Transform your home with the latest multi-electronics solutions, from intelligent lighting to vOptimize your operations with the Bently Nevada 3500 Monitoring System, offering real-time vibration and machinery condition monitoring to prevent failures and maximize uptime.oice-controlled devices all designed to make life easier, safer, and more connected.
SKU:CC-PDIH01
32-Channel CC-PDIH01 Digital Input Module Honeywell
Manufacturer: Honeywell
Product No.: CC-PDIH01
Product Type: Input Module
Product Origin: USA
Payment:T/T, Western Union
Weight: 440g
Shipping port: Xiamen
Warranty: 12 months
Share
- Fast Delivery
- 24/7 Support
- Quality Assurance
Description
Key features & benefits
- High-density digital input module for Series C I/O systems.
- 32 input channels for efficient status monitoring.
- Accepts 24V DC nominal input signals with 5mA typical current.
- 500V DC channel-to-ground isolation for noise immunity.
- 3.5ms typical response time for fast event detection.
Technical specifications
- Brand & model: Honeywell CC-PDIH01
- Type: 32-Channel Digital Input Module
- Series: Series C I/O
- Input channels: 32
- Input voltage: 24V DC nominal (0-30V DC range)
- Input current: 5mA typical per channel
- Isolation: 500V DC channel-to-ground
- ON state threshold: >15V DC
- OFF state threshold: <5V DC
- Response time: 3.5ms typical
- Power consumption: 5W typical
- Operating temperature: 0 to +60°C
- Storage temperature: -40 to +85°C
- Humidity: 5-95% non-condensing
- Certifications: CE, UL, CSA
- Dimensions: 125 × 50 × 150mm
- Weight: 0.44kg
- Availability: In stock
Installation guide
- Mount Honeywell CC-PDIH01 onto Series C I/O baseplate.
- Connect field wiring to compatible termination assembly (sold separately).
- Configure input mapping via Experion control builder.
- Module self-diagnostics verify channel status continuously.
- Power down rack before installation or removal.
Package contents
- 1× Honeywell CC-PDIH01 digital input module (0.44kg)
- 1× installation manual
- 1× warranty document
FAQ
-
What is CC-PDIH01?
32-channel digital input module for Honeywell Experion PKS Series C. Accepts 24V DC signals with 3.5ms response. Weight 0.44kg. In stock. -
What systems is it compatible with?
Integrates with Honeywell Experion PKS, TDC 3000, and PlantScape systems requiring Series C I/O racks. -
What is the availability?
CC-PDIH01 is currently in stock and available for immediate worldwide shipping via FedEx, UPS, or DHL.
Additional Specifications
- Gray
Scalar (V/f)
Vector
AC-powered
Buying Guide
- Confirm the exact model, part number, and specifications before ordering.
- Ensure compatibility with your current machinery or control systems.
- Reach out via sale@etowonauto.com or +8617859788089 for technical assistance.
- Review delivery options, lead times, and shipping requirements.
- Follow manufacturer instructions and best practices during installation.
Shipping And Return
In-stock items are typically dispatched the same business day. For products not currently in stock, dispatch times may vary based on availability. International shipping is available, and shipping costs are calculated according to destination, weight, and carrier selection.
Returns are accepted within 30 days of receipt, provided items are unused and in original condition. Return shipping costs are the responsibility of the customer. Please contact us before returning any item to receive return authorization.
For more details, please review our Shipping & Return Policy.

3500/61-05-CN Temperature Monitor Module | Bently Nevada
3500/22-01-02-CN TDI Module Bently Nevada
Bently Nevada 3500/42-04-00 | Seismic Monitor
-
Fast Shipping
Original industrial automation parts available for prompt shipment worldwide.
-
Easy Returns
30-day return support with a 12-month warranty for reliable after-sales protection.
-
24/7 support
Responsive professional support to help maintain stable and efficient operations.
-
Genuine & Original
100% authentic, sourced directly from trusted industrial automation manufacturers.
Technical & Buying Guide
-
How does hierarchical control raise factory OEE from 64% to 82%?
This article explains how hierarchical cloud-edge collaborative control replaces fragmented industrial architectures....
-
Can DCS Intelligent Regulation Fix Thermal Power Energy Imbalance?
This article explains how intelligent DCS regulation with MPC and cloud-based control solves energy-production imbala...
-
Can Continuous Automation Iteration Cut Factory Costs by 18-25%?
Static industrial control systems create hidden annual cost increases of 18-25%. Phased PLC and DCS program iteration...
-
Can Anti-Interference Hardware End 38% of Automation Downtime?
Field data from chemical, wind, and automotive plants proves that industrial hardware with full IEC 61000-4 EMC certi...
-
How Does Full-Lifecycle Management Optimize PLC and DCS Assets?
Traditional industrial asset management relies on manual logging and reactive troubleshooting, causing 15–20% annual ...
-
Can an Integrated Spare Chain Slash Downtime?
Unplanned equipment failures cost Chinese factories ¥636,000 per hour. Traditional cross-border spare procurement tak...