Transform your home with the latest multi-electronics solutions, from intelligent lighting to vOptimize your operations with the Bently Nevada 3500 Monitoring System, offering real-time vibration and machinery condition monitoring to prevent failures and maximize uptime.oice-controlled devices all designed to make life easier, safer, and more connected.
SKU:IC660ELB912
GE IC660ELB912 Genius Network Interface Board
Manufacturer: General Electric
Product No.: IC660ELB912
Product Type: Interface Board
Product Origin: USA
Payment:T/T, Western Union
Weight: 1360g
Shipping port: Xiamen
Warranty: 12 months
Share
- Fast Delivery
- 24/7 Support
- Quality Assurance
Description
MICROGENI DAUGHTERBOARD | IC660ELB912 GENIUS I/O
The GE Fanuc IC660ELB912 is a µGENI Network Interface Board from the Genius I-O series. This daughterboard attaches to single-slot or dual-slot PCIM cards. It enables host control of remote I/O over the Genius I/O bus. The IC660ELB912 handles all data transfers between host and bus. This frees the host for other tasks. Power requirement: 5 Volts DC at 400 milliamps. Weight: 3 lb (1.36 kg).
TECHNICAL SPECIFICATIONS
- Brand: GE Fanuc / Emerson Automation
- Model: IC660ELB912
- Product Type: MicroGENI Daughterboard
- Compatible PCIM: IC660ELB921 (single-slot), IC660ELB922 (dual-channel)
- Power Requirement: 5 VDC, 400 mA
- Current Consumption: 1.0 A (single PCIM), 1.5 A (dual PCIM)
- Memory Requirement: 16 KB host memory per board
- Shared RAM: 16 KB
- Supported Devices: 30 per daughterboard
- Communication Rates: 38.4K, 76.8K, 153.6K standard, 153.6K extended
- Temperature Range: 0 to 60 °C (operating)
- Storage Temperature: -40 to 70 °C
- Humidity: 5 to 95% non-condensing
- Operating Altitude: 40,000 feet
- Shock Rating: 5 G, 10 ms duration
- Weight: 3 lb (1.36 kg)
PACKAGE INCLUDES
- 1 x GE Fanuc IC660ELB912 MicroGENI Daughterboard
- 1 x Installation Guide
- Secure FedEx, UPS, or DHL shipping
FAQ
-
Q: Which PCIM cards work with this daughterboard?
A: It works with single-slot IC660ELB921 and dual-channel IC660ELB922 PCIM cards. -
Q: How many devices can one daughterboard manage?
A: It manages up to 30 bus devices with 16 KB shared memory. -
Q: What clearance do I need during installation?
A: Maintain at least 1/8 inch space from other components for proper airflow.
Additional Specifications
- Black
- Green
- AC-powered
- DC-powered
- Modular
Scalar (V/f)
Vector
AC-powered
Buying Guide
- Confirm the exact model, part number, and specifications before ordering.
- Ensure compatibility with your current machinery or control systems.
- Reach out via sale@etowonauto.com or +8617859788089 for technical assistance.
- Review delivery options, lead times, and shipping requirements.
- Follow manufacturer instructions and best practices during installation.
Shipping And Return
In-stock items are typically dispatched the same business day. For products not currently in stock, dispatch times may vary based on availability. International shipping is available, and shipping costs are calculated according to destination, weight, and carrier selection.
Returns are accepted within 30 days of receipt, provided items are unused and in original condition. Return shipping costs are the responsibility of the customer. Please contact us before returning any item to receive return authorization.
For more details, please review our Shipping & Return Policy.

3500/61-05-CN Temperature Monitor Module | Bently Nevada
3500/22-01-02-CN TDI Module Bently Nevada
Bently Nevada 3500/42-04-00 | Seismic Monitor
-
Fast Shipping
Original industrial automation parts available for prompt shipment worldwide.
-
Easy Returns
30-day return support with a 12-month warranty for reliable after-sales protection.
-
24/7 support
Responsive professional support to help maintain stable and efficient operations.
-
Genuine & Original
100% authentic, sourced directly from trusted industrial automation manufacturers.
Technical & Buying Guide
-
Can Anti-Interference Hardware End 38% of Automation Downtime?
Field data from chemical, wind, and automotive plants proves that industrial hardware with full IEC 61000-4 EMC certi...
-
How Does Full-Lifecycle Management Optimize PLC and DCS Assets?
Traditional industrial asset management relies on manual logging and reactive troubleshooting, causing 15–20% annual ...
-
Can an Integrated Spare Chain Slash Downtime?
Unplanned equipment failures cost Chinese factories ¥636,000 per hour. Traditional cross-border spare procurement tak...
-
Why Do 30% of Automation Upgrades Fail Due to Integration Gaps?
This technical article explains how digital-intelligent fusion overcomes fragmented workshop operations using industr...
-
Why Do Heavy Industries Trust GE Fanuc PLC and DCS Systems?
This article examines how GE Fanuc core components solve reliability gaps in heavy-load factory automation. It covers...
-
How Does Bently Nevada Predict Failures 180 Days in Advance?
Standard PLC and DCS systems often miss early vibration anomalies in rotating machinery, leading to 68% of sudden mec...
