Skip to content
Automation parts, worldwide supply
Skip to product information
1 of 3

SKU:IC693MDL930

GE Fanuc IC693MDL930 8-Channel Relay Output Module

In stock (11 units), ready to be shipped
  • Manufacturer: General Electric

  • Product No.: IC693MDL930

  • Product Type: Discrete Output Module

  • Product Origin: USA

  • Payment:T/T, Western Union

  • Weight: 350g

  • Shipping port: Xiamen

  • Warranty: 12 months

30-Day Return Policy · 12-Month Warranty
  • Fast Delivery
  • 24/7 Support
  • Quality Assurance

Description

Product Overview

The GE Fanuc IC693MDL930 is an 8-channel isolated relay discrete output module designed for the Series 90-30 programmable logic controller (PLC) system. This versatile module features eight independent, normally open (Form A) relay circuits that allow the PLC to interface with external actuators, solenoids, motor starters, and pilot indicators. By providing complete electrical isolation between internal logic and external field wiring, the IC693MDL930 enables seamless, concurrent control of both AC and DC industrial loads from a single PLC rack assembly.

Technical Configuration

Core Technical Advantages

The IC693MDL930 utilizes high-reliability mechanical relays that provide independent power isolation for each of its eight output points. It handles a wide range of switching voltages—up to 30 VDC or 250 VAC—offering great application flexibility. The modular design drops tool-less swap-out times dramatically, plugging directly into any standard I/O slot of a Series 90-30 baseplate. Low internal power consumption preserves system energy efficiency while minimizing thermal generation within local panel layouts.

Technical Specifications

Model Designation IC693MDL930
Product Series GE Fanuc Series 90-30 PLC
Output Type Discrete Isolated Relay (Form A - Normally Open)
Channel Count 8 independent isolated channels
Nominal Output Voltage 24 VDC / 120 VAC / 240 VAC
Operating Voltage Range 5 to 30 VDC / 5 to 250 VAC
Max Continuous Current 2 A per point (maximum resistive rating)
Maximum Inrush Current 5 A per channel (maximum spike duration)
Response Time 15 ms maximum activation/deactivation delay
Operating Temperature 0°C to +50°C
Net Weight 0.35 kg

Installation Guide

Mechanical Mounting and Slot Insertion

Turn off the main rack power before installing the module. Align the top hook of the IC693MDL930 housing with the retention slot on the Series 90-30 baseplate. Pivot the module downward until the rear bus connector snaps securely into the backplane, then tighten the bottom securing screw.

Field Terminal Blocks and Wiring

Swing open the front terminal door to access the screw connectors. Connect individual field circuits using up to 14 AWG wire leads. Because each channel is fully isolated, you can mix distinct AC and DC supply loops across adjacent terminals without introducing cross-talk or short circuits.

Surge Suppression for Inductive Loads

When switching inductive loads like relay coils, magnetic starters, or solenoids, install external noise suppression components. Wire a commutation diode across DC circuits, or snap a metal oxide varistor (MOV) network across AC loads to suppress voltage arcs and extend mechanical relay life.

Engineering Advantages

Isolated Multi-Voltage Management

The channel-to-channel isolation on the IC693MDL930 eliminates the need for separate DC and AC output cards. Engineers can control high-current 240 VAC mechanisms and low-signal 24 VDC indication lines on a single hardware block, optimizing total system layout costs.

Industrial Protection and Visibility

The module includes a removable front terminal block, allowing maintenance teams to swap module electronics without disconnecting field wires. Front-facing LED indicators display the real-time ON/OFF state of each logic channel, providing instant diagnostic visibility for field technicians.

Technical FAQs

Q1: Can I use the IC693MDL930 to switch extremely low signal current lines?

A1: Yes, the contact resistance accommodates signals down to 5V. However, mechanical contacts require a minimum wetting current (typically 10 mA) to reliably break through microscopic surface oxidation over long periods of operation.

Q2: What happens if an output circuit demands more than the 5 A peak inrush rating?

A2: Exceeding the inrush parameters can cause contact arcing, which may pit or weld the physical relay contacts closed. For large loads or motor coils with severe surge cycles, use this module to switch an external interposing contactor.

Q3: Why is the module's response time listed at 15 ms compared to electronic solid-state cards?

A3: Solid-state cards switch using transistors or triacs almost instantly, whereas the IC693MDL930 relies on physical mechanical movement to snap the relay arm into place, which requires a brief 15 ms activation delay.

🏷️ Tags: Discrete Output Module

Scalar (V/f)

Vector

AC-powered

  • Confirm the exact model, part number, and specifications before ordering.
  • Ensure compatibility with your current machinery or control systems.
  • Reach out via sale@etowonauto.com or +8617859788089 for technical assistance.
  • Review delivery options, lead times, and shipping requirements.
  • Follow manufacturer instructions and best practices during installation.

In-stock items are typically dispatched the same business day. For products not currently in stock, dispatch times may vary based on availability. International shipping is available, and shipping costs are calculated according to destination, weight, and carrier selection.

Returns are accepted within 30 days of receipt, provided items are unused and in original condition. Return shipping costs are the responsibility of the customer. Please contact us before returning any item to receive return authorization.

For more details, please review our Shipping & Return Policy.

View Product Details

ENSURE RELIABLE MACHINERY PERFORMANCE

Transform your home with the latest multi-electronics solutions, from intelligent lighting to vOptimize your operations with the Bently Nevada 3500 Monitoring System, offering real-time vibration and machinery condition monitoring to prevent failures and maximize uptime.oice-controlled devices all designed to make life easier, safer, and more connected.