Transform your home with the latest multi-electronics solutions, from intelligent lighting to vOptimize your operations with the Bently Nevada 3500 Monitoring System, offering real-time vibration and machinery condition monitoring to prevent failures and maximize uptime.oice-controlled devices all designed to make life easier, safer, and more connected.
SKU:1756-L83ES
Allen-Bradley 1756-L83ES GuardLogix5580 Safety Controller 10MB
Manufacturer: Allen-Bradley
Product No.: 1756-L83ES
Product Type: Safety Controller
Product Origin: USA
Payment:T/T, Western Union
Weight: 390g
Shipping port: Xiamen
Warranty: 12 months
Share
- Fast Delivery
- 24/7 Support
- Quality Assurance
Description
Allen-Bradley 1756-L83ES GuardLogix5580 Safety Controller
Allen-Bradley 1756-L83ES is a GuardLogix5580 safety controller for ControlLogix systems. Features 10MB standard memory and 5MB safety memory. Includes USB 2.0 port and 1GB Ethernet port supporting up to 250 EtherNet/IP nodes. Weight: 0.39 kg (0.86 lbs).
Technical Specifications
| Parameter | Specification |
| Manufacturer | Allen-Bradley / Rockwell Automation |
| Model | 1756-L83ES |
| Series | ControlLogix / GuardLogix5580 |
| User Memory | 10 MB |
| Safety Memory | 5 MB |
| Supported EtherNet/IP Nodes | 250 maximum |
| Controller Tasks | 31 standard / 1 safety |
| Programs per Task | 1000 |
| Digital I/O Maximum | 128,000 |
| Analog I/O Maximum | 4,000 |
| Built-in Communication | USB 2.0, 1GB Ethernet |
| Current Draw at 1.2V DC | 5.0 mA |
| Current Draw at 5.1V DC | 1.2 A |
| Power Dissipation | 21.2 BTU/hr |
| Operating Temperature | 0°C to +60°C (32°F to 140°F) |
| Storage Temperature | -40°C to +85°C (-40°F to 185°F) |
| Weight | 0.39 kg (0.86 lbs) |
Key Features
- GuardLogix5580 safety controller with 10MB user memory and 5MB safety memory
- Supports 250 EtherNet/IP nodes with embedded 1GB Ethernet port
- USB 2.0 port for programming and firmware updates
- 31 standard tasks and 1 safety task for flexible control
- 1000 programs per task for large-scale applications
- CE, RCM, KC, CSA, and c-UL-us certified
- 4-character alpha/numeric display for status monitoring
Installation Guidelines (Field Engineer Notes)
Slot Installation: Install controller into any slot in ControlLogix chassis. Power off chassis before insertion. Secure with locking latch.
Network Connection: Use Cat5e or better for Ethernet connections. For safety communication, use isolated network segments or managed switches with IGMP snooping.
USB Connection: Use USB 2.0 certified cable. Direct connection to PC only. Do not use extension cables longer than 3 meters.
Firmware Updates: Use ControlFLASH software via Ethernet or USB. Verify compatibility of all modules after firmware update.
FAQs
Q1. What is the difference between standard and safety memory?
A1. Standard memory (10MB) stores standard control programs. Safety memory (5MB) stores safety-validated logic isolated from standard tasks.
Q2. Can this controller be used with older ControlLogix modules?
A2. Yes. The 1756-L83ES is compatible with all ControlLogix 1756 series modules. Verify firmware compatibility with older modules.
Q3. What is the maximum number of EtherNet/IP nodes supported?
A3. The controller supports up to 250 EtherNet/IP nodes. For larger networks, consider adding additional communication modules.
Additional Specifications
Scalar (V/f)
Vector
AC-powered
Buying Guide
- Confirm the exact model, part number, and specifications before ordering.
- Ensure compatibility with your current machinery or control systems.
- Reach out via sale@etowonauto.com or +8617859788089 for technical assistance.
- Review delivery options, lead times, and shipping requirements.
- Follow manufacturer instructions and best practices during installation.
Shipping And Return
In-stock items are typically dispatched the same business day. For products not currently in stock, dispatch times may vary based on availability. International shipping is available, and shipping costs are calculated according to destination, weight, and carrier selection.
Returns are accepted within 30 days of receipt, provided items are unused and in original condition. Return shipping costs are the responsibility of the customer. Please contact us before returning any item to receive return authorization.
For more details, please review our Shipping & Return Policy.

3500/61-05-CN Temperature Monitor Module | Bently Nevada
3500/22-01-02-CN TDI Module Bently Nevada
Bently Nevada 3500/42-04-00 | Seismic Monitor
-
Fast Shipping
Original industrial automation parts available for prompt shipment worldwide.
-
Easy Returns
30-day return support with a 12-month warranty for reliable after-sales protection.
-
24/7 support
Responsive professional support to help maintain stable and efficient operations.
-
Genuine & Original
100% authentic, sourced directly from trusted industrial automation manufacturers.
Technical & Buying Guide
-
Why Do 42% of Offshore DCS Downtime Events Trace to Power Modules?
This technical analysis examines the root causes of Allen‑Bradley power module failures in offshore control cabi...
-
Can Layered PLC Fix Chemical Batch Failures?
This technical article presents field-validated ABB AC800M configuration strategies for high-stability fine chemical ...
-
How to Select GE Fanuc 90-30 Spare Parts for Hot Rolling Mills?
This article provides a technical guide for selecting and managing GE Fanuc Series 90-30 PLC spare parts in meta...
-
How Does Bently Nevada 3500 Reduce Unplanned Turbine Trips?
This technical article analyzes the quantitative value of the Bently Nevada 3500 TSI system in thermal power shaft pr...
-
Dual Compliance Standards for Pharma Automation?
This article presents a quantified engineering methodology for explosion-proof PLC and DCS system design in GMP-certi...
-
How to Avoid Bulk Sourcing Risks for Power Plant Control Spares?
This guide presents field-validated strategies for bulk sourcing industrial control spares in power plants. It q...