Transform your home with the latest multi-electronics solutions, from intelligent lighting to vOptimize your operations with the Bently Nevada 3500 Monitoring System, offering real-time vibration and machinery condition monitoring to prevent failures and maximize uptime.oice-controlled devices all designed to make life easier, safer, and more connected.
SKU:CI858
CI858 ABB Communication Interface DriveBus Protocol
Manufacturer: ABB
Product No.: CI858
Product Type: Interface Module
Product Origin: SE
Payment:T/T, Western Union
Weight: 700g
Shipping port: Xiamen
Warranty: 12 months
Share
- Fast Delivery
- 24/7 Support
- Quality Assurance
Description
CI858 ABB DriveBus Communication Interface
The CI858 (3BSE018135R1) is a DriveBus communication interface from ABB. It connects ABB Drives and ABB Special I/O units to the AC 800M controller via the CEX-Bus. No external power source is required. The DriveBus protocol is specifically designed for sectional drive applications in ABB rolling mill drive systems and paper machine control systems.
Technical Specifications
| Article Number | 3BSE018135R1 |
| Communication Protocol | ABB DriveBus |
| Transmission Speed | 8 Mbit/s |
| Connector Type | Optical |
| Hot Swap | Yes |
| Line Redundancy | No |
| Module Redundancy | No |
| Max Units on CEX Bus | 2 |
| 24V Current Consumption | 200 mA typical |
| Operating Temperature | +5 to +55 °C (+41 to +131 °F) |
| Storage Temperature | -40 to +70 °C (-40 to +158 °F) |
| Protection Class | IP20 |
| Corrosion Protection | G3 compliant to ISA 71.04 |
| Marine Certificates | ABS, BV, DNV-GL, LR |
| CE Marking | Yes |
| RoHS Compliance | DIRECTIVE 2011-65-EU |
| WEEE Compliance | DIRECTIVE 2012-19-EU |
Dimensions
| Width | 59 mm (2.3 in) |
| Height | 185 mm (7.3 in) |
| Depth | 127.5 mm (5.0 in) |
| Weight | 700 g (1.5 lbs) |
Installation & Application
Mount the CI858 on the CEX-Bus inside the AC 800M controller cabinet. The processor unit powers the CI858 directly through the bus connection. Connect up to 24 ABB drives to a single CI858. For multiple drives, use the NDBU branching unit to build a logical bus with physical star topology. Chain multiple branching units as needed. A maximum of two CI858 units can connect to one AC 800M controller.
FAQs
Q1: Does CI858 require external power?
A1: No. The CI858 draws power from the processor unit via the CEX-Bus. Typical consumption is 200 mA at 24V.
Q2: How many drives can one CI858 support?
A2: A single CI858 supports up to 24 ABB drives. An NDBU branching unit is required when connecting more than one drive.
Q3: What industries use the CI858?
A3: Sectional drive applications including ABB rolling mill drive systems and ABB paper machine control systems.
Q4: Is the CI858 suitable for marine environments?
A4: Yes. It holds marine certificates from ABS, BV, DNV-GL, and LR.
Additional Specifications
- White
- DC-powered
- Modular
Scalar (V/f)
Vector
AC-powered
Buying Guide
- Confirm the exact model, part number, and specifications before ordering.
- Ensure compatibility with your current machinery or control systems.
- Reach out via sale@etowonauto.com or +8617859788089 for technical assistance.
- Review delivery options, lead times, and shipping requirements.
- Follow manufacturer instructions and best practices during installation.
Shipping And Return
In-stock items are typically dispatched the same business day. For products not currently in stock, dispatch times may vary based on availability. International shipping is available, and shipping costs are calculated according to destination, weight, and carrier selection.
Returns are accepted within 30 days of receipt, provided items are unused and in original condition. Return shipping costs are the responsibility of the customer. Please contact us before returning any item to receive return authorization.
For more details, please review our Shipping & Return Policy.

3500/61-05-CN Temperature Monitor Module | Bently Nevada
3500/22-01-02-CN TDI Module Bently Nevada
Bently Nevada 3500/42-04-00 | Seismic Monitor
-
Fast Shipping
Original industrial automation parts available for prompt shipment worldwide.
-
Easy Returns
30-day return support with a 12-month warranty for reliable after-sales protection.
-
24/7 support
Responsive professional support to help maintain stable and efficient operations.
-
Genuine & Original
100% authentic, sourced directly from trusted industrial automation manufacturers.
Technical & Buying Guide
-
How Do You Fix ControlLogix Redundancy Switchover Failures?
This article examines the hidden causes of Allen-Bradley 1756 redundant CPU switchover failures on oil and gas ski...
-
Why Is INFI90 End-of-Life a Growing Risk for Power DCS?
This article examines ABB Bailey INFI90 end-of-life risks in power DCS environments and presents a three-tier moderni...
-
How Do MTL Intrinsic Safety Barriers Protect Petrochemical DCS Loops?
This article explains how industrial automation teams size MTL intrinsic safety barriers for petrochemical DCS a...
-
How Does Bently 3500 TSI Detect Proximity Probe Faults?
This article explains Bently 3500 TSI proximity probe troubleshooting, technical parameters and calibrated insta...
-
How to Diagnose Yokogawa CENTUM VP FCS Redundancy Faults?
This article explains how industrial automation teams can diagnose and debug Yokogawa CENTUM VP FCS controller redund...
-
How Does Siemens S7-1500 PLC Handle PROFINET Real-Time Jitter?
This article examines measurable PROFINET fault modes on Siemens S7-1500 PLC controllers and provides field-prov...