Transform your home with the latest multi-electronics solutions, from intelligent lighting to vOptimize your operations with the Bently Nevada 3500 Monitoring System, offering real-time vibration and machinery condition monitoring to prevent failures and maximize uptime.oice-controlled devices all designed to make life easier, safer, and more connected.
SKU:1746-IM4
Allen-Bradley 1746-IM4 SLC 500 | 4-Point AC Input Module 240V
Manufacturer: Allen-Bradley
Product No.: 1746-IM4
Product Type: AC Input Module
Product Origin: USA
Payment:T/T, Western Union
Weight: 320g
Shipping port: Xiamen
Warranty: 12 months
Share
- Fast Delivery
- 24/7 Support
- Quality Assurance
Description
Product Overview
The Allen-Bradley 1746-IM4 is a 4-channel Digital AC Input Module for the SLC 500 PLC system. It accepts 170-265V AC signals from field devices such as limit switches, pushbuttons, and proximity sensors. This module mounts directly into the 1746 I/O chassis, providing reliable AC input monitoring for general-purpose industrial control applications.
Core Functionality
The 1746-IM4 converts 200-240V AC field signals into logic-level inputs for the SLC 500 processor. Each of the four input channels features a nominal input current of 12mA at 240V AC. Signal delay times are 35ms for ON transitions and 45ms for OFF transitions. Off-state leakage current is limited to 2.0mA maximum, preventing false triggering. Circuit isolation is tested at 1500V AC between the backplane and I/O, protecting the control system from field-side faults.
Technical Specifications
| Parameter | Value |
| Part Number | 1746-IM4 |
| Series | SLC 500 |
| Module Type | Digital AC Input Module |
| Inputs | 4 |
| Voltage Range | 170-265V AC (47-63 Hz) |
| Nominal Input Current | 12mA @ 240V AC |
| Backplane Current (5V DC) | 35 mA |
| Backplane Current (24V DC) | 0 A |
| ON Signal Delay | 35 ms (max) |
| OFF Signal Delay | 45 ms (max) |
| Off-State Leakage Current | 2.0 mA (max) |
| Off-State Voltage Loss | 50V AC (max) |
| Surge Current per Point | 1.6A (500µs duration) |
| Power Dissipation | 1.6W |
| Isolation (Backplane to I/O) | 1500V AC |
| Weight | Approx. 0.32 kg (0.7 lbs) |
| Operating Temperature | 0°C to 60°C (32°F to 140°F) |
| Storage Temperature | -40°C to 85°C (-40°F to 185°F) |
| Humidity | 5-95% (non-condensing) |
| Shock Rating | 30G |
| Vibration Rating | 2.5G (57-500 Hz) |
| Certifications | UL-A196, CSA, C-UL (hazardous locations) |
| Noise Immunity | NEMA ICS 2-230 |
Installation Guide
Install the 1746-IM4 in any available slot of the SLC 500 1746 I/O chassis. Ensure the chassis is powered off before insertion. Align the module with the card guides and push firmly until the connector seats fully with the backplane. Secure the module with the retaining screw. Connect field wiring using 1746-HT or 1746-HCA I/O connection cables. Observe polarity: AC inputs are not polarity-sensitive but maintain consistent wiring practices for troubleshooting.
Engineering Advantages
The 1746-IM4 provides reliable AC input monitoring with 1500V AC isolation, protecting the SLC 500 backplane from field-side transients. The 35ms ON and 45ms OFF delays filter contact bounce and electrical noise, ensuring stable input states. Off-state leakage current of just 2.0mA prevents false triggering from residual current in long cable runs. The module is rated for 30G shock and 2.5G vibration, making it suitable for heavy machinery environments. UL and CSA certifications allow installation in hazardous locations. The lightweight design at approximately 0.32 kg (0.7 lbs) simplifies installation and reduces chassis loading.
Technical FAQs
Q1: Can the 1746-IM4 accept 120V AC inputs?
A1: No. The 1746-IM4 is designed for 170-265V AC (200-240V AC nominal). For 120V AC inputs, use the 1746-IA4 or 1746-IA8 module instead.
Q2: What is the purpose of the 35ms ON delay?
A2: The ON delay filters electrical noise and contact bounce from mechanical switches, preventing false transitions and ensuring stable processor input states.
Q3: Is the 1746-IM4 compatible with 1746 chassis of any series?
A3: Yes. The 1746-IM4 works with all SLC 500 1746-series chassis, including the 1746-A4, A7, A10, and A13 models.
Additional Specifications
Scalar (V/f)
Vector
AC-powered
Buying Guide
- Confirm the exact model, part number, and specifications before ordering.
- Ensure compatibility with your current machinery or control systems.
- Reach out via sale@etowonauto.com or +8617859788089 for technical assistance.
- Review delivery options, lead times, and shipping requirements.
- Follow manufacturer instructions and best practices during installation.
Shipping And Return
In-stock items are typically dispatched the same business day. For products not currently in stock, dispatch times may vary based on availability. International shipping is available, and shipping costs are calculated according to destination, weight, and carrier selection.
Returns are accepted within 30 days of receipt, provided items are unused and in original condition. Return shipping costs are the responsibility of the customer. Please contact us before returning any item to receive return authorization.
For more details, please review our Shipping & Return Policy.

3500/61-05-CN Temperature Monitor Module | Bently Nevada
3500/22-01-02-CN TDI Module Bently Nevada
Bently Nevada 3500/42-04-00 | Seismic Monitor
-
Fast Shipping
Original industrial automation parts available for prompt shipment worldwide.
-
Easy Returns
30-day return support with a 12-month warranty for reliable after-sales protection.
-
24/7 support
Responsive professional support to help maintain stable and efficient operations.
-
Genuine & Original
100% authentic, sourced directly from trusted industrial automation manufacturers.
Technical & Buying Guide
-
Can Full-Cycle Data Recording Solve Hidden PLC and DCS Faults?
This article examines how GE full-cycle data recording addresses the critical blind spots in traditional PLC and DCS ...
-
How Can Smart Sensor Maintenance Cut False Alarms by 71%?
This article presents a data-driven approach to gas sensor lifecycle management for hazardous area monitoring instrum...
-
Can Standardized Engineering Cut Factory Upgrade Costs by 40%?
This article presents a data‑driven alternative to full control system replacements in brown‑field plants. Allen‑Brad...
-
Choosing the Right Gas Detector for Chemical Safety?
This article examines the operational and financial impact of unreliable gas-sensing hardware in chemical process pla...
-
Is Mixed-Plant Data Fragmentation Costing You More?
Hybrid manufacturing facilities often lose nearly one-third of production data across disjointed PLC and DCS systems,...
-
Can Transient Monitoring Prevent Rotating Machinery Failures?
This technical article examines the critical role of transient data capture in rotating machinery protection, highlig...