Transform your home with the latest multi-electronics solutions, from intelligent lighting to vOptimize your operations with the Bently Nevada 3500 Monitoring System, offering real-time vibration and machinery condition monitoring to prevent failures and maximize uptime.oice-controlled devices all designed to make life easier, safer, and more connected.
SKU:CC-PDOD51
Honeywell CC-PDOD51 32-Channel Digital Output
Manufacturer: Honeywell
Product No.: CC-PDOD51
Product Type: Output Module
Product Origin: USA
Payment:T/T, Western Union
Weight: 800g
Shipping port: Xiamen
Warranty: 12 months
Share
- Fast Delivery
- 24/7 Support
- Quality Assurance
Description
Honeywell CC-PDOD51: 32-Channel Sink Digital Output
The Honeywell CC-PDOD51 delivers high-density digital switching for industrial applications.
Output Specifications
- Brand: Honeywell
- Model: CC-PDOD51
- Type: Series C Digital Output Module
- Channels: 32 digital outputs
- Output Type: SINK (Open Drain)
- Load Voltage: 30 VDC maximum
- Load Current: 0.1 A per channel max
- On-State Voltage: 0 VDC at 0.1A load
- Off-State Voltage: 24 VDC typical
- Off-State Leakage: 100 µA maximum
- Turn-On/Off Time: 10 ms maximum
Isolation & Protection
- Galvanic Isolation: 1000 VAC RMS system-to-field
- Field Power: User supplied external 24V
- Bussed Output: Common return for group wiring
- Coating: Conformal coated for harsh environments
- Redundancy Gap: 0ms switchover (redundant systems)
Compatible IOTA
- IOTA Model: CC-TDOD51
- Configuration: Non Redundant
- IOTA Position: 9 (standard mounting)
Environmental Ratings
- Temperature: -40°C to +70°C operating
- Storage: -55°C to +85°C
- Humidity: 5% to 95% non-condensing
- Vibration: IEC 60068-2-6 compliant
- EMC: IEC 61000-6-2, IEC 61000-6-4
Physical Characteristics
- Weight: 0.9kg (1.98 lbs)
- Terminals: Via CC-TDOD51 IOTA
- LED Indicators: Per channel status on IOTA
- Mounting: Series C I/O rack
- Coating: Conformal coated circuit boards
Frequently Asked Questions
Q: What external power supply do I need for the CC-PDOD51?
A: The CC-PDOD51 requires a user-supplied 24V DC field power source. Connect this to the CC-TDOD51 IOTA terminals. The module isolates this field power from the system backplane.
Q: Can I drive 24V DC relays with the 0.1A output?
A: Yes. Most industrial relays draw 20-50mA at 24V. The CC-PDOD51 easily drives them. Check your specific relay coil current stays under 100mA.
Q: What does 0ms gap mean for redundancy?
A: In redundant configurations, the CC-PDOD51 switches outputs with zero interruption. The backup takes over immediately with no current gap to field devices.
Additional Specifications
Scalar (V/f)
Vector
AC-powered
Buying Guide
- Confirm the exact model, part number, and specifications before ordering.
- Ensure compatibility with your current machinery or control systems.
- Reach out via sale@etowonauto.com or +8617859788089 for technical assistance.
- Review delivery options, lead times, and shipping requirements.
- Follow manufacturer instructions and best practices during installation.
Shipping And Return
In-stock items are typically dispatched the same business day. For products not currently in stock, dispatch times may vary based on availability. International shipping is available, and shipping costs are calculated according to destination, weight, and carrier selection.
Returns are accepted within 30 days of receipt, provided items are unused and in original condition. Return shipping costs are the responsibility of the customer. Please contact us before returning any item to receive return authorization.
For more details, please review our Shipping & Return Policy.

3500/61-05-CN Temperature Monitor Module | Bently Nevada
3500/22-01-02-CN TDI Module Bently Nevada
Bently Nevada 3500/42-04-00 | Seismic Monitor
-
Fast Shipping
Original industrial automation parts available for prompt shipment worldwide.
-
Easy Returns
30-day return support with a 12-month warranty for reliable after-sales protection.
-
24/7 support
Responsive professional support to help maintain stable and efficient operations.
-
Genuine & Original
100% authentic, sourced directly from trusted industrial automation manufacturers.
Technical & Buying Guide
-
Stop 68% of DCS Faults with Proven Transmitter Matching Rules?
This article presents field-verified solutions for optimizing communication between Rosemount transmitters and Emerso...
-
What Does Poor PLC Backup Cost Your Paper Plant?
This technical article presents quantified backup and recovery standards for GE Fanuc RX7i PLCs in high-capacity pape...
-
Why Do 42% of Offshore DCS Downtime Events Trace to Power Modules?
This technical analysis examines the root causes of Allen‑Bradley power module failures in offshore control cabi...
-
Can Layered PLC Fix Chemical Batch Failures?
This technical article presents field-validated ABB AC800M configuration strategies for high-stability fine chemical ...
-
How to Select GE Fanuc 90-30 Spare Parts for Hot Rolling Mills?
This article provides a technical guide for selecting and managing GE Fanuc Series 90-30 PLC spare parts in meta...
-
How Does Bently Nevada 3500 Reduce Unplanned Turbine Trips?
This technical article analyzes the quantitative value of the Bently Nevada 3500 TSI system in thermal power shaft pr...