Transform your home with the latest multi-electronics solutions, from intelligent lighting to vOptimize your operations with the Bently Nevada 3500 Monitoring System, offering real-time vibration and machinery condition monitoring to prevent failures and maximize uptime.oice-controlled devices all designed to make life easier, safer, and more connected.
SKU:1756-IA16I
1756-IA16I Allen-Bradley Isolated Module
Manufacturer: Allen-Bradley
Product No.: 1756-IA16I
Product Type: AC Input Module
Product Origin: USA
Payment:T/T, Western Union
Weight: 200g
Shipping port: Xiamen
Warranty: 12 months
Share
- Fast Delivery
- 24/7 Support
- Quality Assurance
Description
Allen-Bradley ControlLogix 1756-IA16I Isolated AC Input Module
The 1756-IA16I is a 16-channel isolated AC input module from the Allen-Bradley ControlLogix series. Rockwell Automation designed this module with 1500V AC isolation between channels to eliminate ground loop issues. It works with 120V AC signals and provides reliable detection in industrial environments.
Key Features
- 16 isolated AC input channels for industrial control systems
- 1500V AC isolation between channels eliminates ground loops
- Works with 120V AC signals (79-132V AC range)
- Programmable response time from 9-18 ms
- Easy installation in any ControlLogix chassis slot
- Front LED indicators for per-channel status
Technical Specifications
- Brand: Allen-Bradley / Rockwell Automation
- Series: ControlLogix
- Model: 1756-IA16I
- Type: 16-channel isolated AC input module
- Input Voltage Range: 79-132V AC
- Frequency Range: 47-63 Hz
- On-State Current: 5-15 mA
- Response Time: 9-18 ms programmable
- Power Consumption: 4.9W max
- Operating Temperature: 0-60°C
- Isolation: 1500V AC between channels
Module Variants
- 1756-IA16I/A - Standard version
- 1756-IA16I/B - Extended temperature range
- 1756-IA16I/C - High-density version
Installation Guide
- Fits any ControlLogix chassis slot
- Requires 1756-TBCH terminal block
- Tool-free installation for quick mounting
- Front LED indicators for status monitoring
Compatibility
- Works with all ControlLogix processors
- Compatible with Studio 5000 software
- Supports remote I/O configurations
Industrial Applications
- Motor status monitoring
- Conveyor belt controls
- Pump system diagnostics
- HVAC equipment monitoring
- Lighting control systems
Problem Solving
- Eliminates ground loop issues with isolated inputs
- Reduces wiring complexity in high-voltage systems
- Provides reliable AC signal detection
- Prevents false triggers from electrical noise
Package Includes
- 1x Allen-Bradley 1756-IA16I isolated AC input module
- 1x installation guide
- 1x mounting screws
- 1x front label sheet
Shipping Information
- FedEx 2-day delivery available
- UPS ground shipping option
- DHL express international
- Same day dispatch for orders before 3PM
Technical Documentation
📥 Download Product Datasheet PDF
FAQ
1. What is the isolation rating for the 1756-IA16I?
The module provides 1500V AC isolation between channels, eliminating ground loop issues.
2. What terminal block does this module require?
The 1756-IA16I requires the 1756-TBCH terminal block for wiring connections.
3. What is the programmable response time range?
The response time is 9-18 ms programmable via Studio 5000 software.
Additional Specifications
- Black
Scalar (V/f)
Vector
AC-powered
Buying Guide
- Confirm the exact model, part number, and specifications before ordering.
- Ensure compatibility with your current machinery or control systems.
- Reach out via sale@etowonauto.com or +8617859788089 for technical assistance.
- Review delivery options, lead times, and shipping requirements.
- Follow manufacturer instructions and best practices during installation.
Shipping And Return
In-stock items are typically dispatched the same business day. For products not currently in stock, dispatch times may vary based on availability. International shipping is available, and shipping costs are calculated according to destination, weight, and carrier selection.
Returns are accepted within 30 days of receipt, provided items are unused and in original condition. Return shipping costs are the responsibility of the customer. Please contact us before returning any item to receive return authorization.
For more details, please review our Shipping & Return Policy.

3500/61-05-CN Temperature Monitor Module | Bently Nevada
3500/22-01-02-CN TDI Module Bently Nevada
Bently Nevada 3500/42-04-00 | Seismic Monitor
-
Fast Shipping
Original industrial automation parts available for prompt shipment worldwide.
-
Easy Returns
30-day return support with a 12-month warranty for reliable after-sales protection.
-
24/7 support
Responsive professional support to help maintain stable and efficient operations.
-
Genuine & Original
100% authentic, sourced directly from trusted industrial automation manufacturers.
Technical & Buying Guide
-
How does off-site monitoring cut fault diagnosis time by 79%?
This article examines how GE long-distance data transmission enables off-site centralized monitoring for geographi...
-
How Do Bently Nevada Transmitters Improve Bearing Health Monitoring?
This technical article examines the role of Bently Nevada vibration transmitters in industrial automation for ea...
-
What Are the Real ROI Gains of Upgrading Legacy Turbine Monitoring?
Operating legacy turbine supervisory instrumentation (TSI) beyond 12 years exposes power stations to false trips, pro...
-
How Does 3500/22M Improve Mixed-Vendor Safety Integration?
This article examines the measurable performance gap between Bently Nevada's legacy 3500/22 and the upgraded 3500/22M...
-
Fixed Gas Detector or Transmitter: Which Fits Your Plant?
This article examines the practical differences between fixed gas detectors and gas detection transmitters in industr...
-
How to Achieve Deterministic Multi-Unit Coordination in GE Systems?
This article examines real-world communication bottlenecks in multi-unit industrial facilities using GE control syste...