Transform your home with the latest multi-electronics solutions, from intelligent lighting to vOptimize your operations with the Bently Nevada 3500 Monitoring System, offering real-time vibration and machinery condition monitoring to prevent failures and maximize uptime.oice-controlled devices all designed to make life easier, safer, and more connected.
SKU:1762-L40AWA
1762-L40AWA Allen-Bradley Controller | 120VAC Input 1440VA Load
Manufacturer: Allen-Bradley
Product No.: 1762-L40AWA
Product Type: Controller Module
Product Origin: USA
Payment:T/T, Western Union
Weight: 1090g
Shipping port: Xiamen
Warranty: 12 months
Share
- Fast Delivery
- 24/7 Support
- Quality Assurance
Description
Allen-Bradley 1762-L40AWA MicroLogix 1200 Controller
Product Overview
The Allen-Bradley 1762-L40AWA is a 40-point programmable controller from the MicroLogix 1200 series. It features 24 inputs rated at 120 VAC and 16 relay outputs with a 24-125 VDC / 120-240 VAC contact rating. Powered by 120-240 VAC external supply, the controller includes 2 trim potentiometers for local control and one 8-pin mini-DIN communication port. Weight is 2.4 lbs (1.09 kg).
Specifications
| Parameter | Value |
|---|---|
| Brand | Allen-Bradley / Rockwell Automation |
| Model | 1762-L40AWA |
| Series | MicroLogix 1200 |
| Module Type | Programmable Controller |
| Input Power | 120-240 VAC, 47-63 Hz |
| Inputs | 24 (120 VAC) |
| Outputs | 16 Relay |
| Relay Contact Rating | 24-125 VDC; 120-240 VAC |
| Mechanical Cycles | 20,000,000 |
| Load Current | 10 A minimum |
| Max Load Capacity | 1,440 VA |
| Current per Group Common | 8 A |
| On-State Voltage (Ch 0-3) | 14-24 VDC |
| On-State Voltage (Ch 4+) | 10-24 VDC |
| Off-State Voltage | 0-5 VDC |
| Min Off-State Leakage | 1.5 mA |
| Communication Port | 1 x 8-Pin mini-DIN |
| Supported Protocols | DF1, DH-485, ASCII, MODBUS |
| Power Supply Usage | 82 VA |
| Inrush Current (120V AC) | 25 A for 8 ms |
| Inrush Current (240V AC) | 40 A for 4 ms |
| Dimensions (H x W x D) | 90 x 160 x 87 mm (104 mm with DIN latch open) |
| Operating Temperature | 0 to 55 °C |
| Weight | 2.4 lbs (1.09 kg) |
| UPC | 10612598207227 |
Key Features
- 40-point controller with 24 inputs and 16 relay outputs
- 120 VAC input rating with 120-240 VAC power supply
- Relay contact rating 24-125 VDC / 120-240 VAC
- 20,000,000 mechanical cycle relay rating
- Max load capacity 1,440 VA with 8 A per group common
- Two trim potentiometers for local control
- One 8-pin mini-DIN communication port
- Supports DF1, DH-485, ASCII, and MODBUS protocols
- Operating frequency 47-63 Hz
- Compact design with 2-inch clearance requirement
Installation Notes
Supply external 100-240 VAC power at 47-63 Hz. Ensure output load does not exceed 8 A per group common to prevent module damage. The inrush current is 25 A for 8 ms at 120 VAC and 40 A for 4 ms at 240 VAC. Use the 8-pin mini-DIN port for program download/upload, HMI, and SCADA interfacing. Trim potentiometers located on the front panel can be adjusted with a precision screwdriver for local control.
FAQs
Q1: How many I/O points does the 1762-L40AWA have?
A1: 24 inputs (120 VAC) and 16 relay outputs, totaling 40 I/O channels.
Q2: What is the maximum load capacity?
A2: Up to 1,440 VA, with a maximum of 8 A per group common.
Q3: What communication protocols are supported?
A3: DF1, DH-485, ASCII, and MODBUS Master/Slave protocol.
Additional Specifications
Scalar (V/f)
Vector
AC-powered
Buying Guide
- Confirm the exact model, part number, and specifications before ordering.
- Ensure compatibility with your current machinery or control systems.
- Reach out via sale@etowonauto.com or +8617859788089 for technical assistance.
- Review delivery options, lead times, and shipping requirements.
- Follow manufacturer instructions and best practices during installation.
Shipping And Return
In-stock items are typically dispatched the same business day. For products not currently in stock, dispatch times may vary based on availability. International shipping is available, and shipping costs are calculated according to destination, weight, and carrier selection.
Returns are accepted within 30 days of receipt, provided items are unused and in original condition. Return shipping costs are the responsibility of the customer. Please contact us before returning any item to receive return authorization.
For more details, please review our Shipping & Return Policy.

3500/61-05-CN Temperature Monitor Module | Bently Nevada
3500/22-01-02-CN TDI Module Bently Nevada
Bently Nevada 3500/42-04-00 | Seismic Monitor
-
Fast Shipping
Original industrial automation parts available for prompt shipment worldwide.
-
Easy Returns
30-day return support with a 12-month warranty for reliable after-sales protection.
-
24/7 support
Responsive professional support to help maintain stable and efficient operations.
-
Genuine & Original
100% authentic, sourced directly from trusted industrial automation manufacturers.
Technical & Buying Guide
-
What Makes Emerson DeltaV M-Series Ideal for Oil & Gas DCS Control?
Emerson's DeltaV M-Series controller delivers reliable regulatory control for oil and gas assets through MQ and MX va...
-
What Makes Siemens PCS 7 AS410 Ideal for Chemical DCS?
Siemens PCS 7 with the AS410 automation station delivers high availability for continuous chemical manufacturing. Thi...
-
What Causes Most ABB AC800M Migration Failures?
ABB AC800M controllers have run for 12 to 18 years in many plants, and spare part lead times now reach 16 weeks. This...
-
How to Migrate Honeywell TDC3000 to Experion PKS?
This guide explains how process plants can migrate aging Honeywell TDC3000 DCS systems to Experion PKS C300 through p...
-
What Makes PLC and DCS Migration Projects Succeed?
Multi-vendor control system migration demands disciplined project management, early interface testing, and structured...
-
How Does GE OPC UA Server Connect Mixed PLC and DCS Systems?
GE OPC UA server helps industrial plants unify fragmented PLC and DCS data through a vendor-neutral standard, coverin...