Transform your home with the latest multi-electronics solutions, from intelligent lighting to vOptimize your operations with the Bently Nevada 3500 Monitoring System, offering real-time vibration and machinery condition monitoring to prevent failures and maximize uptime.oice-controlled devices all designed to make life easier, safer, and more connected.
SKU:1762-L24AWA
1762-L24AWA Allen-Bradley MicroLogix 1200 Controller
Manufacturer: Allen-Bradley
Product No.: 1762-L24AWA
Product Type: Controller Module
Product Origin: USA
Payment:T/T, Western Union
Weight: 900g
Shipping port: Xiamen
Warranty: 12 months
Share
- Fast Delivery
- 24/7 Support
- Quality Assurance
Description
Allen-Bradley 1762-L24AWA MicroLogix 1200 PLC
Allen-Bradley 1762-L24AWA | MicroLogix 1200 Programmable Logic Controller with 14 AC inputs and 10 relay outputs. Embedded 8-pin mini-DIN communication port supports DF1, DH-485, ASCII, and Modbus protocols. Powered by external 120/240VAC nominal supply. Weight: approximately 0.9 kg (2.0 lbs).
Key Features
14 digital inputs (120VAC). 10 relay outputs. 8-pin mini-DIN serial port. DF1, DH-485, ASCII, and Modbus protocol support. 120/240VAC input power. 47-63 Hz operating frequency. 68 VA power supply usage. 20 million mechanical cycles relay life. ON/OFF response time 10ms. UL, c-UL, and CE certified.
Technical Specifications
| Manufacturer | Rockwell Automation |
| Brand | Allen-Bradley |
| Part Number | 1762-L24AWA |
| Product Line | MicroLogix 1200 |
| Module Type | Programmable Controller |
| Input Power | 120-240V AC |
| No. of Inputs | 14 (120V AC) |
| No. of Outputs | 10 (Relay) |
| Input Circuit Type | 120V AC |
| Output Circuit Type | Relay |
| Relay Contact Rating | 24-125VDC; 120-240VAC |
| Load Current | 10A minimum per point |
| Mechanical Cycles | 20,000,000 |
| Communication Ports | 1 x 8-pin mini-DIN serial |
| Supported Protocols | DF1, DH-485, ASCII, Modbus |
| Operating Frequency | 47 to 63 Hz |
| On-State Current | 12 mA |
| Inrush Current (Max) | 250 mA |
| Power Supply Usage | 68 VA |
| Inrush Current (120V) | 25A for 8 ms |
| Inrush Current (240V) | 40A for 4 ms |
| Dimensions (H x W x D) | 90 x 160 x 87 mm (104 mm with DIN latch open) |
| Weight | 0.9 kg (2.0 lbs) |
| Operating Temperature | 0°C to +55°C (32°F to 131°F) |
| Storage Temperature | -40°C to +85°C (-40°F to 185°F) |
| Relative Humidity | 5-95% (non-condensing) |
| Vibration Resistance | 1.5G @ 10-500 Hz |
| Shock Resistance | 15G operational |
| Certifications | UL, c-UL, CE |
| UPC | 10612598207173 |
Installation Notes
Mount horizontally in a clean, dry environment. Connect 100-240VAC supply at 47-63 Hz. Use 8-pin mini-DIN port for programming and network communication. Observe overvoltage category II limits. Maintain 0°C to 55°C operating temperature. Ensure adequate ventilation for heat dissipation.
Engineering Advantages
All-in-one controller with integrated power supply reduces panel space. 14 AC inputs simplify direct connection to field devices without interposing relays. 10 relay outputs handle both AC and DC loads. Multiple protocol support (DF1, DH-485, ASCII, Modbus) enables flexible integration. 20 million cycle relay life ensures long-term reliability.
FAQs
Q1: How many inputs and outputs does this controller have?
A1: 14 digital inputs (120VAC) and 10 relay outputs.
Q2: What communication protocols are supported?
A2: DF1, DH-485, ASCII, and Modbus via the 8-pin mini-DIN port.
Q3: What is the power supply requirement?
A3: 120/240VAC nominal at 47-63 Hz, 68 VA maximum.
Additional Specifications
Scalar (V/f)
Vector
AC-powered
Buying Guide
- Confirm the exact model, part number, and specifications before ordering.
- Ensure compatibility with your current machinery or control systems.
- Reach out via sale@etowonauto.com or +8617859788089 for technical assistance.
- Review delivery options, lead times, and shipping requirements.
- Follow manufacturer instructions and best practices during installation.
Shipping And Return
In-stock items are typically dispatched the same business day. For products not currently in stock, dispatch times may vary based on availability. International shipping is available, and shipping costs are calculated according to destination, weight, and carrier selection.
Returns are accepted within 30 days of receipt, provided items are unused and in original condition. Return shipping costs are the responsibility of the customer. Please contact us before returning any item to receive return authorization.
For more details, please review our Shipping & Return Policy.

3500/61-05-CN Temperature Monitor Module | Bently Nevada
3500/22-01-02-CN TDI Module Bently Nevada
Bently Nevada 3500/42-04-00 | Seismic Monitor
-
Fast Shipping
Original industrial automation parts available for prompt shipment worldwide.
-
Easy Returns
30-day return support with a 12-month warranty for reliable after-sales protection.
-
24/7 support
Responsive professional support to help maintain stable and efficient operations.
-
Genuine & Original
100% authentic, sourced directly from trusted industrial automation manufacturers.
Technical & Buying Guide
-
What Causes Most ABB AC800M Migration Failures?
ABB AC800M controllers have run for 12 to 18 years in many plants, and spare part lead times now reach 16 weeks. This...
-
How to Migrate Honeywell TDC3000 to Experion PKS?
This guide explains how process plants can migrate aging Honeywell TDC3000 DCS systems to Experion PKS C300 through p...
-
What Makes PLC and DCS Migration Projects Succeed?
Multi-vendor control system migration demands disciplined project management, early interface testing, and structured...
-
How Does GE OPC UA Server Connect Mixed PLC and DCS Systems?
GE OPC UA server helps industrial plants unify fragmented PLC and DCS data through a vendor-neutral standard, coverin...
-
How Does Modular Gas Transmitter Cut Maintenance Costs?
The Honeywell Universal Transmitter offers a modular, multi-sensor platform for gas monitoring in hazardous industria...
-
Why Do Bently Nevada TSI Sensors Need Single-Point Grounding?
Poor grounding in Bently Nevada TSI systems creates millivolt-level noise that masks real vibration signals and trigg...