Transform your home with the latest multi-electronics solutions, from intelligent lighting to vOptimize your operations with the Bently Nevada 3500 Monitoring System, offering real-time vibration and machinery condition monitoring to prevent failures and maximize uptime.oice-controlled devices all designed to make life easier, safer, and more connected.
SKU:IC200PWR002
GE Fanuc IC200PWR002 DC Power Supply Module | VersaMax 24V
Manufacturer: General Electric
Product No.: IC200PWR002
Product Type: VersaMax Power Supply
Product Origin: USA
Payment:T/T, Western Union
Weight: 500g
Shipping port: Xiamen
Warranty: 12 months
Share
- Fast Delivery
- 24/7 Support
- Quality Assurance
Description
GE Fanuc IC200PWR002 VersaMax DC Power Supply Module
The GE Fanuc (now Emerson) IC200PWR002 is a 24V DC expanded power supply for the VersaMax platform. It provides primary or supplemental backplane power for CPUs, NIUs, and I/O modules.
Technical Specifications
- Brand & Model: GE Fanuc IC200PWR002
- Series: VersaMax DC Power Supply Module
- Input Voltage: 18 - 30 VDC (24 VDC nominal)
- Output Voltages: 5 VDC & 3.3 VDC
- Total Output Current: 1.5 Amps maximum
- 3.3V Output: 1.0 A maximum
- 5V Output: 1.5A maximum (shared total)
- Input Power: 11 Watts
- Holdup Time: 10 Milliseconds
- Extended Power: Yes
- Isolated Power: No
Protection & Electrical Ratings
- Protection Features: Short circuit, overload, and reverse polarity protection
- Inrush Current: 20A at 24V DC (6ms max); 25A at 30V DC (6ms max)
- Terminals: 5 screw terminals (+DC, -DC, Ground, 2x No Connection)
- Installation: Can be mounted directly or on a booster carrier
Physical Details & Application
- Dimensions: 49 mm H x 133.4 mm W x 39 mm D (1.93 x 5.25 x 1.54 in)
- Primary Use: Main power supply when installed on NIU or CPU
- Booster Use: Supplemental power supply when mounted on a booster carrier
- Compatibility: VersaMax CPU, NIU, and I/O modules
- Shipping: Available via FedEx, UPS, DHL
FAQ
-
Q: What is the IC200PWR002 module used for?
A: It supplies 5V/3.3V DC power to VersaMax system components, acting as either a main or booster supply. -
Q: What is the input voltage range?
A: It operates from 18 to 30 VDC, with 24 VDC as the standard nominal voltage. -
Q: Does it have built-in protection?
A: Yes, it includes protection against short circuits, overloads, and reverse polarity connections.
For pricing and technical support for the IC200PWR002, contact us at sale@etowonauto.com.
Additional Specifications
Scalar (V/f)
Vector
AC-powered
Buying Guide
- Confirm the exact model, part number, and specifications before ordering.
- Ensure compatibility with your current machinery or control systems.
- Reach out via sale@etowonauto.com or +8617859788089 for technical assistance.
- Review delivery options, lead times, and shipping requirements.
- Follow manufacturer instructions and best practices during installation.
Shipping And Return
In-stock items are typically dispatched the same business day. For products not currently in stock, dispatch times may vary based on availability. International shipping is available, and shipping costs are calculated according to destination, weight, and carrier selection.
Returns are accepted within 30 days of receipt, provided items are unused and in original condition. Return shipping costs are the responsibility of the customer. Please contact us before returning any item to receive return authorization.
For more details, please review our Shipping & Return Policy.

3500/61-05-CN Temperature Monitor Module | Bently Nevada
3500/22-01-02-CN TDI Module Bently Nevada
Bently Nevada 3500/42-04-00 | Seismic Monitor
-
Fast Shipping
Original industrial automation parts available for prompt shipment worldwide.
-
Easy Returns
30-day return support with a 12-month warranty for reliable after-sales protection.
-
24/7 support
Responsive professional support to help maintain stable and efficient operations.
-
Genuine & Original
100% authentic, sourced directly from trusted industrial automation manufacturers.
Technical & Buying Guide
-
Can a Multi-Vendor PM Checklist Cut PLC Downtime?
This article presents a standardized annual preventive maintenance checklist for mixed-vendor industrial control envi...
-
Why Emerson Hot Redundancy Retrofit Slashes Downtime by 96%?
Process plants relying on GE Fanuc single PLCs face 47% of unplanned outages from controller failure, costing $38,000...
-
Cut Migration Engineering Hours by 60% – How Does It Work?
This technical guide examines the operational risks and engineering overhead of maintaining separate GE Proficy HMI a...
-
Is Your 1756 Supply Chain Risking Production?
Counterfeit 1756 modules cause 68% of unplanned PLC downtime. This guide covers a four-step verification method, real...
-
Why Do 72% of Analog Loop Failures Trace Back to Wiring Errors?
This technical guide presents field-verified wiring protocols for integrating Emerson Rosemount 4–20mA HART transmitt...
-
GE Fanuc VersaMax: Did It Replace Obsolete ABB AC500-ECO?
This technical case study details a complete control system retrofit for a 1200m³/day municipal water plant. Our team...