Transform your home with the latest multi-electronics solutions, from intelligent lighting to vOptimize your operations with the Bently Nevada 3500 Monitoring System, offering real-time vibration and machinery condition monitoring to prevent failures and maximize uptime.oice-controlled devices all designed to make life easier, safer, and more connected.
SKU:1794-ACN15
1794-ACN15 | Allen-Bradley ControlNet Communication Interface
Manufacturer: Allen-Bradley
Product No.: 1794-ACN15
Product Type: Adapter Module
Product Origin: USA
Payment:T/T, Western Union
Weight: 320g
Shipping port: Xiamen
Warranty: 12 months
Share
- Fast Delivery
- 24/7 Support
- Quality Assurance
Description
Allen-Bradley 1794-ACN15 FLEX I/O ControlNet Adapter Module
Product Overview
The 1794-ACN15 is a high-performance ControlNet adapter designed for the Allen-Bradley FLEX I/O system. This module serves as a critical communication bridge, allowing FLEX I/O modules to interface seamlessly with a ControlNet network. Supporting a consistent 5 Mbps communication rate, it ensures rapid and deterministic data exchange for complex automated systems. Its modular design allows for a high degree of I/O density, making it an essential component for distributed control architectures in high-speed industrial environments.
Core Technical Advantages
Engineered by Rockwell Automation, this adapter operates on a standard 24V DC power supply and is built to handle the rigorous demands of industrial automation. It features a robust Flexbus output current of up to 640 mA, providing ample power to the connected I/O modules. One of its standout features is the high isolation voltage rating of 850 Volts DC, which protects the network integrity and logic from electrical disturbances. With an inrush current capacity of 23A for 2 milliseconds, the module is designed to start reliably even in fully loaded system configurations.
Technical Specifications
| Feature | Specification |
|---|---|
| Brand | Allen-Bradley (Rockwell Automation) |
| Catalog Number | 1794-ACN15 |
| Communication Rate | 5 Mbps |
| Flexbus Output | 640 mA maximum |
| Product Weight | Approx. 0.32 kg (0.71 lbs) |
| Isolation Voltage | 850V DC |
| Wiring size | 22 to 12 AWG (Solid or Stranded) |
Installation & Engineering Guide
For optimal signal integrity, the module should be connected using Belden RG-6/U or an equivalent high-quality ControlNet coaxial cable. The flexible wiring options allow for single or double wire connections, accommodating a variety of copper wire sizes from 22 to 12 AWG. Ensure that the 24V DC supply is stable, as the module’s power dissipation is rated at 4.6W maximum at 19.2V DC. The adapter supports up to eight FLEX I/O modules; however, engineers must verify that the total backplane current does not exceed the 640 mA Flexbus limit to ensure long-term reliability and module performance.
Engineering Advantages
The FLEX I/O architecture is renowned for reducing installation costs and panel space. This module maintains a compact physical profile with a shipping weight of approximately 0.32 kg, making it easy to integrate into existing ControlNet architectures. Its high level of isolation and low power consumption make it ideal for decentralized control applications in oil and gas, food and beverage, and automotive manufacturing. By leveraging the 5 Mbps bandwidth, this adapter facilitates real-time diagnostics and control, significantly improving asset uptime and reducing troubleshooting complexities in critical industrial processes.
Technical FAQs
Q1: What is the difference between ACN and ACN15 models?
A1: The 1794-ACN15 is a standard ControlNet adapter, while the '15' designation typically refers to specific firmware or series enhancements for improved compatibility with modern FLEX I/O racks.
Q2: Does this module support redundant ControlNet media?
A2: No, the 1794-ACN15 is a non-redundant media adapter. For applications requiring redundant media ports, the 1794-ACNR15 should be used.
Q3: Can I use this adapter with any FLEX I/O module?
A3: Yes, it is compatible with the vast majority of 1794 FLEX I/O digital, analog, and specialty modules, provided the backplane power budget is respected.
Additional Specifications
Scalar (V/f)
Vector
AC-powered
Buying Guide
- Confirm the exact model, part number, and specifications before ordering.
- Ensure compatibility with your current machinery or control systems.
- Reach out via sale@etowonauto.com or +8617859788089 for technical assistance.
- Review delivery options, lead times, and shipping requirements.
- Follow manufacturer instructions and best practices during installation.
Shipping And Return
In-stock items are typically dispatched the same business day. For products not currently in stock, dispatch times may vary based on availability. International shipping is available, and shipping costs are calculated according to destination, weight, and carrier selection.
Returns are accepted within 30 days of receipt, provided items are unused and in original condition. Return shipping costs are the responsibility of the customer. Please contact us before returning any item to receive return authorization.
For more details, please review our Shipping & Return Policy.

3500/61-05-CN Temperature Monitor Module | Bently Nevada
3500/22-01-02-CN TDI Module Bently Nevada
Bently Nevada 3500/42-04-00 | Seismic Monitor
-
Fast Shipping
Original industrial automation parts available for prompt shipment worldwide.
-
Easy Returns
30-day return support with a 12-month warranty for reliable after-sales protection.
-
24/7 support
Responsive professional support to help maintain stable and efficient operations.
-
Genuine & Original
100% authentic, sourced directly from trusted industrial automation manufacturers.
Technical & Buying Guide
-
Dual Compliance Standards for Pharma Automation?
This article presents a quantified engineering methodology for explosion-proof PLC and DCS system design in GMP-certi...
-
How to Avoid Bulk Sourcing Risks for Power Plant Control Spares?
This guide presents field-validated strategies for bulk sourcing industrial control spares in power plants. It q...
-
What Are the Hidden Costs of Fake PLC and DCS Modules?
This guide presents data-driven verification protocols for imported industrial control spare parts, addressing the es...
-
Redundant PLC + DCS: 18.6% Fan Energy Savings?
This case study documents a full automation retrofit for a 300 TPD waste incineration plant. By integrating Emerson D...
-
Can Proper Warehousing Cut Automation Hardware Failures 80%?
This technical guide presents quantified storage and maintenance standards for industrial PLC, DCS, and TSI spare par...
-
Can Industrial Control Upgrades Cut Unplanned Downtime by 90%?
This article examines why legacy PLC, DCS, and vibration monitoring systems demand urgent retrofit in 2026. Citing re...
