Transform your home with the latest multi-electronics solutions, from intelligent lighting to vOptimize your operations with the Bently Nevada 3500 Monitoring System, offering real-time vibration and machinery condition monitoring to prevent failures and maximize uptime.oice-controlled devices all designed to make life easier, safer, and more connected.
SKU:140NOM25200
140NOM25200 Quantum Modbus Plus Fiber Schneider
Manufacturer: Schneider
Product No.: 140NOM25200
Product Type: Adaptor Module
Product Origin: FR
Payment:T/T, Western Union
Weight: 494g
Shipping port: Xiamen
Warranty: 12 months
Share
- Fast Delivery
- 24/7 Support
- Quality Assurance
Description
Schneider Electric Modicon Quantum 140NOM25200 DIO Head-End Adaptor with Modbus Plus Fiber Optic
The 140NOM25200 is a DIO (Distributed I/O) head-end adaptor from the Schneider Electric Modicon Quantum automation platform featuring 1 Modbus Plus fiber optic port (single copper) and 1 Modbus RS232 twisted pair port.
Key Features
- DIO head-end adaptor for Modicon Quantum systems
- 1 Modbus Plus fiber optic port (single copper) with TX/RX connectors
- 1 Modbus RS232 twisted pair port (RJ45 connector)
- Transmission rate: 1 Mbit/s
- Wavelength: 820 nm (0.000032284 in)
- I/O words capacity: 30 input / 32 output words
- Built-in diagnostics: processor, checksum, RAM address, RAM checks
- Power dissipation: 4 W
- Bus current requirement: 750 mA
- Marine certified: DNV, GL, RINA, RMRS
- CSA Class 1 Division 2 hazardous location certified
Technical Specifications
- Brand: Schneider Electric
- Series: Modicon Quantum
- Model: 140NOM25200
- Product Type: DIO Head-End Adaptor
- Number of Ports: 2
- Port Configuration:
- 1 x Modbus Plus fiber optic (single copper, 2 TX/RX connectors)
- 1 x Modbus RS232 twisted pair (RJ45 connector)
- Transmission Rate: 1 Mbit/s
- I/O Words: 30 input / 32 output words
- Power Dissipation: 4 W
- Bus Current Requirement: 750 mA
- Module Format: Standard
Fiber Optic Specifications
- Wavelength: 820 nm
- Minimum Pulse Width Distortion/Jitter: 5 ns
- Rise/Fall Time: 20 ns
- Dynamic Range: 20 dB
- Detected Silence: -36 dBm
- Sensitivity Scale: > 30 dBm
Power Loss Budget by Fiber Type
- 62.5/125 µm: 11 dB
- 100/140 µm: 16.5 dB
- 50/125 µm: 6.5 dB
Optical Transmission Power
- 100/140 µm: -16 to -9 dBm
- 50/125 µm: -19.8 to -12.8 dBm
- 62.5/125 µm: -3.5 to -110.5 dBm
Environmental Specifications
- Operating Temperature: 0 to 60°C (32 to 140°F)
- Storage Temperature: -40 to 85°C (-40 to 185°F)
- Relative Humidity: 95% without condensation
- Operating Altitude: ≤ 5000 m (16404 ft)
- Resistance to Electrostatic Discharge: 4 kV contact, 8 kV air (IEC 801-2)
- Resistance to Electromagnetic Fields: 9.1 V/m (10 V/m) 80-2000 MHz (IEC 801-3)
Package Details
- Package Dimensions:
- Height: 5.0 cm (1.97 in)
- Width: 16.5 cm (6.50 in)
- Length: 31.0 cm (12.20 in)
- Package Weight: 494.0 g (17.4 oz)
- Package Volume: 2,557.5 cm³ (5.0 × 16.5 × 31.0 cm)
- Unit Type: PCE (Piece)
- Units per Package: 1
FAQ
Q1: What is the part number for this fiber optic DIO adaptor?
The part number is 140NOM25200.
Q2: What communication ports does the 140NOM25200 feature?
It features 1 Modbus Plus fiber optic port (with TX/RX connectors) and 1 Modbus RS232 twisted pair port (RJ45).
Q3: What are the fiber optic specifications and certifications?
It operates at 820 nm wavelength with 5 ns jitter and supports multiple fiber types. It carries DNV, GL, RINA, RMRS marine certifications and CSA Class 1 Division 2.
Additional Specifications
- Gray
- Black
- White
- Beige
Scalar (V/f)
Vector
AC-powered
Buying Guide
- Confirm the exact model, part number, and specifications before ordering.
- Ensure compatibility with your current machinery or control systems.
- Reach out via sale@etowonauto.com or +8617859788089 for technical assistance.
- Review delivery options, lead times, and shipping requirements.
- Follow manufacturer instructions and best practices during installation.
Shipping And Return
In-stock items are typically dispatched the same business day. For products not currently in stock, dispatch times may vary based on availability. International shipping is available, and shipping costs are calculated according to destination, weight, and carrier selection.
Returns are accepted within 30 days of receipt, provided items are unused and in original condition. Return shipping costs are the responsibility of the customer. Please contact us before returning any item to receive return authorization.
For more details, please review our Shipping & Return Policy.

3500/61-05-CN Temperature Monitor Module | Bently Nevada
3500/22-01-02-CN TDI Module Bently Nevada
Bently Nevada 3500/42-04-00 | Seismic Monitor
-
Fast Shipping
Original industrial automation parts available for prompt shipment worldwide.
-
Easy Returns
30-day return support with a 12-month warranty for reliable after-sales protection.
-
24/7 support
Responsive professional support to help maintain stable and efficient operations.
-
Genuine & Original
100% authentic, sourced directly from trusted industrial automation manufacturers.
Technical & Buying Guide
-
How Can Modern Automation Reduce Power Plant Downtime?
Discover power plant control system upgrade strategies using PLC & DCS. Real case studies, 24/7 support, and expe...
-
How to Extend DCS and PLC Lifespan With Smart Maintenance?
Effective maintenance of DCS and PLC systems is essential for maximizing uptime and efficiency in industrial automati...
-
Why Combine DCS with Edge Controllers in Oil & Gas?
Expert guide on selecting and maintaining PLC and DCS systems for oil & gas automation. Covers environmental fact...
-
How Does PLC-DCS Integration Boost Power Plant Efficiency?
This article explores strategic approaches to integrating PLC and DCS systems in power plants, featuring real-world c...
-
Are Legacy PLCs Putting Your Petrochemical Operations at Risk?
This article explores the critical role of troubleshooting and optimization in maintaining PLC and DCS reliability wi...
-
What Causes DCS Failures in Power Plants and How to Fix Them?
This article provides a comprehensive guide to managing Distributed Control System (DCS) failures in power generation...