Transform your home with the latest multi-electronics solutions, from intelligent lighting to vOptimize your operations with the Bently Nevada 3500 Monitoring System, offering real-time vibration and machinery condition monitoring to prevent failures and maximize uptime.oice-controlled devices all designed to make life easier, safer, and more connected.
SKU:1747-L542
Allen-Bradley 1747-L542 SLC 5/04 32KB Modular CPU Processor Unit
Manufacturer: Allen-Bradley
Product No.: 1747-L542
Product Type: CPU Processor Module
Product Origin: USA
Payment:T/T, Western Union
Weight: 450g
Shipping port: Xiamen
Warranty: 12 months
Share
- Fast Delivery
- 24/7 Support
- Quality Assurance
Description
Product Overview
The 1747-L542 is an advanced SLC 5/04 modular processor unit engineered by Allen-Bradley (Rockwell Automation) for the SLC 500 hardware series. Installed in slot zero (0) of compatible modular chassis, this controller features 32 KB of battery-backed user RAM (32,000 words total capacity split into 4K data and 28K program storage) and supports up to 4,096 discrete inputs, 4,096 discrete outputs, and 480 analog I/O points across a maximum of 3 local chassis and 30 slots. Equipped with built-in RS-232 and Data Highway Plus (DH+) communication ports, it delivers rapid performance with a 0.9 ms/K typical program scan time and a backplane current draw of 1 A at 5 V DC and 175 mA at 24 V DC.
Core Technical Advantages
- High I/O Capacity: Manages up to 4,096 discrete inputs, 4,096 discrete outputs, and 480 analog channels across 30 local slots.
- Integrated Dual Communication: Features native RS-232 and Data Highway Plus (DH+) ports for seamless HMI, SCADA, and peer-to-peer messaging.
- Robust Memory & Diagnostics: Combines 32 KB battery-backed RAM (1747-BA) with comprehensive status LEDs for run, fault, battery, and port activity.
Technical Specifications
| Parameter | Specification Details |
|---|---|
| Brand & Manufacturer | Allen-Bradley (Rockwell Automation) |
| Series & Module Type | SLC 500 Series / SLC 5/04 Processor |
| Catalog / Part Number | 1747-L542 |
| User Memory Capacity | 32 KB / 32,000 Words (Battery-Backed RAM) |
| Discrete I/O Points | 4,096 Inputs and 4,096 Outputs (Max) |
| Analog I/O Points | 480 Maximum Local Analog I/O |
| Chassis & Slot Capacity | Max 3 Local Chassis / 30 Slots Total |
| Processing & Scan Times | Program Scan: 0.9 ms/Kword; I/O Scan: 0.225 ms; Bit Execution: 0.37 ms |
| Communication Ports | Data Highway Plus (DH+) and RS-232 |
| Memory Backup Options | Battery Backup (1747-BA) / Flash EPROM (1747-M13) |
| Backplane Current Draw | 1 A at 5 V DC and 175 mA at 24 V DC |
| Operating Ambient Temperature | 0°C to 60°C (32°F to 140°F) |
| Product Net Weight | Approx. 0.45 kg (1.00 lbs) |
Industrial Applications
- Discrete Manufacturing Plants: Coordinates large-scale sequential automation across multi-chassis production lines.
- Process Control & SCADA Nodes: Interfaces local machinery with supervisory HMI and control networks via DH+.
- Legacy System Upgrades: Replaces older SLC 500 processors to expand program memory and communication bandwidth.
Wiring & Installation
- Slot Placement: Insert the 1747-L542 processor securely into Slot Zero (0) of compatible 1746 modular chassis racks.
- Communication Cabling: Connect RS-232 programming cables or Data Highway Plus (DH+) multi-drop network lines to respective ports.
- Power & Battery Check: Ensure system power supply is seated on the far left and verify backup battery (1747-BA) connection.
Engineering Advantages
- High-Speed Execution: 0.37 ms bit execution and fast scan times maintain strict loop control in automated tasks.
- Robust Environmental Tolerance: Operates reliably from 0°C to 60°C with 5% to 95% non-condensing humidity endurance.
- Flexible Networking: Built-in DH+ protocol enables high-speed data exchange with PLC-5 and other Allen-Bradley systems.
Technical FAQs
Q1: What is the total user memory capacity of the Allen-Bradley 1747-L542?
A1: The processor provides 32 KB (32,000 words) of user memory, partitioned into data and program storage.
Q2: Which communication interfaces are integrated into this SLC 5/04 processor?
A2: It features built-in Data Highway Plus (DH+) and RS-232 communication ports.
Q3: What chassis slot must the 1747-L542 processor be installed in?
A3: The controller must be installed directly into Slot Zero (0) of the local modular I/O chassis.
Additional Specifications
- Gray
- Green
- DC-powered
- Modular
Scalar (V/f)
Vector
AC-powered
Buying Guide
- Confirm the exact model, part number, and specifications before ordering.
- Ensure compatibility with your current machinery or control systems.
- Reach out via sale@etowonauto.com or +8617859788089 for technical assistance.
- Review delivery options, lead times, and shipping requirements.
- Follow manufacturer instructions and best practices during installation.
Shipping And Return
In-stock items are typically dispatched the same business day. For products not currently in stock, dispatch times may vary based on availability. International shipping is available, and shipping costs are calculated according to destination, weight, and carrier selection.
Returns are accepted within 30 days of receipt, provided items are unused and in original condition. Return shipping costs are the responsibility of the customer. Please contact us before returning any item to receive return authorization.
For more details, please review our Shipping & Return Policy.

3500/61-05-CN Temperature Monitor Module | Bently Nevada
3500/22-01-02-CN TDI Module Bently Nevada
Bently Nevada 3500/42-04-00 | Seismic Monitor
-
Fast Shipping
Original industrial automation parts available for prompt shipment worldwide.
-
Easy Returns
30-day return support with a 12-month warranty for reliable after-sales protection.
-
24/7 support
Responsive professional support to help maintain stable and efficient operations.
-
Genuine & Original
100% authentic, sourced directly from trusted industrial automation manufacturers.
Technical & Buying Guide
-
What Makes GE Mark VIe the Top Turbine Control DCS?
GE Mark VIe is a high-performance turbine control DCS built for gas and steam power plants. It combines fast scan cyc...
-
What Makes Emerson DeltaV M-Series Ideal for Oil & Gas DCS Control?
Emerson's DeltaV M-Series controller delivers reliable regulatory control for oil and gas assets through MQ and MX va...
-
What Makes Siemens PCS 7 AS410 Ideal for Chemical DCS?
Siemens PCS 7 with the AS410 automation station delivers high availability for continuous chemical manufacturing. Thi...
-
What Causes Most ABB AC800M Migration Failures?
ABB AC800M controllers have run for 12 to 18 years in many plants, and spare part lead times now reach 16 weeks. This...
-
How to Migrate Honeywell TDC3000 to Experion PKS?
This guide explains how process plants can migrate aging Honeywell TDC3000 DCS systems to Experion PKS C300 through p...
-
What Makes PLC and DCS Migration Projects Succeed?
Multi-vendor control system migration demands disciplined project management, early interface testing, and structured...