Transform your home with the latest multi-electronics solutions, from intelligent lighting to vOptimize your operations with the Bently Nevada 3500 Monitoring System, offering real-time vibration and machinery condition monitoring to prevent failures and maximize uptime.oice-controlled devices all designed to make life easier, safer, and more connected.
SKU:IC670MDL331
GE Fanuc IC670MDL331 Output Module | 8 Channel AC 120V
Manufacturer: General Electric
Product No.: IC670MDL331
Product Type: Discrete Output Module
Product Origin: USA
Payment:T/T, Western Union
Weight: 500g
Shipping port: Xiamen
Warranty: 12 months
Share
- Fast Delivery
- 24/7 Support
- Quality Assurance
Description
GE Fanuc Discrete Output Module IC670MDL331
The GE Fanuc IC670MDL331 is an 8-channel AC output module for industrial control systems. It switches 85-132V AC loads with 2A per channel capacity and includes fuse protection for reliable operation.
Technical Specifications
- Brand & Model: GE Fanuc IC670MDL331
- Module Type: 8-Channel AC Output
- Output Channels: 8 (grouped as 4 pairs)
- Output Voltage: 85–132 VAC, 47–63 Hz
- Inrush Current: 20 A max (1 cycle)
- Output Protection: 3 A slow-blow fuse per channel
- Isolation: 250 VAC continuous / 1500 VAC for 1 min
- Voltage Drop: 3 V maximum
- Leakage Current: 2 mA @ 120 VAC
- Snubber Circuit: 47.5 Ω + 0.022 μF per output
- Module Weight: 0.5 kg
Key Features
- 8 independent AC output channels for switching loads
- 2A per channel capacity for driving motors, solenoids, and heaters
- Individual 3A fuse protection on each output
- Fast 1ms response time for precise control
- Built-in snubber circuits for inductive load protection
- High isolation (1500 VAC) for system safety
Shipping Information
- 1x IC670MDL331 output module
- Approximate shipping weight: 0.8 kg
- Secure protective packaging
- Shipped via FedEx, UPS, or DHL
FAQ
-
What type of loads can this module control?
It controls 120V AC inductive and resistive loads such as motor starters, solenoid valves, contactors, and heating elements. -
What happens if a fuse blows?
The affected channel stops operating. Replace with an identical 3A slow-blow fuse (5×20 mm) after clearing the fault. -
What is the purpose of the snubber circuit?
It suppresses voltage spikes when switching inductive loads, protecting the output triac from damage.
Additional Specifications
- Black
Scalar (V/f)
Vector
AC-powered
Buying Guide
- Confirm the exact model, part number, and specifications before ordering.
- Ensure compatibility with your current machinery or control systems.
- Reach out via sale@etowonauto.com or +8617859788089 for technical assistance.
- Review delivery options, lead times, and shipping requirements.
- Follow manufacturer instructions and best practices during installation.
Shipping And Return
In-stock items are typically dispatched the same business day. For products not currently in stock, dispatch times may vary based on availability. International shipping is available, and shipping costs are calculated according to destination, weight, and carrier selection.
Returns are accepted within 30 days of receipt, provided items are unused and in original condition. Return shipping costs are the responsibility of the customer. Please contact us before returning any item to receive return authorization.
For more details, please review our Shipping & Return Policy.

3500/61-05-CN Temperature Monitor Module | Bently Nevada
3500/22-01-02-CN TDI Module Bently Nevada
Bently Nevada 3500/42-04-00 | Seismic Monitor
-
Fast Shipping
Original industrial automation parts available for prompt shipment worldwide.
-
Easy Returns
30-day return support with a 12-month warranty for reliable after-sales protection.
-
24/7 support
Responsive professional support to help maintain stable and efficient operations.
-
Genuine & Original
100% authentic, sourced directly from trusted industrial automation manufacturers.
Technical & Buying Guide
-
How to Integrate Cross-Brand DCS and PLC?
This guide delivers field-verified engineering methods for integrating multi-brand DCS and PLC systems. It addresses ...
-
Can Genuine OEM Components Cut Your Automation Downtime by 90%?
This technical brief examines the financial and operational impact of non-genuine automation spare parts across ...
-
How to Solve PLC and DCS Faults in Industrial Automation?
Unplanned downtime in manufacturing is frequently traced to failures in PLC, DCS, and TSI systems, costing medium-siz...
-
How Does ABB System 800xA Enable Cost-Effective DCS Modernization?
This technical article examines a hybrid multi-brand DCS retrofit strategy centered on ABB System 800xA for petrochem...
-
Can a Multi-Vendor PM Checklist Cut PLC Downtime?
This article presents a standardized annual preventive maintenance checklist for mixed-vendor industrial control envi...
-
Why Emerson Hot Redundancy Retrofit Slashes Downtime by 96%?
Process plants relying on GE Fanuc single PLCs face 47% of unplanned outages from controller failure, costing $38,000...