Transform your home with the latest multi-electronics solutions, from intelligent lighting to vOptimize your operations with the Bently Nevada 3500 Monitoring System, offering real-time vibration and machinery condition monitoring to prevent failures and maximize uptime.oice-controlled devices all designed to make life easier, safer, and more connected.
SKU:CC-PAIX02
CC-PAIX02 Honeywell | High Level Analog Input Module
Manufacturer: Honeywell
Product No.: CC-PAIX02
Product Type: Analog Input Module
Product Origin: USA
Payment:T/T, Western Union
Weight: 350g
Shipping port: Xiamen
Warranty: 12 months
Share
- Fast Delivery
- 24/7 Support
- Quality Assurance
Description
Honeywell CC-PAIX02 High Level Analog Input Module
The CC-PAIX02 from Honeywell delivers high-performance analog signal acquisition for process control systems. This high level analog input module provides precise measurement capabilities for various industrial signals. With immediate availability and reliable performance, it serves as a key component in Honeywell's control system architecture.
Technical Specifications
- Manufacturer: Honeywell
- Model: CC-PAIX02
- Part Number: CC-PAIX02
- Module Type: High Level Analog Input
- Number of Channels: 16 single-ended or 8 differential
- Input Signals: 4-20mA, 0-20mA, 0-5V, 0-10V, ±5V, ±10V
- Resolution: 16-bit
- Update Rate: 50 ms per channel
- Accuracy: ±0.1% of full scale at 25°C
- Input Impedance: 1MΩ voltage, 250Ω current
- Common Mode Rejection: >100 dB at 50/60 Hz
- Normal Mode Rejection: >60 dB at 50/60 Hz
- Isolation: 500V channel to bus
- Operating Temperature: 0°C to 60°C
- Power Consumption: 5VDC @ 900mA, 24VDC @ 120mA
- Connection: Removable screw terminal block
- LED Indicators: Power, status, channel activity
- Weight: 0.35 kg
- Availability: In Stock
- Lead Time: 2-3 Working Days
Signal Integrity
- High 1MΩ input impedance minimizes voltage signal loading
- 250Ω precision resistor for accurate current loop measurement
- >100dB common mode rejection eliminates ground loop interference
- >60dB normal mode rejection filters line frequency noise
- 500V isolation protects system from field-side transients
Frequently Asked Questions
- What signals does this module accept? 4-20mA, 0-10V, ±10V and other standard industrial signals.
- How many channels are available? 16 single-ended or 8 differential input channels.
- What is the typical delivery time? Usually ships within 7-10 working days.
Additional Specifications
Scalar (V/f)
Vector
AC-powered
Buying Guide
- Confirm the exact model, part number, and specifications before ordering.
- Ensure compatibility with your current machinery or control systems.
- Reach out via sale@etowonauto.com or +8617859788089 for technical assistance.
- Review delivery options, lead times, and shipping requirements.
- Follow manufacturer instructions and best practices during installation.
Shipping And Return
In-stock items are typically dispatched the same business day. For products not currently in stock, dispatch times may vary based on availability. International shipping is available, and shipping costs are calculated according to destination, weight, and carrier selection.
Returns are accepted within 30 days of receipt, provided items are unused and in original condition. Return shipping costs are the responsibility of the customer. Please contact us before returning any item to receive return authorization.
For more details, please review our Shipping & Return Policy.

3500/61-05-CN Temperature Monitor Module | Bently Nevada
3500/22-01-02-CN TDI Module Bently Nevada
Bently Nevada 3500/42-04-00 | Seismic Monitor
-
Fast Shipping
Original industrial automation parts available for prompt shipment worldwide.
-
Easy Returns
30-day return support with a 12-month warranty for reliable after-sales protection.
-
24/7 support
Responsive professional support to help maintain stable and efficient operations.
-
Genuine & Original
100% authentic, sourced directly from trusted industrial automation manufacturers.
Technical & Buying Guide
-
Can a Multi-Vendor PM Checklist Cut PLC Downtime?
This article presents a standardized annual preventive maintenance checklist for mixed-vendor industrial control envi...
-
Why Emerson Hot Redundancy Retrofit Slashes Downtime by 96%?
Process plants relying on GE Fanuc single PLCs face 47% of unplanned outages from controller failure, costing $38,000...
-
Cut Migration Engineering Hours by 60% – How Does It Work?
This technical guide examines the operational risks and engineering overhead of maintaining separate GE Proficy HMI a...
-
Is Your 1756 Supply Chain Risking Production?
Counterfeit 1756 modules cause 68% of unplanned PLC downtime. This guide covers a four-step verification method, real...
-
Why Do 72% of Analog Loop Failures Trace Back to Wiring Errors?
This technical guide presents field-verified wiring protocols for integrating Emerson Rosemount 4–20mA HART transmitt...
-
GE Fanuc VersaMax: Did It Replace Obsolete ABB AC500-ECO?
This technical case study details a complete control system retrofit for a 1200m³/day municipal water plant. Our team...