Transform your home with the latest multi-electronics solutions, from intelligent lighting to vOptimize your operations with the Bently Nevada 3500 Monitoring System, offering real-time vibration and machinery condition monitoring to prevent failures and maximize uptime.oice-controlled devices all designed to make life easier, safer, and more connected.
SKU:9905-970
9905-970 Input Module | Woodward LinkNet System
Manufacturer: Woodward
Product No.: 9905-970
Product Type: Input Module
Product Origin: USA
Payment:T/T, Western Union
Weight: 2700g
Shipping port: Xiamen
Warranty: 12 months
Share
- Fast Delivery
- 24/7 Support
- Quality Assurance
Description
Woodward 9905-970 LinkNet 6-Channel Input Module
The Woodward 9905-970 is a versatile input module for LinkNet systems. This 6-channel module handles analog and digital signals. It provides reliable data acquisition in harsh industrial environments. The 9905-970 ensures accurate measurement for engine and turbine control applications.
Module Identification
- Manufacturer: Woodward Governor Company
- Part Number: 9905-970 input module
- Product Type: LinkNet 6-Channel Input Module
- System Compatibility: Woodward LinkNet networks
- Mounting Style: Panel mount installation
Electrical Specifications
- Input Voltage: 24 V DC nominal operation
- Maximum Current: 12 A operating capacity
- Transient Protection: 900 V DC surge protection
- Input Impedance: 33K Ohms signal impedance
- Input Channels: 6 independent input points
- Signal Types: Analog and digital inputs
- RTD Support: 100 Ohm RTD compatibility
Physical Specifications
- Dimensions: 14 x 11 x 4 inches (LxWxH)
- Weight: 6 lbs (2.7 kg) approximate
- Display: 24-character LED indicators
- LED Functions: Power, Status, Fault indication
- Protection Rating: IP67 optional (verify specific)
Environmental Specifications
- Operating Temperature: -40°C to +85°C range
- Communication: LinkNet protocol interface
- Construction: Industrial-grade components
- Installation: Panel or enclosure mounting
Installation Guidelines
- Mount on industrial panel in protected enclosure
- Connect 24V DC power supply within specifications
- Wire field signals to appropriate input channels
- Configure LinkNet communication parameters
- Set up RTD or analog input scaling as required
- Verify proper grounding and shielding
Input Channel Configuration
- Channel Count: Six configurable inputs
- Signal Types: Voltage, current, RTD, digital
- Impedance Matching: 33K Ohms input design
- Isolation: Channel-to-channel separation
- Calibration: Field-adjustable settings
Frequently Asked Questions (FAQ)
What signals can the 9905-970 module accept?
The 9905-970 accepts analog voltages, RTD signals, and digital inputs across six channels.
How does the transient protection work?
It provides 900V DC surge protection against power line spikes and transients.
Can this module operate in outdoor installations?
With optional IP67 rating, it can handle harsh environments when properly enclosed.
What is the purpose of the 24-character display?
The LED display shows channel values, status messages, and fault codes.
How do I communicate with this module?
Use Woodward's LinkNet protocol through the communication interface.
What maintenance does this module require?
Periodic calibration verification and environmental inspection are recommended.
For technical support or to order the 9905-970, email sale@etowonauto.com.
Content provided by Etowon Auto.
Additional Specifications
Scalar (V/f)
Vector
AC-powered
Buying Guide
- Confirm the exact model, part number, and specifications before ordering.
- Ensure compatibility with your current machinery or control systems.
- Reach out via sale@etowonauto.com or +8617859788089 for technical assistance.
- Review delivery options, lead times, and shipping requirements.
- Follow manufacturer instructions and best practices during installation.
Shipping And Return
In-stock items are typically dispatched the same business day. For products not currently in stock, dispatch times may vary based on availability. International shipping is available, and shipping costs are calculated according to destination, weight, and carrier selection.
Returns are accepted within 30 days of receipt, provided items are unused and in original condition. Return shipping costs are the responsibility of the customer. Please contact us before returning any item to receive return authorization.
For more details, please review our Shipping & Return Policy.

3500/61-05-CN Temperature Monitor Module | Bently Nevada
3500/22-01-02-CN TDI Module Bently Nevada
Bently Nevada 3500/42-04-00 | Seismic Monitor
-
Fast Shipping
Original industrial automation parts available for prompt shipment worldwide.
-
Easy Returns
30-day return support with a 12-month warranty for reliable after-sales protection.
-
24/7 support
Responsive professional support to help maintain stable and efficient operations.
-
Genuine & Original
100% authentic, sourced directly from trusted industrial automation manufacturers.
Technical & Buying Guide
-
How Do PLC and DCS Transform Modern Warehouse Automation?
This article explores how programmable logic controllers (PLCs) and distributed control systems (DCS) work together t...
-
How Do PLC and DCS Improve Coal-Fired Power Plant Automation?
This article examines the evolving role of PLC and DCS technologies in modern coal-fired power plants. It covers hybr...
-
Which Automation Strategies Deliver the Best Energy Savings?
Intelligent control systems are transforming industrial energy management through demand-responsive scheduling, seque...
-
What Are the Real-World Benefits of Edge Computing with PLCs?
Integrating programmable logic controllers with edge computing transforms industrial automation by processing data di...
-
Why Choose Power Line Communication for Grid Modernization?
This article examines how Power Line Communication (PLC) technology enables reliable, cost-effective data transmiss...
-
How Do PLC and DCS Architectures Optimize Automotive Assembly Lines?
This technical article examines how Programmable Logic Controllers (PLC) and Distributed Control Systems (DCS) functi...