Transform your home with the latest multi-electronics solutions, from intelligent lighting to vOptimize your operations with the Bently Nevada 3500 Monitoring System, offering real-time vibration and machinery condition monitoring to prevent failures and maximize uptime.oice-controlled devices all designed to make life easier, safer, and more connected.
SKU:CC-TDIL11
Honeywell CC-TDIL11 24VDC Input Module
Manufacturer: Honeywell
Product No.: CC-TDIL11
Product Type: Input Module
Product Origin: USA
Payment:T/T, Western Union
Weight: 850g
Shipping port: Xiamen
Warranty: 12 months
Share
- Fast Delivery
- 24/7 Support
- Quality Assurance
Description
Honeywell CC-TDIL11: Redundant 24V Digital Input IOTA
The Honeywell CC-TDIL11 provides redundant termination for digital input signals in critical applications. This IOTA (Input/Output Termination Assembly) connects field wiring to Series C redundant systems.
Electrical Specifications
- Brand: Honeywell
- Model: CC-TDIL11
- Type: Digital Input IOTA Redundant
- Voltage: 24 VDC nominal
- Current Draw: 0.190 Amps at 24 VDC
- Heat Dissipation: 4.220 Watts
- Isolation: 1500V field to logic
Redundancy Features
- Architecture: Dual redundant input paths
- Switchover: Automatic bumpless transfer
- Monitoring: Continuous path health check
- Indicators: Per-path status LEDs
- Compatibility: Works with redundant processor pairs
Physical Characteristics
- Weight: 1.2kg (2.65 lbs)
- Dimensions: 180mm x 130mm x 60mm
- Terminals: Screw clamp type, 12-22 AWG
- Material: Steel chassis with enamel coating
- Mounting: Direct to subpanel or DIN rail adapter
- Connectors: Dual 50-pin to module cables
Environmental Ratings
- Temperature: -40°C to +70°C operating
- Storage: -55°C to +85°C
- Humidity: 5% to 95% non-condensing
- Vibration: 1mm displacement 10-55Hz
- Corrosion: Coated for harsh environments
- Protection: IP20 finger-safe terminals
Frequently Asked Questions
Q: What does the 0.190A current draw represent?
A: This is the IOTA's own power consumption from the backplane. Field devices draw separate power from your external 24V supply connected to the IOTA terminals.
Q: How does the redundancy actually work?
A: The CC-TDIL11 splits each field input to two separate input modules. If one module fails, the second continues reading the signal with zero interruption.
Q: Why 4.220 Watts heat dissipation matter?
A: This helps you calculate cabinet cooling needs. The CC-TDIL11 generates 4.22W continuously. Factor this into your panel ventilation design.
Additional Specifications
Scalar (V/f)
Vector
AC-powered
Buying Guide
- Confirm the exact model, part number, and specifications before ordering.
- Ensure compatibility with your current machinery or control systems.
- Reach out via sale@etowonauto.com or +8617859788089 for technical assistance.
- Review delivery options, lead times, and shipping requirements.
- Follow manufacturer instructions and best practices during installation.
Shipping And Return
In-stock items are typically dispatched the same business day. For products not currently in stock, dispatch times may vary based on availability. International shipping is available, and shipping costs are calculated according to destination, weight, and carrier selection.
Returns are accepted within 30 days of receipt, provided items are unused and in original condition. Return shipping costs are the responsibility of the customer. Please contact us before returning any item to receive return authorization.
For more details, please review our Shipping & Return Policy.

3500/61-05-CN Temperature Monitor Module | Bently Nevada
3500/22-01-02-CN TDI Module Bently Nevada
Bently Nevada 3500/42-04-00 | Seismic Monitor
-
Fast Shipping
Original industrial automation parts available for prompt shipment worldwide.
-
Easy Returns
30-day return support with a 12-month warranty for reliable after-sales protection.
-
24/7 support
Responsive professional support to help maintain stable and efficient operations.
-
Genuine & Original
100% authentic, sourced directly from trusted industrial automation manufacturers.
Technical & Buying Guide
-
Can PLC and DCS Integration Prevent Chemical Plant Accidents?
This technical article examines how Programmable Logic Controllers (PLC) and Distributed Control Systems (DCS) enhanc...
-
What Role Do PLC and DCS Systems Play in Smart Mining?
This technical article examines how modern PLC and DCS integration is revolutionizing smart mining operations through...
-
Can Smart Control Systems Solve Modern Energy Challenges?
The convergence of PLC and DCS systems with AI and IoT is revolutionizing power grid management, enabling predictive ...
-
How Do PLCs and DCS Enable Flexible Automation in Manufacturing?
This article examines how programmable logic controllers (PLCs) and distributed control systems (DCS) enable flexible...
-
Why Integrate Smart Sensors with Your PLC System Now?
This technical article examines the integration of PLCs and smart sensors in industrial automation, providing enginee...
-
How Do PLCs Improve Battery Manufacturing Precision?
Technical engineering guide examining PLC applications in battery production lines, including programming strategies ...