Transform your home with the latest multi-electronics solutions, from intelligent lighting to vOptimize your operations with the Bently Nevada 3500 Monitoring System, offering real-time vibration and machinery condition monitoring to prevent failures and maximize uptime.oice-controlled devices all designed to make life easier, safer, and more connected.
SKU:140XTS33200
140XTS33200 Schneider Electric Modicon Quantum 40-Pin Connector
Manufacturer: Schneider
Product No.: 140XTS33200
Product Type: I/O Connector
Product Origin: FR
Payment:T/T, Western Union
Weight: 150g
Shipping port: Xiamen
Warranty: 12 months
Share
- Fast Delivery
- 24/7 Support
- Quality Assurance
Description
Product Overview
The Schneider Electric 140XTS33200 is a specialized 40-pin input/output connector designed for the Modicon Quantum automation platform. Recognized by its distinct blue color code, this connector is specifically engineered for use with intrinsically safe I/O modules. Weighing only 0.15 kg (0.33 lbs), it provides a secure and organized termination point for 8-channel signal wiring in hazardous or sensitive industrial environments.
Design for Safety and Precision
Intrinsically Safe Configuration
As part of the Modicon Quantum connection accessories, the 140XTS33200 is built to meet stringent safety standards. Its blue terminal strip clearly identifies it for intrinsically safe applications, preventing cross-connection with standard modules. Despite its lightweight 0.15 kg design, it supports full galvanic isolation between channels, effectively eliminating electrical interference and enhancing overall signal integrity across its 8-channel capacity.
Broad Module Compatibility
This 40-pin connector is a versatile component within the Quantum series, offering seamless integration with several high-density modules. It is fully compatible with the 140AII33000, 140DII33000, 140DIO33000, 140AII33010, and 140AIO33000. The 0.15 kg unit features an IP20 protection rating, ensuring reliable performance in controlled industrial cabinets used for HVAC, automotive testing, and power generation.
Technical Specifications
| Feature | Specification |
|---|---|
| Manufacturer | Schneider Electric |
| Product Line | Modicon Quantum |
| Part Number | 140XTS33200 |
| Pin Count | 40 Pins |
| Color Code | Blue (Intrinsically Safe) |
| Isolation Type | Galvanic (Channel-to-Channel) |
| Net Weight | 0.15 kg (0.33 lbs) |
Industrial Applications
The 140XTS33200 is widely utilized in sectors requiring precise control and high safety margins. It is frequently found in HVAC systems, boiler and furnace control, food processing equipment, and automotive test stands. Its 40-pin high-density layout allows for efficient wiring of multiple I/O points while maintaining a small footprint. The 0.15 kg connector is designed for quick attachment to the front of Quantum modules, reducing downtime during installation or maintenance.
Reliability and Identification
Identification is simplified through the blue color-coding of the terminal strip, which is an industry-standard indicator for intrinsic safety. This ensures that field technicians can quickly verify the wiring type at a glance. The 140XTS33200 provides an IP20-rated enclosure for the wire terminations, ensuring the 0.15 kg assembly remains protected from accidental contact within the control panel while facilitating easy access for testing.
Technical FAQs
Q1: Why is this connector blue?
A1: The blue color indicates that the connector is intended for "Intrinsically Safe" wiring, distinguishing it from standard black or grey connectors to prevent wiring errors in hazardous areas.
Q2: Does this connector come with a cable?
A2: The 140XTS33200 is a terminal block connector designed for direct field wiring. Cables are typically purchased separately based on the specific I/O module being used.
Q3: Is the 0.15 kg weight specific to this 40-pin model?
A3: Yes, the 0.15 kg refers to the net weight of the 40-pin blue terminal assembly. It is lightweight to minimize stress on the module's front connector interface.
Additional Specifications
- Gray
- Black
- White
Scalar (V/f)
Vector
AC-powered
Buying Guide
- Confirm the exact model, part number, and specifications before ordering.
- Ensure compatibility with your current machinery or control systems.
- Reach out via sale@etowonauto.com or +8617859788089 for technical assistance.
- Review delivery options, lead times, and shipping requirements.
- Follow manufacturer instructions and best practices during installation.
Shipping And Return
In-stock items are typically dispatched the same business day. For products not currently in stock, dispatch times may vary based on availability. International shipping is available, and shipping costs are calculated according to destination, weight, and carrier selection.
Returns are accepted within 30 days of receipt, provided items are unused and in original condition. Return shipping costs are the responsibility of the customer. Please contact us before returning any item to receive return authorization.
For more details, please review our Shipping & Return Policy.

3500/61-05-CN Temperature Monitor Module | Bently Nevada
3500/22-01-02-CN TDI Module Bently Nevada
Bently Nevada 3500/42-04-00 | Seismic Monitor
-
Fast Shipping
Original industrial automation parts available for prompt shipment worldwide.
-
Easy Returns
30-day return support with a 12-month warranty for reliable after-sales protection.
-
24/7 support
Responsive professional support to help maintain stable and efficient operations.
-
Genuine & Original
100% authentic, sourced directly from trusted industrial automation manufacturers.
Technical & Buying Guide
-
Can a Multi-Vendor PM Checklist Cut PLC Downtime?
This article presents a standardized annual preventive maintenance checklist for mixed-vendor industrial control envi...
-
Why Emerson Hot Redundancy Retrofit Slashes Downtime by 96%?
Process plants relying on GE Fanuc single PLCs face 47% of unplanned outages from controller failure, costing $38,000...
-
Cut Migration Engineering Hours by 60% – How Does It Work?
This technical guide examines the operational risks and engineering overhead of maintaining separate GE Proficy HMI a...
-
Is Your 1756 Supply Chain Risking Production?
Counterfeit 1756 modules cause 68% of unplanned PLC downtime. This guide covers a four-step verification method, real...
-
Why Do 72% of Analog Loop Failures Trace Back to Wiring Errors?
This technical guide presents field-verified wiring protocols for integrating Emerson Rosemount 4–20mA HART transmitt...
-
GE Fanuc VersaMax: Did It Replace Obsolete ABB AC500-ECO?
This technical case study details a complete control system retrofit for a 1200m³/day municipal water plant. Our team...
