Transform your home with the latest multi-electronics solutions, from intelligent lighting to vOptimize your operations with the Bently Nevada 3500 Monitoring System, offering real-time vibration and machinery condition monitoring to prevent failures and maximize uptime.oice-controlled devices all designed to make life easier, safer, and more connected.
SKU:FC-TSAO-0220M
FC-TSAO-0220M Honeywell FTA 2-Channel Output
Manufacturer: Honeywell
Product No.: FC-TSAO-0220M
Product Type: Termination Assembly
Product Origin: USA
Payment:T/T, Western Union
Weight: 1200g
Shipping port: Xiamen
Warranty: 12 months
Share
- Fast Delivery
- 24/7 Support
- Quality Assurance
Description
Product Overview
The FC-TSAO-0220M is a high-integrity Safe Analog Output Field Termination Assembly (FTA) module. It acts as a rugged interface between the system interconnection cable (SICC-0001/Lx) and external field wiring via secure screw terminals. Supporting two isolated 0(4)-20 mA analog output channels, this module controls field devices like valves and actuators in both safety-critical (up to SIL 3) and non-safety applications within process industries.
Core Technical Advantages
- High Isolation: Built-in isolation barriers safeguard upstream SAO-0220M modules from field-side electrical surges and transients up to IEC 1010 Overvoltage Category 3 standards.
- Robust Load Capacity: Supports a 40 V DC maximum voltage and a continuous 25 mA loop current per channel to drive high-impedance loads over long distances.
- Gas-Tight Connections: Heavy-duty screw terminals accept wires up to 2.5 mm² (AWG 14), preventing loose wiring caused by industrial machinery vibration.
Technical Specifications
| Parameter | FC-TSAO-0220M Specification | FC-TSAOH-0220M Specification |
|---|---|---|
| Channels | 2 Fully Isolated Channels | 2 Channels with Common 0V |
| Signal Range | 0-20 mA / 4-20 mA | 0-20 mA / 4-20 mA |
| Max Voltage | 40 V DC | 40 V DC |
| Max Current | 25 mA per channel | 25 mA per channel |
| Wire Size | 2.5 mm² (AWG 14) | 2.5 mm² (AWG 14) |
| Dimensions | 50 × 70 × 48 mm | 64 × 109 × 66 mm |
| Approvals | CE, TUV, UL, CSA, FM | CE, TUV, UL, CSA |
Installation & Maintenance
- Mounting: Snap onto standard TS32 or TS35 × 7.5 DIN rails. Allocate 51 mm of rail length for the TSAO module and 65 mm for the TSAOH variant.
- Wiring: Strip field wires to exactly 7 mm. Use a calibrated torque screwdriver to tighten terminal screws to 0.5 Nm (0.37 ft-lb).
- Shielding: Ground all field wiring shields at the cabinet entry panel to avoid noise interference in the 4-20 mA loop.
Why Choose This Module
- SIL 3 Compliance: Fully certified by TUV, UL, CSA, and FM for use in critical emergency shutdown (ESD) systems.
- Native Integration: Connects perfectly with Honeywell Safety Manager platforms using standard SICC-0001/Lx cables.
- Automatic Fault Diagnostics: Supports loop status monitoring to detect open-circuit and short-circuit field conditions instantly.
Technical FAQs
Q1: What separates the FC-TSAO-0220M from the FC-TSAOH-0220M?
A1: The standard TSAO version has fully isolated channels and a smaller footprint (50 mm width), while the TSAOH version shares a common 0V return and has a wider footprint (64 mm width).
Q2: Does this unit support line monitoring for field faults?
A2: Yes, when integrated with Honeywell safety controllers, it diagnoses open and short circuits across the control loop automatically.
Q3: Is this module safe for hazardous area installation?
A3: Yes. It carries FM and CSA approvals, allowing safe installation in Class I, Division 2 / Zone 2 environments when mounted inside an appropriate enclosure.
Additional Specifications
- Orange
- DC-powered
- Compact
- Modular
Scalar (V/f)
Vector
AC-powered
Buying Guide
- Confirm the exact model, part number, and specifications before ordering.
- Ensure compatibility with your current machinery or control systems.
- Reach out via sale@etowonauto.com or +8617859788089 for technical assistance.
- Review delivery options, lead times, and shipping requirements.
- Follow manufacturer instructions and best practices during installation.
Shipping And Return
In-stock items are typically dispatched the same business day. For products not currently in stock, dispatch times may vary based on availability. International shipping is available, and shipping costs are calculated according to destination, weight, and carrier selection.
Returns are accepted within 30 days of receipt, provided items are unused and in original condition. Return shipping costs are the responsibility of the customer. Please contact us before returning any item to receive return authorization.
For more details, please review our Shipping & Return Policy.

3500/61-05-CN Temperature Monitor Module | Bently Nevada
3500/22-01-02-CN TDI Module Bently Nevada
Bently Nevada 3500/42-04-00 | Seismic Monitor
-
Fast Shipping
Original industrial automation parts available for prompt shipment worldwide.
-
Easy Returns
30-day return support with a 12-month warranty for reliable after-sales protection.
-
24/7 support
Responsive professional support to help maintain stable and efficient operations.
-
Genuine & Original
100% authentic, sourced directly from trusted industrial automation manufacturers.
Technical & Buying Guide
-
How Does Full-Lifecycle Management Optimize PLC and DCS Assets?
Traditional industrial asset management relies on manual logging and reactive troubleshooting, causing 15–20% annual ...
-
Can an Integrated Spare Chain Slash Downtime?
Unplanned equipment failures cost Chinese factories ¥636,000 per hour. Traditional cross-border spare procurement tak...
-
Why Do 30% of Automation Upgrades Fail Due to Integration Gaps?
This technical article explains how digital-intelligent fusion overcomes fragmented workshop operations using industr...
-
Why Do Heavy Industries Trust GE Fanuc PLC and DCS Systems?
This article examines how GE Fanuc core components solve reliability gaps in heavy-load factory automation. It covers...
-
How Does Bently Nevada Predict Failures 180 Days in Advance?
Standard PLC and DCS systems often miss early vibration anomalies in rotating machinery, leading to 68% of sudden mec...
-
How Does ABB Omni-Measurement Eliminate Process Safety Blind Spots?
ABB Omni-Measurement closes process safety blind spots using predictive analytics and cross-validated sensing. Real r...