Transform your home with the latest multi-electronics solutions, from intelligent lighting to vOptimize your operations with the Bently Nevada 3500 Monitoring System, offering real-time vibration and machinery condition monitoring to prevent failures and maximize uptime.oice-controlled devices all designed to make life easier, safer, and more connected.
SKU:1794-PS3
1794-PS3 Allen-Bradley Flex I/O Power Supply 24VDC 3A
Manufacturer: Allen-Bradley
Product No.: 1794-PS3
Product Type: Power Supply
Product Origin: USA
Payment:T/T, Western Union
Weight: 450g
Shipping port: Xiamen
Warranty: 12 months
Share
- Fast Delivery
- 24/7 Support
- Quality Assurance
Description
Allen-Bradley 1794-PS3 Flex I/O Power Supply
Product Overview
The Allen-Bradley 1794-PS3 is a Flex I/O power supply module providing 24 VDC nominal output at 3 A (horizontal mounting) or 2.8 A (other mountings) with 72 W output power. It accepts 85-264 VAC input (47-63 Hz) and delivers sufficient surge to drive up to 10 adapters. The module features 2500 VDC isolation and 40 A typical inrush current. Weight is 0.45 kg.
Specifications
| Parameter | Value |
|---|---|
| Brand | Allen-Bradley / Rockwell Automation |
| Model | 1794-PS3 |
| Product Family | Flex I/O System |
| Product Type | Flex I/O DC Power Supply Module |
| Input Voltage Range | 85-264 VAC |
| Input Frequency Range | 47-63 Hz |
| Nominal Input Voltage | 120 VAC (1.7 A max) / 230 VAC (1.1 A max) |
| Maximum Input Current | 1.9 A |
| Inrush Current | 40 A Typical, 1 AC Cycle @ 265 VAC, 55 °C |
| Output Voltage | 24 VDC Nominal |
| Output Voltage Range | 20.4-27.6 VDC |
| Output Current (Horizontal) | 3 A |
| Output Current (Other) | 2.8 A |
| Output Power | 72 W |
| Output Surge | Sufficient to Drive 10 Adapters |
| Output Ripple | 1200 mV Peak-to-Peak (±5%) |
| Overcurrent Protection | 3.2 A |
| Overvoltage Protection | 35 VDC |
| Isolation Voltage | 2500 VDC |
| Minimum Load | 50 mA |
| Leakage Current | 0.5 mA RMS Max |
| Power Dissipation | 12 W Max |
| Thermal Dissipation | 41.0 BTU/hr |
| Hold-Up Time | 1/2 Cycle @ 47 Hz, 85 VAC, Max Load |
| Input Power | 86 W |
| Max Apparent Input Power | 205 VA |
| Max Transformer Load | 250 VA |
| Dimensions (H x W x D) | 3.7 x 2.7 x 3.4 in |
| Enclosure Type | Open Style |
| Mounting | DIN Rail or Panel Mount (Horizontal/Vertical) |
| Operating Temperature | 0 to +55 °C |
| Operating Shock | 30g |
| Operating Vibration | 5g @ 10-500 Hz |
| Weight | 0.45 kg |
| UPC | 10612598206626 |
Key Features
- Wide input voltage range 85-264 VAC, 47-63 Hz
- 24 VDC nominal output at 3 A (horizontal) or 2.8 A (other mountings)
- 72 W output power with 1200 mV peak-to-peak ripple
- Output surge sufficient to drive up to 10 adapters
- 2500 VDC isolation between AC input and DC output
- 40 A typical inrush current handling
- 3.2 A overcurrent protection and 35 VDC overvoltage protection
- Hold-up time of 1/2 cycle at 47 Hz, 85 VAC with max load
- DIN rail or panel mount in horizontal or vertical orientation
- 30g operating shock and 5g vibration resistance
Installation Notes
Mount the power supply using DIN rail or panel mount in horizontal or vertical orientation. Horizontal mounting allows 3 A output current, while other orientations support 2.8 A. Connect 85-264 VAC input at 47-63 Hz. The output provides 24 VDC nominal to power Flex I/O modules and adapters. Maintain minimum load of 50 mA. The unit supports up to 10 Flex I/O adapters through its output surge capability. Maintain operating temperature between 0 and +55 °C. Ensure proper isolation between DC output terminals and AC input terminals.
FAQs
Q1: What is the output power of the 1794-PS3?
A1: 72 W with 3 A output current at horizontal mounting or 2.8 A at other mountings.
Q2: How many adapters can this power supply drive?
A2: Output surge is sufficient to drive up to 10 Flex I/O adapters.
Q3: What is the inrush current rating?
A3: 40 A typical for 1 AC cycle at 265 VAC and 55 °C.
Additional Specifications
- Gray
- AC-powered
Scalar (V/f)
Vector
AC-powered
Buying Guide
- Confirm the exact model, part number, and specifications before ordering.
- Ensure compatibility with your current machinery or control systems.
- Reach out via sale@etowonauto.com or +8617859788089 for technical assistance.
- Review delivery options, lead times, and shipping requirements.
- Follow manufacturer instructions and best practices during installation.
Shipping And Return
In-stock items are typically dispatched the same business day. For products not currently in stock, dispatch times may vary based on availability. International shipping is available, and shipping costs are calculated according to destination, weight, and carrier selection.
Returns are accepted within 30 days of receipt, provided items are unused and in original condition. Return shipping costs are the responsibility of the customer. Please contact us before returning any item to receive return authorization.
For more details, please review our Shipping & Return Policy.

3500/61-05-CN Temperature Monitor Module | Bently Nevada
3500/22-01-02-CN TDI Module Bently Nevada
Bently Nevada 3500/42-04-00 | Seismic Monitor
-
Fast Shipping
Original industrial automation parts available for prompt shipment worldwide.
-
Easy Returns
30-day return support with a 12-month warranty for reliable after-sales protection.
-
24/7 support
Responsive professional support to help maintain stable and efficient operations.
-
Genuine & Original
100% authentic, sourced directly from trusted industrial automation manufacturers.
Technical & Buying Guide
-
What Makes Emerson DeltaV M-Series Ideal for Oil & Gas DCS Control?
Emerson's DeltaV M-Series controller delivers reliable regulatory control for oil and gas assets through MQ and MX va...
-
What Makes Siemens PCS 7 AS410 Ideal for Chemical DCS?
Siemens PCS 7 with the AS410 automation station delivers high availability for continuous chemical manufacturing. Thi...
-
What Causes Most ABB AC800M Migration Failures?
ABB AC800M controllers have run for 12 to 18 years in many plants, and spare part lead times now reach 16 weeks. This...
-
How to Migrate Honeywell TDC3000 to Experion PKS?
This guide explains how process plants can migrate aging Honeywell TDC3000 DCS systems to Experion PKS C300 through p...
-
What Makes PLC and DCS Migration Projects Succeed?
Multi-vendor control system migration demands disciplined project management, early interface testing, and structured...
-
How Does GE OPC UA Server Connect Mixed PLC and DCS Systems?
GE OPC UA server helps industrial plants unify fragmented PLC and DCS data through a vendor-neutral standard, coverin...