Transform your home with the latest multi-electronics solutions, from intelligent lighting to vOptimize your operations with the Bently Nevada 3500 Monitoring System, offering real-time vibration and machinery condition monitoring to prevent failures and maximize uptime.oice-controlled devices all designed to make life easier, safer, and more connected.
SKU:IC200CHS211
GE IC200CHS211 Versamax Relay Module
Manufacturer: General Electric
Product No.: IC200CHS211
Product Type: Relay Interface Base
Product Origin: USA
Payment:T/T, Western Union
Weight: 200g
Shipping port: Xiamen
Warranty: 12 months
Share
- Fast Delivery
- 24/7 Support
- Quality Assurance
Description
GE Fanuc Versamax IC200CHS211 Relay Interface Base
The IC200CHS211 is a 16-point relay interface base from the GE Fanuc Versamax series. This relay base provides electrical isolation for safe circuit separation in industrial control systems. It features replaceable relays and 8A fuses for easy maintenance.
Technical Specifications
- Brand: GE Fanuc
- Series: Versamax
- Model: IC200CHS211
- I/O Points: 16 fused channels
- Voltage: 24V DC control
- Fuse Rating: 8A per point (replaceable)
- Wire Gauge: 14 AWG recommended
- Temperature Range: 0°C to 60°C
- Humidity: 95% non-condensing maximum
- Certifications: UL, CE, ATEX
Key Features
- Replaceable relays for easy maintenance
- Electrical isolation between circuits
- Shock and vibration resistant
- Visual status LEDs for all 16 points
- Each channel fused at 8A with replaceable fuses
- Requires 24V DC output modules (0.5A rating)
Installation Guide
- Simple DIN rail mounting for quick installation
- Requires 24V DC output modules with 0.5A rating
- Each channel features status LED indicators
- Use 14 AWG wire for optimal connections
- Maintain operating temperature below 60°C
Compatibility
- Works with all Versamax I/O modules
- Supports systems with up to 256 I/O points expansion
- Compatible with 24V DC output modules
Technical Documentation
📥 Download Product Datasheet PDF
FAQ
1. What is the part number for this relay base?
The part number is IC200CHS211.
2. How many I/O points does the IC200CHS211 have?
It features 16 fused channels with replaceable 8A fuses and status LEDs per point.
3. What are the safety certifications for this base?
The IC200CHS211 is certified with UL, CE, and ATEX standards for industrial use.
Additional Specifications
- Black
Scalar (V/f)
Vector
AC-powered
Buying Guide
- Confirm the exact model, part number, and specifications before ordering.
- Ensure compatibility with your current machinery or control systems.
- Reach out via sale@etowonauto.com or +8617859788089 for technical assistance.
- Review delivery options, lead times, and shipping requirements.
- Follow manufacturer instructions and best practices during installation.
Shipping And Return
In-stock items are typically dispatched the same business day. For products not currently in stock, dispatch times may vary based on availability. International shipping is available, and shipping costs are calculated according to destination, weight, and carrier selection.
Returns are accepted within 30 days of receipt, provided items are unused and in original condition. Return shipping costs are the responsibility of the customer. Please contact us before returning any item to receive return authorization.
For more details, please review our Shipping & Return Policy.

3500/61-05-CN Temperature Monitor Module | Bently Nevada
3500/22-01-02-CN TDI Module Bently Nevada
Bently Nevada 3500/42-04-00 | Seismic Monitor
-
Fast Shipping
Original industrial automation parts available for prompt shipment worldwide.
-
Easy Returns
30-day return support with a 12-month warranty for reliable after-sales protection.
-
24/7 support
Responsive professional support to help maintain stable and efficient operations.
-
Genuine & Original
100% authentic, sourced directly from trusted industrial automation manufacturers.
Technical & Buying Guide
-
How Can Modern Automation Reduce Power Plant Downtime?
Discover power plant control system upgrade strategies using PLC & DCS. Real case studies, 24/7 support, and expe...
-
How to Extend DCS and PLC Lifespan With Smart Maintenance?
Effective maintenance of DCS and PLC systems is essential for maximizing uptime and efficiency in industrial automati...
-
Why Combine DCS with Edge Controllers in Oil & Gas?
Expert guide on selecting and maintaining PLC and DCS systems for oil & gas automation. Covers environmental fact...
-
How Does PLC-DCS Integration Boost Power Plant Efficiency?
This article explores strategic approaches to integrating PLC and DCS systems in power plants, featuring real-world c...
-
Are Legacy PLCs Putting Your Petrochemical Operations at Risk?
This article explores the critical role of troubleshooting and optimization in maintaining PLC and DCS reliability wi...
-
What Causes DCS Failures in Power Plants and How to Fix Them?
This article provides a comprehensive guide to managing Distributed Control System (DCS) failures in power generation...