Transform your home with the latest multi-electronics solutions, from intelligent lighting to vOptimize your operations with the Bently Nevada 3500 Monitoring System, offering real-time vibration and machinery condition monitoring to prevent failures and maximize uptime.oice-controlled devices all designed to make life easier, safer, and more connected.
SKU:VFD007EL21W-1
Delta VFD EL-W 0.25 Horsepower 230V Motor Drive VFD007EL21W
Manufacturer: Delta
Product No.: VFD007EL21W-1
Product Type: AC Drive
Product Origin: CN
Payment:T/T, Western Union
Weight: 1000g
Shipping port: Xiamen
Warranty: 12 months
Share
- Fast Delivery
- 24/7 Support
- Quality Assurance
Description
Product Overview
The VFD007EL21W(-1) is an ultra-compact, cost-effective micro-type AC motor drive from Delta’s streamlined VFD EL-W Series. Engineered specifically to optimize space and reduce costs in low-horsepower applications, this 0.25 HP (0.2 kW) variable frequency inverter provides stable velocity modulation for standard automation equipment like small commercial mixers, fans, pumps, and light-duty material conveyors. It operates efficiently on a standard 1-phase 230 V AC input line and delivers a steady 1.6 A output. Featuring a highly specialized shallow-depth housing and an incredibly lightweight structure weighing only 2.2 lbs (1.0 kg), it delivers exceptional power density for restricted panel layouts.
Core Technical Advantages
Optimized Shallow-Depth Housing
The specialized EL-W series features a modified physical geometry with a reduced depth profile. With a total compact installation space envelope of just 3.62 × 3.23 × 6.38 inches, this layout lets system builders mount the drive inside shallow electrical enclosures where standard industrial inverters cannot physically fit.
High-Density Side-by-Side Mounting
The optimized thermal dissipation architecture allows high-density side-by-side configurations on standard DIN rails. This structural arrangement cuts cabinet space requirements dramatically while providing highly reliable power output from a single-phase supply line.
Efficient Scalar Performance
Supporting a maximum adjustable output frequency up to 400 Hz, the open-loop V/Hz (Scalar) control system ensures accurate torque compensation and smooth speed curves for standard induction motors and small-scale processing machinery.
Technical Specifications
| Parameter | Specification Details |
|---|---|
| Manufacturer | Delta Products (VFD EL-W Series) |
| Model Number | VFD007EL21W(-1) |
| Motor Power Rating | 0.25 HP / 0.2 kW |
| Rated Output Amps | 1.6 Amps |
| Nominal Input VAC | 230 Volts AC (Range: 200–240 V) |
| Input Phase | 1-Phase |
| Device Net Weight | 2.2 lbs (1.0 kg) |
| Enclosure Rating | IP20 |
| Dimensions (W × H × D) | 3.62 × 3.23 × 6.38 Inches |
Installation and Maintenance
Enclosure Thermal Layouts
The IP20 open-type chassis must sit within a clean, dry, well-ventilated cabinet environment free from oil mist, moisture, and conductive metal shavings. Keep a minimum vertical clearance of 50 mm above and below the module to allow heat from the cooling vents to escape properly.
Power Integration Rules
Terminate incoming single-phase mains wires exclusively to input terminals L1 and L2. Wire the motor leads directly to terminals U, V, and W. Never introduce utility AC lines to the U, V, W outputs, or the internal power semiconductor components will suffer irreversible catastrophic failure.
Braking Configuration
For operations involving rapid deceleration steps, fine-tune the internal deceleration parameters ($DEC$) to prevent regenerative energy from creating an overvoltage spike. Ensure proper line filtering is applied to maintain compliance with local industrial EMC guidelines.
Engineering Advantages
Onboard User Controls
The built-in human-machine interface includes a clear digital parameter screen and localized control buttons. This allows plant electricians to modify speed curves, monitor running amperage, and pull historical fault logs directly on the shop floor without secondary service computers.
