Transform your home with the latest multi-electronics solutions, from intelligent lighting to vOptimize your operations with the Bently Nevada 3500 Monitoring System, offering real-time vibration and machinery condition monitoring to prevent failures and maximize uptime.oice-controlled devices all designed to make life easier, safer, and more connected.
SKU:IC670ALG630
IC670ALG630 8-Input Thermocouple Module GE Fanuc
Manufacturer: General Electric
Product No.: IC670ALG630
Product Type: Thermocouple Input Module
Product Origin: USA
Payment:T/T, Western Union
Weight: 500g
Shipping port: Xiamen
Warranty: 12 months
Share
- Fast Delivery
- 24/7 Support
- Quality Assurance
Description
GE Fanuc IC670ALG630 8-Channel Thermocouple Input Module
This professional introduction presents the IC670ALG630 module from GE Fanuc. This reliable module delivers precise temperature measurement for industrial control systems. It connects directly to the Genius bus through a Field Control Bus Interface Unit.
Core Product Specifications
- Brand & Model: GE Fanuc IC670ALG630
- Input Channels: 8 fully isolated thermocouple inputs.
- Measurement Range: The module offers six selectable voltage spans from ±19.5 mV to ±625 mV.
- Thermocouple Compatibility: It supports types J, K, T, E, S, R, B, N, G, C, D, and Platinel II.
- Resolution: The analog-to-digital converter provides a high 15-bit plus sign resolution.
- Sensitivity & Linearity: Temperature sensitivity is within ±0.004% of the reading over its operating range.
- Environmental Tolerance: It operates reliably in temperatures from 0°C to 55°C (32°F to 131°F).
- Noise Immunity: Channels have strong isolation, withstanding up to 250 VAC between them.
- Current Consumption: The module draws a maximum of 195 mA from the Bus Interface Unit.
- Enclosure Rating: It has an IP20 rating for basic protection against dust and contact.
Frequently Asked Questions (FAQ)
-
Q: How many thermocouple types can this GE Fanuc module read?
A: The module is versatile and supports twelve common types, including J, K, T, E, S, R, B, N, G, C, D, and Platinel II. -
Q: What is the maximum voltage isolation between input channels?
A: The channels on the IC670ALG630 are isolated to handle up to 250 VAC between them for safety and noise rejection. -
Q: How do I configure the module after installation?
A: You must configure it through the Genius Bus Interface Unit using a compatible handheld programmer or configuration software.
Additional Specifications
- Black
Scalar (V/f)
Vector
AC-powered
Buying Guide
- Confirm the exact model, part number, and specifications before ordering.
- Ensure compatibility with your current machinery or control systems.
- Reach out via sale@etowonauto.com or +8617859788089 for technical assistance.
- Review delivery options, lead times, and shipping requirements.
- Follow manufacturer instructions and best practices during installation.
Shipping And Return
In-stock items are typically dispatched the same business day. For products not currently in stock, dispatch times may vary based on availability. International shipping is available, and shipping costs are calculated according to destination, weight, and carrier selection.
Returns are accepted within 30 days of receipt, provided items are unused and in original condition. Return shipping costs are the responsibility of the customer. Please contact us before returning any item to receive return authorization.
For more details, please review our Shipping & Return Policy.

3500/61-05-CN Temperature Monitor Module | Bently Nevada
3500/22-01-02-CN TDI Module Bently Nevada
Bently Nevada 3500/42-04-00 | Seismic Monitor
-
Fast Shipping
Original industrial automation parts available for prompt shipment worldwide.
-
Easy Returns
30-day return support with a 12-month warranty for reliable after-sales protection.
-
24/7 support
Responsive professional support to help maintain stable and efficient operations.
-
Genuine & Original
100% authentic, sourced directly from trusted industrial automation manufacturers.
Technical & Buying Guide
-
What Is the Real Hourly Cost of Automation Downtime?
Industrial automation downtime creates severe financial losses, with PLC and DCS hardware failures causing 62% of unp...
-
Does Bently Nevada & PLC Integration Cut Refinery Downtime?
This article details a field-validated Bently Nevada 3500 and Allen-Bradley ControlLogix integration for oil and gas ...
-
Is Your Plant Ready for ABB-GE Fanuc Hybrid Control?
This article examines a hybrid ABB DCS and GE Fanuc PLC architecture for aging metallurgical lines, delivering 99.8% ...
-
Can Bently Nevada Integrate with Emerson DCS?
This article explores how Bently Nevada 3500 TSI and Emerson DeltaV DCS integration delivers measurable predictive ma...
-
Why 38% of Refinery Shutdowns Start with Aging PLCs?
This article examines how genuine GE Fanuc PLC spare parts and Bently Nevada TSI monitoring cards enable Industry 4.0...
-
Can Integrated DCS-PLC Solve Food Production Inconsistency?
This article examines how integrating Emerson DeltaV DCS with Allen‑Bradley PLC resolves food manufacturing control p...
