Transform your home with the latest multi-electronics solutions, from intelligent lighting to vOptimize your operations with the Bently Nevada 3500 Monitoring System, offering real-time vibration and machinery condition monitoring to prevent failures and maximize uptime.oice-controlled devices all designed to make life easier, safer, and more connected.
SKU:1783-US8T
Allen-Bradley 1783-US8T Stratix 2000 Unmanaged Switch
Manufacturer: Allen-Bradley
Product No.: 1783-US8T
Product Type: Ethernet Switch
Product Origin: USA
Payment:T/T, Western Union
Weight: 380g
Shipping port: Xiamen
Warranty: 12 months
Share
- Fast Delivery
- 24/7 Support
- Quality Assurance
Description
Product Overview
The Allen-Bradley 1783-US8T is a reliable Stratix 2000™ unmanaged Ethernet switch designed for simple, plug-and-play connectivity in industrial automation environments. Featuring eight (8) RJ45 Fast Ethernet ports, this switch provides an easy way to expand your network without the need for complex configuration. Its compact, open-style design is optimized for DIN rail mounting within control panels, offering a cost-effective solution for connecting controllers, HMIs, and other Ethernet-enabled field devices.
Technical Configuration
- Manufacturer: Rockwell Automation / Allen-Bradley
- Model Series: Stratix 2000
- Catalog Number: 1783-US8T
- Port Count: 8 RJ45 Copper Ports (10/100 Mbps)
- Power Input: 24V Nominal (Supports 12-48V DC or 18-30V AC)
- Switch Type: Unmanaged (Plug-and-Play)
- Mounting: DIN Rail Mount (Open-style rating)
Technical Specifications
| Net Weight | 0.38 kg (0.84 lbs) | Operating Temp | 0 to 60°C (32 to 140°F) |
| Dimensions (HxWxD) | 114.5 x 45.6 x 76.8 mm | Inrush Current | 1.31 A (Maximum) |
| Power Consumption | 4.6 W; Wiring Category 1 (Power) & Category 2 (Communication) | ||
Installation & Powering Features
1. Versatile Power Options: The 1783-US8T is highly flexible regarding power sources. It accepts a wide range of DC voltages (12-48V) and can also be powered by 24V AC, making it compatible with various machine power distribution standards. To ensure safety, the power input must be supplied by a SELV (Safety Extra Low Voltage) source.
2. Grounding Requirements: For reliable operation and noise immunity, the switch requires a functional earth connection. It is recommended to use 2.5 mm² (14 AWG) copper wire with a suitable ring terminal for the grounding lug, ensuring the wire is rated for at least 30°C above the surrounding ambient temperature.
3. Space-Saving Design: With a narrow width of approximately 45.6 mm, the 1783-US8T is designed to fit into crowded control cabinets. The "open-style" rating means the switch should be installed in an appropriate industrial enclosure (such as a NEMA or IP rated cabinet) to protect the internal components from environmental contaminants.
Engineering Advantages
The Stratix 2000 series removes the technical barrier to industrial networking. The 1783-US8T automatically negotiates speed and duplex settings for each connected device, eliminating the need for IT intervention or software management. With a maximum power consumption of only 4.6W and robust vibration/shock resistance, this switch is engineered for long-term stability in factory floor environments where reliability is paramount for non-stop production cycles.
Technical FAQs
Q1: Does this switch support Gigabit speeds?
A1: No, the 1783-US8T features Fast Ethernet ports with speeds up to 100 Mbps, which is sufficient for the majority of industrial I/O and PLC communication tasks.
Q2: Can I use fiber optic connections with this model?
A2: This specific model (1783-US8T) features 8 RJ45 copper ports only. For fiber optic capability, you would need a Stratix 2000 model that includes SFP ports.
Q3: Is any configuration software required for startup?
A3: No. As an unmanaged switch, the 1783-US8T works immediately upon power-up and connection to the network.
Additional Specifications
Scalar (V/f)
Vector
AC-powered
Buying Guide
- Confirm the exact model, part number, and specifications before ordering.
- Ensure compatibility with your current machinery or control systems.
- Reach out via sale@etowonauto.com or +8617859788089 for technical assistance.
- Review delivery options, lead times, and shipping requirements.
- Follow manufacturer instructions and best practices during installation.
Shipping And Return
In-stock items are typically dispatched the same business day. For products not currently in stock, dispatch times may vary based on availability. International shipping is available, and shipping costs are calculated according to destination, weight, and carrier selection.
Returns are accepted within 30 days of receipt, provided items are unused and in original condition. Return shipping costs are the responsibility of the customer. Please contact us before returning any item to receive return authorization.
For more details, please review our Shipping & Return Policy.

3500/61-05-CN Temperature Monitor Module | Bently Nevada
3500/22-01-02-CN TDI Module Bently Nevada
Bently Nevada 3500/42-04-00 | Seismic Monitor
-
Fast Shipping
Original industrial automation parts available for prompt shipment worldwide.
-
Easy Returns
30-day return support with a 12-month warranty for reliable after-sales protection.
-
24/7 support
Responsive professional support to help maintain stable and efficient operations.
-
Genuine & Original
100% authentic, sourced directly from trusted industrial automation manufacturers.
Technical & Buying Guide
-
How does hierarchical control raise factory OEE from 64% to 82%?
This article explains how hierarchical cloud-edge collaborative control replaces fragmented industrial architectures....
-
Can DCS Intelligent Regulation Fix Thermal Power Energy Imbalance?
This article explains how intelligent DCS regulation with MPC and cloud-based control solves energy-production imbala...
-
Can Continuous Automation Iteration Cut Factory Costs by 18-25%?
Static industrial control systems create hidden annual cost increases of 18-25%. Phased PLC and DCS program iteration...
-
Can Anti-Interference Hardware End 38% of Automation Downtime?
Field data from chemical, wind, and automotive plants proves that industrial hardware with full IEC 61000-4 EMC certi...
-
How Does Full-Lifecycle Management Optimize PLC and DCS Assets?
Traditional industrial asset management relies on manual logging and reactive troubleshooting, causing 15–20% annual ...
-
Can an Integrated Spare Chain Slash Downtime?
Unplanned equipment failures cost Chinese factories ¥636,000 per hour. Traditional cross-border spare procurement tak...
