Transform your home with the latest multi-electronics solutions, from intelligent lighting to vOptimize your operations with the Bently Nevada 3500 Monitoring System, offering real-time vibration and machinery condition monitoring to prevent failures and maximize uptime.oice-controlled devices all designed to make life easier, safer, and more connected.
SKU:1746-NR8
Allen-Bradley 1746-NR8 RTD Module Input SLC 500
Manufacturer: Allen-Bradley
Product No.: 1746-NR8
Product Type: Analog Input Module
Product Origin: USA
Payment:T/T, Western Union
Weight: 280g
Shipping port: Xiamen
Warranty: 12 months
Share
- Fast Delivery
- 24/7 Support
- Quality Assurance
Description
Product Overview
The Allen-Bradley 1746-NR8 is a high-performance RTD (Resistance Temperature Detector) and resistance analog input module for the SLC 500 PLC platform. Equipped with eight independent input channels, this module is engineered for precision temperature monitoring in complex industrial processes. By utilizing advanced Sigma-Delta Modulation for A/D conversion, it achieves an exceptional temperature resolution of 0.01°C. Whether monitoring thermal variations in food processing or managing resistance ranges for heavy machinery, the 1746-NR8 provides the high-density I/O capability required to maintain tight process control.
Technical Configuration
The 1746-NR8 is designed for maximum versatility within an SLC 500 chassis:
- Channel Count: 8 high-accuracy input channels for RTD or direct resistance signals.
- Input Ranges: Supports multiple resistance ranges (0–150 Ω, 0–300 Ω, 0–500 Ω, and 0–1000 Ω).
- Conversion Technology: Sigma-Delta Modulation ensures superior noise rejection and measurement linearity.
- Update Rates: Fully adjustable from 6 ms up to 2 seconds to match application dynamics.
- Slot Compatibility: Installs into any available I/O slot of an SLC 500 chassis (except Slot 0).
Technical Specifications
| Parameter | Specification |
|---|---|
| Temperature Resolution | 0.01°C |
| Step Response Time | 60 ms (In) / 2.5 ms (Out) |
| Backplane Current (5V) | 100 mA |
| Backplane Current (24V) | 55 mA |
| Operating Temperature | 0°C to 60°C (32°F to 140°F) |
| Power Consumption | 1.82 W Maximum |
Installation Guide
To integrate the 1746-NR8 into your SLC 500 system, verify that your power supply has sufficient current capacity for the module's 5V and 24V DC backplane requirements.
Wiring and Shielding
RTD signals are highly sensitive to electrical noise. For optimal precision, use high-quality shielded twisted-pair cable for all sensor connections. Ground the cable shield at the module end only to prevent ground loops. The module supports 2, 3, or 4-wire RTD configurations; however, 3 or 4-wire setups are highly recommended to compensate for lead-wire resistance, which is essential for maintaining the rated 0.01°C resolution. Ensure the module is firmly seated and the chassis lever is locked before applying power.
Engineering Advantages
The 1746-NR8 stands out for its "Precision Performance" profile, offering a step response as fast as 60 ms for dynamic thermal tracking. Despite its advanced circuitry, the module maintains a lightweight profile with a net weight of approximately 0.28 kg, minimizing the physical stress on the backplane connectors. Its wide operating temperature range (0–60°C) makes it resilient in non-conditioned industrial environments. Furthermore, the adjustable update time allows engineers to prioritize either high-speed data acquisition for fast-moving processes or heavy filtering for high-stability measurements in noisy environments.
Technical FAQs
Q1: Can I mix different RTD types on the same module?
A1: Yes, the 1746-NR8 allows you to configure each channel individually through the SLC 500 programming software, supporting various RTD types and resistance ranges simultaneously.
Q2: Why does the module use Sigma-Delta Modulation?
A2: This modulation technique provides excellent high-frequency noise rejection and high resolution, which is critical when dealing with the low-voltage signals produced by RTD sensors.
Q3: Is lead-wire compensation automatic?
A3: The module automatically compensates for lead-wire resistance when using 3-wire or 4-wire sensor configurations, ensuring that only the sensor's resistance is measured.
Additional Specifications
Scalar (V/f)
Vector
AC-powered
Buying Guide
- Confirm the exact model, part number, and specifications before ordering.
- Ensure compatibility with your current machinery or control systems.
- Reach out via sale@etowonauto.com or +8617859788089 for technical assistance.
- Review delivery options, lead times, and shipping requirements.
- Follow manufacturer instructions and best practices during installation.
Shipping And Return
In-stock items are typically dispatched the same business day. For products not currently in stock, dispatch times may vary based on availability. International shipping is available, and shipping costs are calculated according to destination, weight, and carrier selection.
Returns are accepted within 30 days of receipt, provided items are unused and in original condition. Return shipping costs are the responsibility of the customer. Please contact us before returning any item to receive return authorization.
For more details, please review our Shipping & Return Policy.

3500/61-05-CN Temperature Monitor Module | Bently Nevada
3500/22-01-02-CN TDI Module Bently Nevada
Bently Nevada 3500/42-04-00 | Seismic Monitor
-
Fast Shipping
Original industrial automation parts available for prompt shipment worldwide.
-
Easy Returns
30-day return support with a 12-month warranty for reliable after-sales protection.
-
24/7 support
Responsive professional support to help maintain stable and efficient operations.
-
Genuine & Original
100% authentic, sourced directly from trusted industrial automation manufacturers.
Technical & Buying Guide
-
Can DCS Intelligent Regulation Fix Thermal Power Energy Imbalance?
This article explains how intelligent DCS regulation with MPC and cloud-based control solves energy-production imbala...
-
Can Continuous Automation Iteration Cut Factory Costs by 18-25%?
Static industrial control systems create hidden annual cost increases of 18-25%. Phased PLC and DCS program iteration...
-
Can Anti-Interference Hardware End 38% of Automation Downtime?
Field data from chemical, wind, and automotive plants proves that industrial hardware with full IEC 61000-4 EMC certi...
-
How Does Full-Lifecycle Management Optimize PLC and DCS Assets?
Traditional industrial asset management relies on manual logging and reactive troubleshooting, causing 15–20% annual ...
-
Can an Integrated Spare Chain Slash Downtime?
Unplanned equipment failures cost Chinese factories ¥636,000 per hour. Traditional cross-border spare procurement tak...
-
Why Do 30% of Automation Upgrades Fail Due to Integration Gaps?
This technical article explains how digital-intelligent fusion overcomes fragmented workshop operations using industr...