Streamlined V/Hz Regulation
By optimizing high-demand open-loop scalar algorithms, this drive offers automatic torque boosting, multi-step operations, and integrated electronic thermal protection without the high cost overhead of advanced vector-drive systems.
Active Circuit Defense
Onboard firmware elements actively check for overcurrent, overvoltage, low input voltage, and ground leaks. If a fault is found, the inverter trips instantly to protect both the internal electronic components and the motor winding insulation.
Technical FAQs
Q1: What is the main design difference between the standard VFD-EL series and this EL-W variant?
A1: The EL-W variant features a modified structural layout that optimizes installation dimensions for shallower enclosures. It focuses on core open-loop application requirements, offering a lighter weight of 2.2 lbs and a lower cost framework for highly competitive automation tasks.
Q2: Can this single-phase drive be run on a 3-phase AC input supply?
A2: No. This unit is strictly rated for 1-phase 230 V AC input line connections. Attempting to run it on 3-phase lines can lead to erratic voltage monitoring behavior or unbalanced thermal stress on the input bridge rectifier circuits.
Q3: How do I avoid acceleration stall faults when running heavy conveyor loads?
A3: If the drive trips on overcurrent or struggles at startup, increase the acceleration time parameter ($ACC$) to give the drive more time to ramp up, or fine-tune the manual torque boost configuration to supply more voltage at low speeds.
Additional Specifications
- Black
- Gray
Scalar (V/f)
Vector
AC-powered
Buying Guide
- Confirm the exact model, part number, and specifications before ordering.
- Ensure compatibility with your current machinery or control systems.
- Reach out via sale@etowonauto.com or +8617859788089 for technical assistance.
- Review delivery options, lead times, and shipping requirements.
- Follow manufacturer instructions and best practices during installation.
Shipping And Return
In-stock items are typically dispatched the same business day. For products not currently in stock, dispatch times may vary based on availability. International shipping is available, and shipping costs are calculated according to destination, weight, and carrier selection.
Returns are accepted within 30 days of receipt, provided items are unused and in original condition. Return shipping costs are the responsibility of the customer. Please contact us before returning any item to receive return authorization.
For more details, please review our Shipping & Return Policy.

3500/61-05-CN Temperature Monitor Module | Bently Nevada
3500/22-01-02-CN TDI Module Bently Nevada
Bently Nevada 3500/42-04-00 | Seismic Monitor
-
Fast Shipping
Original industrial automation parts available for prompt shipment worldwide.
-
Easy Returns
30-day return support with a 12-month warranty for reliable after-sales protection.
-
24/7 support
Responsive professional support to help maintain stable and efficient operations.
-
Genuine & Original
100% authentic, sourced directly from trusted industrial automation manufacturers.
Technical & Buying Guide
-
How does hierarchical control raise factory OEE from 64% to 82%?
This article explains how hierarchical cloud-edge collaborative control replaces fragmented industrial architectures....
-
Can DCS Intelligent Regulation Fix Thermal Power Energy Imbalance?
This article explains how intelligent DCS regulation with MPC and cloud-based control solves energy-production imbala...
-
Can Continuous Automation Iteration Cut Factory Costs by 18-25%?
Static industrial control systems create hidden annual cost increases of 18-25%. Phased PLC and DCS program iteration...
-
Can Anti-Interference Hardware End 38% of Automation Downtime?
Field data from chemical, wind, and automotive plants proves that industrial hardware with full IEC 61000-4 EMC certi...
-
How Does Full-Lifecycle Management Optimize PLC and DCS Assets?
Traditional industrial asset management relies on manual logging and reactive troubleshooting, causing 15–20% annual ...
-
Can an Integrated Spare Chain Slash Downtime?
Unplanned equipment failures cost Chinese factories ¥636,000 per hour. Traditional cross-border spare procurement tak...
