Transform your home with the latest multi-electronics solutions, from intelligent lighting to vOptimize your operations with the Bently Nevada 3500 Monitoring System, offering real-time vibration and machinery condition monitoring to prevent failures and maximize uptime.oice-controlled devices all designed to make life easier, safer, and more connected.
SKU:IC697MDL940
GE Fanuc IC697MDL940 Series 90-70 16-Channel Relay Output Module
Manufacturer: General Electric
Product No.: IC697MDL940
Product Type: Relay Output Module
Product Origin: USA
Payment:T/T, Western Union
Weight: 150g
Shipping port: Xiamen
Warranty: 12 months
Share
- Fast Delivery
- 24/7 Support
- Quality Assurance
Description
Product Overview
The GE Fanuc IC697MDL940 is a versatile 16-channel relay output module engineered for the Series 90-70 Programmable Logic Controller system. This module provides a flexible interface between the PLC backplane and external field devices, utilizing a combination of eight Form C (Normally Open/Normally Closed) and eight Form A (Normally Open) contacts. Designed for high reliability in complex switching applications, the IC697MDL940 supports a wide range of voltages, making it an essential component for controlling motors, valves, and indicators in diverse industrial settings.
Technical Specifications
| Feature | Specification |
|---|---|
| Model Number | IC697MDL940 (Series 90-70) |
| Output Channels | 16 Total (8 Form C, 8 Form A) |
| Rated Voltage (AC) | 120/240 VAC (Range: 5-265 VAC) |
| Rated Voltage (DC) | 5/24/125 VDC (Range: 5-30 VDC) |
| Maximum Load | 2.0 Amps per contact |
| Module Weight | Approximately 150 g (0.33 lbs) |
| Backplane Isolation | 1500 Volts |
| Power Dissipation | 5.5 Watts |
Core Technical Advantages
Mixed Contact Configuration
The IC697MDL940 distinguishes itself by offering both Form A and Form C relay types within a single module slot. This hybrid design allows engineers to handle both basic switching and changeover logic simultaneously, reducing the total number of modules required in the PLC rack.
Superior Inrush Handling
Built to survive the demands of inductive loads, the module features silver-alloy contacts capable of managing an inrush current of up to 15A for 50ms. This ensures long-term contact durability when driving solenoids or small motor starters that exhibit high initial current spikes.
High-Voltage Isolation Protection
To protect the sensitive Series 90-70 CPU and backplane, the IC697MDL940 provides 1500V isolation. This barrier prevents field-side electrical surges from migrating to the control logic, significantly increasing overall system uptime and safety.
Installation & Maintenance
- Mechanical Keying: Utilize the module's unique keying feature to prevent accidental insertion into the wrong rack slot during field maintenance.
- Fuse Protection: Each channel is protected by a 3A fuse. Always verify field load requirements do not exceed the 2.0A continuous rating to prevent nuisance blowing.
- Contact Lifespan: For high-frequency switching (exceeding 20 cycles per minute), consider external snubbers for inductive loads to extend the silver-alloy contact life beyond the standard 90,000-hour MTBF.
Engineering Advantages
The IC697MDL940 is optimized for rugged environments, maintaining full functionality across an operating temperature range of –25°C to 70°C. Despite its lightweight design of only 150 g, the module is built for industrial resilience. Its low internal power dissipation (5.5W) minimizes heat buildup within the PLC enclosure, while the 10mA minimum load capability ensures compatibility with modern electronic relay coils.
Technical FAQs
Q1: Can I mix AC and DC voltages on the same IC697MDL940 module?
A1: Yes. Relays are dry contacts, meaning you can switch different voltages on different channels, provided you observe group load limits and ensure proper wiring isolation between circuits.
Q2: What is the difference between Form A and Form C contacts on this module?
A2: The module provides 8 Form A contacts (Normally Open) and 8 Form C contacts (Single Pole Double Throw). Form C contacts provide both a Normally Open and a Normally Closed terminal for every common wire.
Q3: Is this module hot-swappable?
A3: Standard Series 90-70 procedures require the system power to be off when removing or inserting modules to prevent backplane arcing and ensure data integrity.
Additional Specifications
Scalar (V/f)
Vector
AC-powered
Buying Guide
- Confirm the exact model, part number, and specifications before ordering.
- Ensure compatibility with your current machinery or control systems.
- Reach out via sale@etowonauto.com or +8617859788089 for technical assistance.
- Review delivery options, lead times, and shipping requirements.
- Follow manufacturer instructions and best practices during installation.
Shipping And Return
In-stock items are typically dispatched the same business day. For products not currently in stock, dispatch times may vary based on availability. International shipping is available, and shipping costs are calculated according to destination, weight, and carrier selection.
Returns are accepted within 30 days of receipt, provided items are unused and in original condition. Return shipping costs are the responsibility of the customer. Please contact us before returning any item to receive return authorization.
For more details, please review our Shipping & Return Policy.

3500/61-05-CN Temperature Monitor Module | Bently Nevada
3500/22-01-02-CN TDI Module Bently Nevada
Bently Nevada 3500/42-04-00 | Seismic Monitor
-
Fast Shipping
Original industrial automation parts available for prompt shipment worldwide.
-
Easy Returns
30-day return support with a 12-month warranty for reliable after-sales protection.
-
24/7 support
Responsive professional support to help maintain stable and efficient operations.
-
Genuine & Original
100% authentic, sourced directly from trusted industrial automation manufacturers.
Technical & Buying Guide
-
How does hierarchical control raise factory OEE from 64% to 82%?
This article explains how hierarchical cloud-edge collaborative control replaces fragmented industrial architectures....
-
Can DCS Intelligent Regulation Fix Thermal Power Energy Imbalance?
This article explains how intelligent DCS regulation with MPC and cloud-based control solves energy-production imbala...
-
Can Continuous Automation Iteration Cut Factory Costs by 18-25%?
Static industrial control systems create hidden annual cost increases of 18-25%. Phased PLC and DCS program iteration...
-
Can Anti-Interference Hardware End 38% of Automation Downtime?
Field data from chemical, wind, and automotive plants proves that industrial hardware with full IEC 61000-4 EMC certi...
-
How Does Full-Lifecycle Management Optimize PLC and DCS Assets?
Traditional industrial asset management relies on manual logging and reactive troubleshooting, causing 15–20% annual ...
-
Can an Integrated Spare Chain Slash Downtime?
Unplanned equipment failures cost Chinese factories ¥636,000 per hour. Traditional cross-border spare procurement tak...