Transform your home with the latest multi-electronics solutions, from intelligent lighting to vOptimize your operations with the Bently Nevada 3500 Monitoring System, offering real-time vibration and machinery condition monitoring to prevent failures and maximize uptime.oice-controlled devices all designed to make life easier, safer, and more connected.
SKU:FC-IOCHAS-0001R
Honeywell FC-IOCHAS-0001R Redundant IO Chassis
Manufacturer: Honeywell
Product No.: FC-IOCHAS-0001R
Product Type: Controller Chassis
Product Origin: USA
Payment:T/T, Western Union
Weight: 8500g
Shipping port: Xiamen
Warranty: 12 months
Share
- Fast Delivery
- 24/7 Support
- Quality Assurance
Description
Redundant IO Chassis for Safety Manager Systems
The Honeywell FC-IOCHAS-0001R and FS-IOCHAS-0001R provide a 19-inch chassis for up to 9 pairs of redundant IO modules.
Slot Configuration & Redundancy
- 21 total slots with 4TE width each, numbered 1 to 21 from left to right
- Slots 1 to 18 available for IO modules, configured as 9 redundant pairs
- Odd slots connect to Control Processor 1, even slots connect to Control Processor 2
- Slot 19 remains unused for spacing requirements
- Slot 20 and 21 contain IO-0001 modules for system interface
Component Overview
- IO housing with 21-slot capacity
- Two IO-0001 interface modules included
- Blind front covers for unused positions
- Standard 19-inch rack mount design
Technical Specifications
- Brand: Honeywell
- Models: FC-IOCHAS-0001R, FS-IOCHAS-0001R
- Approvals: CE, UL, CSA, TUV, FM
- Power consumption 5V-1: 35 mA (IO-0001 in slot 20)
- Power consumption 5V-2: 35 mA (IO-0001 in slot 21)
Physical Dimensions
- Height: 1 + 3 + 1 HE (44.5 + 133.4 + 44.5 mm / 1.75 + 5.25 + 1.75 in) for first chassis
- Height for additional chassis: 4 HE (133.4 mm / 5.25 in)
- Width: 482.6 mm (19 inches) standard rack width
- Depth: 280 mm (11 inches)
- Weight: 8.5 kg
Installation & Packaging
- Mounts in standard 19-inch equipment racks
- First chassis requires 1+3+1 HE vertical space
- Additional chassis stack using 4 HE each
- Includes chassis with pre-installed backplane
- Blind fronts for unused positions included
- Shipping: FedEx, UPS, DHL worldwide
FAQ
-
Q: How many IO module pairs can this chassis hold?
A: The IOCHAS-0001R holds up to 9 pairs of redundant IO modules in slots 1 through 18. -
Q: Why is slot 19 not usable?
A: Slot 19 provides physical spacing between IO modules and the IO-0001 interface modules in slots 20 and 21. -
Q: Can I mix different IO module types in this chassis?
A: Yes. You can use any combination of IO modules as long as you maintain the redundant pair configuration in adjacent odd/even slots.
Additional Specifications
- Gray
Scalar (V/f)
Vector
AC-powered
Buying Guide
- Confirm the exact model, part number, and specifications before ordering.
- Ensure compatibility with your current machinery or control systems.
- Reach out via sale@etowonauto.com or +8617859788089 for technical assistance.
- Review delivery options, lead times, and shipping requirements.
- Follow manufacturer instructions and best practices during installation.
Shipping And Return
In-stock items are typically dispatched the same business day. For products not currently in stock, dispatch times may vary based on availability. International shipping is available, and shipping costs are calculated according to destination, weight, and carrier selection.
Returns are accepted within 30 days of receipt, provided items are unused and in original condition. Return shipping costs are the responsibility of the customer. Please contact us before returning any item to receive return authorization.
For more details, please review our Shipping & Return Policy.

3500/61-05-CN Temperature Monitor Module | Bently Nevada
3500/22-01-02-CN TDI Module Bently Nevada
Bently Nevada 3500/42-04-00 | Seismic Monitor
-
Fast Shipping
Original industrial automation parts available for prompt shipment worldwide.
-
Easy Returns
30-day return support with a 12-month warranty for reliable after-sales protection.
-
24/7 support
Responsive professional support to help maintain stable and efficient operations.
-
Genuine & Original
100% authentic, sourced directly from trusted industrial automation manufacturers.
Technical & Buying Guide
-
Can Emerson DeltaV DCS Cards Optimize Chemical Safety Loops?
This technical article examines how Emerson DeltaV DCS card upgrades address legacy control limitations in chemical p...
-
Is Partial CNC Board Replacement Better Than a Full System Upgrade?
This technical article examines the dominance of GE Fanuc CNC hardware in heavy-duty automation, supported by field d...
-
Can Genuine PLC Modules Cut DCS Downtime 60%?
This article examines how genuine Allen-Bradley PLC module replacement strategies directly reduce unplanned DCS downt...
-
Is Your GE Fanuc PLC Talking to ABB DCS?
This article reveals how cross-system data silos between GE Fanuc PLC and ABB DCS cause 8–15% production losses in pr...
-
Can Integrated PLC-DCS-TSI Fix Data Silos?
Most industrial digital twins remain static visualization tools because discrete control, process automation, and con...
-
How to Cut Power Plant Outages with ABB and GE Fanuc Retrofits?