Transform your home with the latest multi-electronics solutions, from intelligent lighting to vOptimize your operations with the Bently Nevada 3500 Monitoring System, offering real-time vibration and machinery condition monitoring to prevent failures and maximize uptime.oice-controlled devices all designed to make life easier, safer, and more connected.
SKU:1756-PB72K
Allen-Bradley 1756-PB72K ControlLogix DC Power Supply
Manufacturer: Allen-Bradley
Product No.: 1756-PB72K
Product Type: Power Supply Module
Product Origin: USA
Payment:T/T, Western Union
Weight: 770g
Shipping port: Xiamen
Warranty: 12 months
Share
- Fast Delivery
- 24/7 Support
- Quality Assurance
Description
Allen-Bradley 1756-PB72K ControlLogix DC Power Supply Module
The Allen-Bradley 1756-PB72K is a 75-watt DC power supply module designed specifically for ControlLogix chassis. It converts a 24V DC input into multiple voltage rails required by system modules.
Technical Specifications
- Brand & Model: Allen-Bradley 1756-PB72K
- Input Voltage: 18 - 32 Volts DC (24V DC nominal)
- Output Voltages: 1.2V DC, 3.3V DC, 5.1V DC, 24V DC
- Rated Output Power: 75 Watts at 60°C
- Hold-up Time: 40 milliseconds at 24V input
- Inrush Current: 30 Amps (peak)
- Operating Temperature: 0 to 60°C
- Weight: 0.77 kg (1.7 lbs)
Features & Benefits
- Multi-Voltage Output: Supplies all necessary voltages (1.2V, 3.3V, 5.1V, 24V) for ControlLogix processors, communication, and I/O modules from a single 24V DC source.
- Wide Input Range: Tolerates input voltage fluctuations from 18V to 32V DC, ensuring stable operation in typical industrial DC systems.
- Compact & Efficient: High power density (75W) in a lightweight module saves valuable control panel space.
- Robust Design: Built for reliable performance in standard industrial environments (0-60°C).
FAQ
-
Q: What is the 1756-PB72K power supply used for?
A: It is the primary power source for a ControlLogix rack, converting a plant 24V DC supply to the specific voltages needed by the controller, network, and I/O modules. -
Q: Why are multiple output voltages needed?
A: Different modules within the ControlLogix system require different core voltages (e.g., 1.2V/3.3V for processors, 5V/24V for I/O and communications). -
Q: Can it be used in a redundant setup?
A: Yes, multiple 1756-PB72K modules can be configured in a redundant power supply system to increase availability for critical applications.
Technical Documentation
Download Detailed Specifications (PDF)
For pricing and technical support for the 1756-PB72K, contact us at sale@etowonauto.com.
Additional Specifications
Scalar (V/f)
Vector
AC-powered
Buying Guide
- Confirm the exact model, part number, and specifications before ordering.
- Ensure compatibility with your current machinery or control systems.
- Reach out via sale@etowonauto.com or +8617859788089 for technical assistance.
- Review delivery options, lead times, and shipping requirements.
- Follow manufacturer instructions and best practices during installation.
Shipping And Return
In-stock items are typically dispatched the same business day. For products not currently in stock, dispatch times may vary based on availability. International shipping is available, and shipping costs are calculated according to destination, weight, and carrier selection.
Returns are accepted within 30 days of receipt, provided items are unused and in original condition. Return shipping costs are the responsibility of the customer. Please contact us before returning any item to receive return authorization.
For more details, please review our Shipping & Return Policy.

3500/61-05-CN Temperature Monitor Module | Bently Nevada
3500/22-01-02-CN TDI Module Bently Nevada
Bently Nevada 3500/42-04-00 | Seismic Monitor
-
Fast Shipping
Original industrial automation parts available for prompt shipment worldwide.
-
Easy Returns
30-day return support with a 12-month warranty for reliable after-sales protection.
-
24/7 support
Responsive professional support to help maintain stable and efficient operations.
-
Genuine & Original
100% authentic, sourced directly from trusted industrial automation manufacturers.
Technical & Buying Guide
-
Can Full-Cycle Data Recording Solve Hidden PLC and DCS Faults?
This article examines how GE full-cycle data recording addresses the critical blind spots in traditional PLC and DCS ...
-
How Can Smart Sensor Maintenance Cut False Alarms by 71%?
This article presents a data-driven approach to gas sensor lifecycle management for hazardous area monitoring instrum...
-
Can Standardized Engineering Cut Factory Upgrade Costs by 40%?
This article presents a data‑driven alternative to full control system replacements in brown‑field plants. Allen‑Brad...
-
Choosing the Right Gas Detector for Chemical Safety?
This article examines the operational and financial impact of unreliable gas-sensing hardware in chemical process pla...
-
Is Mixed-Plant Data Fragmentation Costing You More?
Hybrid manufacturing facilities often lose nearly one-third of production data across disjointed PLC and DCS systems,...
-
Can Transient Monitoring Prevent Rotating Machinery Failures?
This technical article examines the critical role of transient data capture in rotating machinery protection, highlig...