up to 250 VAC, users must adhere to local wiring codes, particularly regarding point-to-point isolation. The module supports a maximum common load of 4 Amps per group. It is recommended to use surge suppression (such as MOV or RC snubbers) when driving inductive loads to extend the mechanical life of the relay contacts and prevent EMI interference with adjacent modules.
Engineering Advantages
Engineers prefer the IC693MDL940 for its high-density relay count, which significantly reduces the number of modules required for large-scale output control. The mechanical relay design eliminates the leakage current issues found in Triac or Transistor modules, providing a "true open" state that is safer for certain maintenance procedures. Despite its 0.4 kg physical profile, the module is exceptionally rugged, capable of handling inrush currents up to 5 Amps. Its ability to switch mixed loads (AC and DC) within different groups makes it an incredibly flexible tool for modernizing legacy control systems.
Technical FAQs
Q1: What is the weight of the GE Fanuc IC693MDL940?
A1: This module has a net weight of 0.4 kg (0.88 lbs), reflecting its robust internal relay array and protective housing.
Q2: What is the minimum load requirement for the relays?
A2: To ensure reliable contact closing and prevent oxidation buildup, a minimum load of 10 mA is required for each output point.
Q3: Does the IC693MDL940 require an external power source?
A3: Yes, while the logic side is powered by the backplane, the relay coils require 135 mA from the 24V bus (typically provided by the PLC power supply) when all outputs are energized.
Additional Specifications
Scalar (V/f)
Vector
AC-powered
Buying Guide
- Confirm the exact model, part number, and specifications before ordering.
- Ensure compatibility with your current machinery or control systems.
- Reach out via sale@etowonauto.com or +8617859788089 for technical assistance.
- Review delivery options, lead times, and shipping requirements.
- Follow manufacturer instructions and best practices during installation.
Shipping And Return
In-stock items are typically dispatched the same business day. For products not currently in stock, dispatch times may vary based on availability. International shipping is available, and shipping costs are calculated according to destination, weight, and carrier selection.
Returns are accepted within 30 days of receipt, provided items are unused and in original condition. Return shipping costs are the responsibility of the customer. Please contact us before returning any item to receive return authorization.
For more details, please review our Shipping & Return Policy.

3500/61-05-CN Temperature Monitor Module | Bently Nevada
3500/22-01-02-CN TDI Module Bently Nevada
Bently Nevada 3500/42-04-00 | Seismic Monitor
-
Fast Shipping
Original industrial automation parts available for prompt shipment worldwide.
-
Easy Returns
30-day return support with a 12-month warranty for reliable after-sales protection.
-
24/7 support
Responsive professional support to help maintain stable and efficient operations.
-
Genuine & Original
100% authentic, sourced directly from trusted industrial automation manufacturers.
Technical & Buying Guide
-
Why Is 99.8% Reliability Critical for Your PLC and DCS Systems?
This article explains why rigorously vetted cross-border control parts stabilize industrial automation operations. It...
-
Can Joint Control Optimization Boost Manufacturing OEE by 20%?
Traditional disconnected PLC and DCS systems cause 10–18% daily idle time between production stages. This article pre...
-
How does hierarchical control raise factory OEE from 64% to 82%?
This article explains how hierarchical cloud-edge collaborative control replaces fragmented industrial architectures....
-
Can DCS Intelligent Regulation Fix Thermal Power Energy Imbalance?
This article explains how intelligent DCS regulation with MPC and cloud-based control solves energy-production imbala...
-
Can Continuous Automation Iteration Cut Factory Costs by 18-25%?
Static industrial control systems create hidden annual cost increases of 18-25%. Phased PLC and DCS program iteration...
-
Can Anti-Interference Hardware End 38% of Automation Downtime?
Field data from chemical, wind, and automotive plants proves that industrial hardware with full IEC 61000-4 EMC certi...