Transform your home with the latest multi-electronics solutions, from intelligent lighting to vOptimize your operations with the Bently Nevada 3500 Monitoring System, offering real-time vibration and machinery condition monitoring to prevent failures and maximize uptime.oice-controlled devices all designed to make life easier, safer, and more connected.
SKU:1746-IA16
Allen-Bradley 1746-IA16 | 16 Point AC Input 35ms ON Delay
Manufacturer: Allen-Bradley
Product No.: 1746-IA16
Product Type: Digital AC Input Module
Product Origin: USA
Payment:T/T, Western Union
Weight: 340g
Shipping port: Xiamen
Warranty: 12 months
Share
- Fast Delivery
- 24/7 Support
- Quality Assurance
Description
Allen-Bradley 1746-IA16 SLC 500 Digital AC Input Module
Product Overview
The Allen-Bradley 1746-IA16 is a digital AC input module for the SLC 500 controller platform. It features sixteen (16) input channels accepting 85-132 VAC signal voltage. The module occupies a single slot in the SLC 500 chassis and includes a removable terminal block for easy replacement. Weight is 0.34 kg.
Specifications
| Parameter | Value |
|---|---|
| Brand | Allen-Bradley / Rockwell Automation |
| Model | 1746-IA16 |
| Series | SLC 500 |
| Module Type | Digital AC Input Module |
| Inputs | 16 |
| Voltage Range | 85-132 VAC |
| Frequency | 47-63 Hz |
| Input Current (120VAC) | 12 mA nominal |
| Backplane Current (5V) | 85 mA |
| Backplane Current (24V) | 0.0 A |
| Signal Delay ON | 35 ms max |
| Signal Delay OFF | 45 ms max |
| Off-State Current | 2 mA |
| Off-State Voltage Max | 30 VAC |
| Step Response | 100 ms in, 2.5 ms out |
| Inrush Current (Max) | 0.8 mA at 500 µs |
| Slots Required | 1 |
| Power Dissipation | 4.8 W total, 0.27-0.425 W per point |
| Terminals | 20 (Terminals 18-19 common) |
| I/O Connection | 1746-HT, 1746-HCA |
| Mounting | Chassis type (1746 chassis) |
| Dimensions (W x H x D) | 5 x 6 x 2 in (13 x 15 x 5 cm) |
| Weight | 0.34 kg |
Key Features
- 16 digital AC input channels for 85-132 VAC signals
- Single slot SLC 500 chassis installation
- Removable terminal block for easy module replacement
- 20 terminals with internally connected commons (18-19)
- 35 ms ON delay and 45 ms OFF delay
- 85 mA backplane current at 5Vdc
- 12 mA nominal input current at 120VAC
- General-purpose input applications
- Compatible with fixed or modular hardware style controllers
- Local or expansion rack installation
Installation Notes
Install the module in any available slot of the SLC 500 chassis. The module accepts 85-132 VAC at 47-63 Hz. Use 1746-HT or 1746-HCA I/O connections. The removable terminal block allows replacement without rewiring. Ensure AC input devices are compatible with SLC 500 inrush current specifications.
FAQs
Q1: What is the voltage range for the 1746-IA16?
A1: 85-132 VAC at 47-63 Hz.
Q2: How many inputs does this module provide?
A2: Sixteen (16) digital AC input channels.
Q3: What is the signal delay for this module?
A3: 35 ms ON delay max, 45 ms OFF delay max.
Additional Specifications
Scalar (V/f)
Vector
AC-powered
Buying Guide
- Confirm the exact model, part number, and specifications before ordering.
- Ensure compatibility with your current machinery or control systems.
- Reach out via sale@etowonauto.com or +8617859788089 for technical assistance.
- Review delivery options, lead times, and shipping requirements.
- Follow manufacturer instructions and best practices during installation.
Shipping And Return
In-stock items are typically dispatched the same business day. For products not currently in stock, dispatch times may vary based on availability. International shipping is available, and shipping costs are calculated according to destination, weight, and carrier selection.
Returns are accepted within 30 days of receipt, provided items are unused and in original condition. Return shipping costs are the responsibility of the customer. Please contact us before returning any item to receive return authorization.
For more details, please review our Shipping & Return Policy.

3500/61-05-CN Temperature Monitor Module | Bently Nevada
3500/22-01-02-CN TDI Module Bently Nevada
Bently Nevada 3500/42-04-00 | Seismic Monitor
-
Fast Shipping
Original industrial automation parts available for prompt shipment worldwide.
-
Easy Returns
30-day return support with a 12-month warranty for reliable after-sales protection.
-
24/7 support
Responsive professional support to help maintain stable and efficient operations.
-
Genuine & Original
100% authentic, sourced directly from trusted industrial automation manufacturers.
Technical & Buying Guide
-
What Makes S7-400H Redundant PLC Ideal for Power Auxiliary Control?
Siemens S7-400H redundant PLC delivers proven hot standby performance for power auxiliary control. This guide covers ...
-
What Makes Honeywell HC900 Ideal for Fine Chemical Batch Control?
This technical guide examines the Honeywell ControlEdge HC900 hybrid PLC/DCS platform for fine chemical batch manufac...
-
How Does the Bently Nevada 1900 Protect Industrial Fans?
This article reviews the Bently Nevada 1900 vibration monitor for industrial fan assets, covering hardware specificat...
-
How Does ABB Ability 800xA Improve Power Plant Automation?
ABB Ability 800xA remains a leading distributed control system for heavy continuous process plants in power and chemi...
-
How Does Emerson Ovation DCS Improve Turbine-Boiler Control?
Emerson Ovation DCS delivers fast scan cycles, redundant controllers, and advanced feed-forward logic for turbin...
-
How Do You Migrate Siemens S7-300/400 to S7-1500?
This guide explains how to migrate Siemens S7-300/400 PLCs to the S7-1500 platform using TIA Portal, covering perform...