Transform your home with the latest multi-electronics solutions, from intelligent lighting to vOptimize your operations with the Bently Nevada 3500 Monitoring System, offering real-time vibration and machinery condition monitoring to prevent failures and maximize uptime.oice-controlled devices all designed to make life easier, safer, and more connected.
SKU:IC670CHS103
GE Fanuc IC670CHS103 I/O Base Connector Style Hot Insertion
Manufacturer: General Electric
Product No.: IC670CHS103
Product Type: I/O Base
Product Origin: USA
Payment:T/T, Western Union
Weight: 600g
Shipping port: Xiamen
Warranty: 12 months
Share
- Fast Delivery
- 24/7 Support
- Quality Assurance
Description
GE Fanuc IC670CHS103 I/O Base
The GE Fanuc IC670CHS103 is a connector style I/O base. It supports hot insertion of modules. This base provides power and connectivity for Field Control I/O systems in industrial environments.
Technical Specifications
- Brand GE Fanuc
- Model IC670CHS103
- Product Weight 0.6 kg
- Type I/O Base, Connector Style, Hot Insertion
- Rated Voltage 115 VAC or 125 VDC
- Voltage Range 90–135 VAC / 105–150 VDC
- Frequency 47–63 Hz
- Power AC 48 VA max at 115V AC
- Power DC 24 Watts max at 125V DC
- Inrush Current 20 A peak (3 ms)
- DC Output 6.5 VDC
- Holdup Time 20 ms maximum
- Hazardous Location Class I, Division 2, Groups A/B/C/D
- Operating Temperature 0 to 60°C (32 to 140°F)
- Storage Temperature -40 to 85°C (-40 to 185°F)
- Humidity 5% to 95% non-condensing
- Shelf Life 1 year
Key Features
- Hot Insertion Install/remove modules without shutdown
- Dual Voltage Input Accepts 115V AC or 125V DC
- Stable Output Provides 6.5 VDC to modules
- Hazardous Area Rated Suitable for Class I Div 2
- Lightweight 0.6 kg for easy installation
- Wide Compatibility Works with IC670/CH/CHS modules
- Quick Recovery 20ms holdup time during power dips
Installation
- Mount the base on a DIN rail or panel
- Connect main power (115VAC or 125VDC)
- Insert I/O modules via connector interface
- Hot swap modules while system is powered
- Ensure environment is within 0 to 60°C
- Verify 6.5 VDC output to connected modules
Packaging
- One IC670CHS103 I/O Base
- Mounting hardware included
- Shipping weight: 0.9 kg
- Shipped via FedEx UPS DHL
FAQ
What is the weight of this I/O base?
The IC670CHS103 weighs 0.6 kg.
Does it support hot swapping?
Yes, it fully supports hot insertion of I/O modules.
What is the output voltage?
It provides a 6.5 Volts DC output to power connected modules.
Additional Specifications
- Black
Scalar (V/f)
Vector
AC-powered
Buying Guide
- Confirm the exact model, part number, and specifications before ordering.
- Ensure compatibility with your current machinery or control systems.
- Reach out via sale@etowonauto.com or +8617859788089 for technical assistance.
- Review delivery options, lead times, and shipping requirements.
- Follow manufacturer instructions and best practices during installation.
Shipping And Return
In-stock items are typically dispatched the same business day. For products not currently in stock, dispatch times may vary based on availability. International shipping is available, and shipping costs are calculated according to destination, weight, and carrier selection.
Returns are accepted within 30 days of receipt, provided items are unused and in original condition. Return shipping costs are the responsibility of the customer. Please contact us before returning any item to receive return authorization.
For more details, please review our Shipping & Return Policy.

3500/61-05-CN Temperature Monitor Module | Bently Nevada
3500/22-01-02-CN TDI Module Bently Nevada
Bently Nevada 3500/42-04-00 | Seismic Monitor
-
Fast Shipping
Original industrial automation parts available for prompt shipment worldwide.
-
Easy Returns
30-day return support with a 12-month warranty for reliable after-sales protection.
-
24/7 support
Responsive professional support to help maintain stable and efficient operations.
-
Genuine & Original
100% authentic, sourced directly from trusted industrial automation manufacturers.
Technical & Buying Guide
-
Can Emerson DeltaV DCS Cards Optimize Chemical Safety Loops?
This technical article examines how Emerson DeltaV DCS card upgrades address legacy control limitations in chemical p...
-
Is Partial CNC Board Replacement Better Than a Full System Upgrade?
This technical article examines the dominance of GE Fanuc CNC hardware in heavy-duty automation, supported by field d...
-
Can Genuine PLC Modules Cut DCS Downtime 60%?
This article examines how genuine Allen-Bradley PLC module replacement strategies directly reduce unplanned DCS downt...
-
Is Your GE Fanuc PLC Talking to ABB DCS?
This article reveals how cross-system data silos between GE Fanuc PLC and ABB DCS cause 8–15% production losses in pr...
-
Can Integrated PLC-DCS-TSI Fix Data Silos?
Most industrial digital twins remain static visualization tools because discrete control, process automation, and con...
-
How to Cut Power Plant Outages with ABB and GE Fanuc Retrofits?
This technical article outlines a data-driven approach to modernizing power plant control systems using a hybrid ABB ...