Transform your home with the latest multi-electronics solutions, from intelligent lighting to vOptimize your operations with the Bently Nevada 3500 Monitoring System, offering real-time vibration and machinery condition monitoring to prevent failures and maximize uptime.oice-controlled devices all designed to make life easier, safer, and more connected.
SKU:MDO53
369B1844G5004 GE MDO53 Output Module 16 Channel 24V
Manufacturer: General Electric
Product No.: MDO53
Product Type: Digital Output Module
Product Origin: USA
Payment:T/T, Western Union
Weight: 400g
Shipping port: Xiamen
Warranty: 12 months
Share
- Fast Delivery
- 24/7 Support
- Quality Assurance
Description
GE MDO53 369B1844G5004 Digital Output Module
The GE MDO53 (369B1844G5004) is a 16-channel digital output module with AC relay outputs. Each channel provides 12A @ 250V AC (resistive) and 7.5A @ 250V AC (inductive) contact capacity. Operating on 24 V DC / 100 mA control signal, this module features channel output LED indicators and comprehensive diagnostics. Weighing 0.4 kg (0.88 lbs), it measures 49 x 14 x 2.7 cm.
Technical Specifications
| Parameter | Value |
|---|---|
| Manufacturer | GE |
| Model | MDO53 (369B1844G5004) |
| Product Type | Digital Output Module |
| Output Channels | 16 AC Relay Outputs |
| Control Signal | 24 V DC / 100 mA |
| Contact Rating (Resistive) | 12A @ 250V AC, 12A @ 30V DC |
| Contact Rating (Inductive) | 7.5A @ 250V AC, 6A @ 30V DC |
| Isolation Voltage (Channel-Channel) | 1000V AC |
| Isolation Voltage (Channel-Ground) | 2500V AC |
| Isolation Voltage (Channel-System) | 3000V AC |
| Power Consumption (Typical) | 1.3 W |
| Power Consumption (Maximum) | 11 W |
| Dimensions (W x H x D) | 49 x 14 x 2.7 cm (19.3 x 5.5 x 1.1 in) |
| Weight | 0.4 kg (0.88 lbs) |
| LED Indicators | Channel Output, Run Status, Communication, Fault Alarm |
| Certification | CE (with system) |
Installation & Field Application Guide
- Mount the module in the designated Nexus system slot. Ensure proper backplane connection.
- Wire AC/DC loads to the 16 relay output terminals. Observe contact rating limits for resistive and inductive loads.
- For inductive loads, install external suppression (RC snubbers or MOVs) across each contact.
- Monitor LED indicators for channel status (output on/off), module run, communication, and fault conditions.
Why Choose the MDO53 Module
- 16 relay outputs with 12A contact capacity for heavy AC/DC loads.
- High isolation (3000V AC channel-system) ensures safety in industrial environments.
- Comprehensive LED diagnostics simplify troubleshooting and maintenance.
- CE certified for compliance with European standards.
Field Engineer FAQs
Q1: What is the maximum switching frequency for the relay outputs?
A1: The relay outputs are rated for mechanical life of 10 million operations and electrical life of 100,000 operations at rated load. Maximum switching frequency is 360 operations per hour at rated load.
Q2: Can I mix AC and DC loads on the same module?
A2: Yes, each channel can independently switch AC or DC loads within the rated contact capacity.
Q3: What is the recommended external suppression for inductive loads?
A3: For AC inductive loads, use an RC snubber (0.1µF + 100Ω). For DC inductive loads, use a freewheeling diode across the load.
Inquiries: sale@etowonauto.com
Additional Specifications
Scalar (V/f)
Vector
AC-powered
Buying Guide
- Confirm the exact model, part number, and specifications before ordering.
- Ensure compatibility with your current machinery or control systems.
- Reach out via sale@etowonauto.com or +8617859788089 for technical assistance.
- Review delivery options, lead times, and shipping requirements.
- Follow manufacturer instructions and best practices during installation.
Shipping And Return
In-stock items are typically dispatched the same business day. For products not currently in stock, dispatch times may vary based on availability. International shipping is available, and shipping costs are calculated according to destination, weight, and carrier selection.
Returns are accepted within 30 days of receipt, provided items are unused and in original condition. Return shipping costs are the responsibility of the customer. Please contact us before returning any item to receive return authorization.
For more details, please review our Shipping & Return Policy.

3500/61-05-CN Temperature Monitor Module | Bently Nevada
3500/22-01-02-CN TDI Module Bently Nevada
Bently Nevada 3500/42-04-00 | Seismic Monitor
-
Fast Shipping
Original industrial automation parts available for prompt shipment worldwide.
-
Easy Returns
30-day return support with a 12-month warranty for reliable after-sales protection.
-
24/7 support
Responsive professional support to help maintain stable and efficient operations.
-
Genuine & Original
100% authentic, sourced directly from trusted industrial automation manufacturers.
Technical & Buying Guide
-
How to Diagnose Yokogawa CENTUM VP FCS Redundancy Faults?
This article explains how industrial automation teams can diagnose and debug Yokogawa CENTUM VP FCS controller redund...
-
How Does Siemens S7-1500 PLC Handle PROFINET Real-Time Jitter?
This article examines measurable PROFINET fault modes on Siemens S7-1500 PLC controllers and provides field-prov...
-
Why Do ABB AC800M Redundancy Mismatch Faults Keep Returning?
ABB AC800M redundancy mismatch faults account for 42.7 percent of controller alarms in 800xA systems. Most stem ...
-
How Does Honeywell C300 Improve on C200 DCS Controllers?
Honeywell C300 controllers deliver major gains over C200 in memory, scan speed, redundancy switching, and reliability...
-
How Does the 1756-RM2 Redundancy Module Work?
This article explains how to install, configure and tune the Allen-Bradley 1756-RM2 redundancy module for Contro...
-
How Do You Migrate DeltaV Classic DCS Without Plant Shutdown?
This article explains why Emerson DeltaV Classic systems reach technical limits after 15 to 20 years and how plants c...
