Transform your home with the latest multi-electronics solutions, from intelligent lighting to vOptimize your operations with the Bently Nevada 3500 Monitoring System, offering real-time vibration and machinery condition monitoring to prevent failures and maximize uptime.oice-controlled devices all designed to make life easier, safer, and more connected.
SKU:IS200VAICH1C
GE IS200VAICH1C Mark VI Analog I/O Board | 24-Channel VAIC Processor
Manufacturer: General Electric
Product No.: IS200VAICH1C
Product Type: I/O Board
Product Origin: USA
Payment:T/T, Western Union
Weight: 500g
Shipping port: Xiamen
Warranty: 12 months
Share
- Fast Delivery
- 24/7 Support
- Quality Assurance
Description
Product Overview
The GE IS200VAICH1C is a VME Analog Input/Output (VAIC) board for the Mark VI turbine control system. This versatile board supports both TMR (triple modular redundant) and Simplex configurations for gas and steam turbines. It accepts 20 analog inputs and controls 4 analog outputs, making it essential for turbine monitoring and control applications.
Core Functionality
The VAIC board converts analog field signals to digital values for transmission over the VME backplane to the VCMI board and controller. For outputs, it converts digital values to analog currents (4-20mA or 0-200mA) and drives them to field devices. In TMR configurations, input signals fan out to three racks (R, S, T) with automatic median voting on outputs. If one VAIC fails, it is removed from the output circuit while the remaining two maintain correct current output. The board also executes gas turbine compressor stall detection at 200Hz using pressure transducer inputs.
Technical Specifications
| Parameter | Value |
| Part Number | IS200VAICH1C |
| Manufacturer | General Electric |
| Series | Mark VI |
| Product Type | Analog I/O Board (VAIC) |
| Total Channels | 24 (20 AI, 4 AO) |
| Analog Inputs | 20 (voltage or 4-20mA) |
| Analog Outputs | 4 (4-20mA / 0-200mA configurable) |
| Configuration Support | TMR and Simplex |
| Stall Detection | 200 Hz (2 or 3 transducer algorithms) |
| Max Output Load (20mA) | 500Ω (1000ft #18 wire) |
| Compatible Terminal Boards | TBAIH1B or earlier, DTAI (all revisions) |
| PCB Coating | Conformal Coating |
| Functional Revision | C |
| Weight | Approx. 0.5 kg (1.1 lbs) |
| Reference Manual | GEH-6421 |
| Country of Origin | USA |
Compatibility
The IS200VAICH1C belongs to the original VAIC generation (versions up to and including VAICH1C). For proper operation, use terminal board TBAIH1B or earlier, or any revision of DTAI. This generation supports up to 500Ω load resistance at 20mA output with 1000ft of #18 wire. For newer VAICH1D and subsequent releases requiring higher load resistance (up to 800Ω), use TBAIH1C or later, or any STAI revision. Note that VAICH1C is not compatible with newer terminal board generations.
Installation Guide
Power down the VME processor rack before installation. Slide the IS200VAICH1C into the rack slot, then push the top and bottom levers simultaneously to seat the edge connectors fully. Tighten the captive screws at the top and bottom of the front panel. Connect the terminal board cables to the rear connectors. For TMR systems, ensure all three VAIC boards (R, S, T) are installed with matching firmware revisions. Verify the terminal board ID chip is read correctly during power-up.
Engineering Advantages
The IS200VAICH1C provides 24 channels of analog I/O with support for both TMR and Simplex architectures. The median voting scheme on TMR outputs ensures continued operation through single-channel failures. Built-in compressor stall detection at 200Hz enables rapid turbine protection response. Diagnostic features include hardware limit checking, configurable system limits, TMR signal deviation detection, and ID chip verification. The conformal coating protects against moisture and contamination in harsh turbine environments. LEDs provide immediate visual status (flashing green for RUN, solid red for FAIL, steady orange for diagnostic alarm). At approximately 0.5 kg (1.1 lbs), the board is lightweight for easy handling during installation.
Technical FAQs
Q1: Difference between VAICH1C and VAICH1D?
A1: VAICH1C supports 500Ω load at 20mA. VAICH1D supports 800Ω with 18V at terminals. VAICH1C requires TBAIH1B or earlier.
Q2: Can this board work in Simplex mode?
A2: Yes. The IS200VAICH1C supports both Simplex and TMR configurations with full functionality.
Q3: What does compressor stall detection do?
A3: Executes at 200Hz using pressure transducers. Trip signal initiates fuel shut-off valve closure for turbine protection.
Additional Specifications
- Green
Scalar (V/f)
Vector
AC-powered
Buying Guide
- Confirm the exact model, part number, and specifications before ordering.
- Ensure compatibility with your current machinery or control systems.
- Reach out via sale@etowonauto.com or +8617859788089 for technical assistance.
- Review delivery options, lead times, and shipping requirements.
- Follow manufacturer instructions and best practices during installation.
Shipping And Return
In-stock items are typically dispatched the same business day. For products not currently in stock, dispatch times may vary based on availability. International shipping is available, and shipping costs are calculated according to destination, weight, and carrier selection.
Returns are accepted within 30 days of receipt, provided items are unused and in original condition. Return shipping costs are the responsibility of the customer. Please contact us before returning any item to receive return authorization.
For more details, please review our Shipping & Return Policy.

3500/61-05-CN Temperature Monitor Module | Bently Nevada
3500/22-01-02-CN TDI Module Bently Nevada
Bently Nevada 3500/42-04-00 | Seismic Monitor
-
Fast Shipping
Original industrial automation parts available for prompt shipment worldwide.
-
Easy Returns
30-day return support with a 12-month warranty for reliable after-sales protection.
-
24/7 support
Responsive professional support to help maintain stable and efficient operations.
-
Genuine & Original
100% authentic, sourced directly from trusted industrial automation manufacturers.
Technical & Buying Guide
-
Can Emerson DeltaV DCS Cards Optimize Chemical Safety Loops?
This technical article examines how Emerson DeltaV DCS card upgrades address legacy control limitations in chemical p...
-
Is Partial CNC Board Replacement Better Than a Full System Upgrade?
This technical article examines the dominance of GE Fanuc CNC hardware in heavy-duty automation, supported by field d...
-
Can Genuine PLC Modules Cut DCS Downtime 60%?
This article examines how genuine Allen-Bradley PLC module replacement strategies directly reduce unplanned DCS downt...
-
Is Your GE Fanuc PLC Talking to ABB DCS?
This article reveals how cross-system data silos between GE Fanuc PLC and ABB DCS cause 8–15% production losses in pr...
-
Can Integrated PLC-DCS-TSI Fix Data Silos?
Most industrial digital twins remain static visualization tools because discrete control, process automation, and con...
-
How to Cut Power Plant Outages with ABB and GE Fanuc Retrofits?
This technical article outlines a data-driven approach to modernizing power plant control systems using a hybrid ABB ...