Transform your home with the latest multi-electronics solutions, from intelligent lighting to vOptimize your operations with the Bently Nevada 3500 Monitoring System, offering real-time vibration and machinery condition monitoring to prevent failures and maximize uptime.oice-controlled devices all designed to make life easier, safer, and more connected.
SKU:140DDI35310C
140DDI35310C 24V DC Discrete Input Module Schneider
Manufacturer: Schneider
Product No.: 140DDI35310C
Product Type: Input Module
Product Origin: FR
Payment:T/T, Western Union
Weight: 300g
Shipping port: Xiamen
Warranty: 12 months
Share
- Fast Delivery
- 24/7 Support
- Quality Assurance
Description
Overview
The Schneider Electric 140DDI35310C is a discrete input module for Modicon Quantum systems. It provides 32 sink inputs with 24V DC negative logic.
Key Specifications
- Manufacturer: Schneider Electric – Modicon Quantum series
- Model: 140DDI35310C – Discrete input module
- Channels: 32 inputs, negative logic (sink)
- Input Voltage: 24V DC (19.2-30V range)
- Response Time: ≤1ms ON to OFF, ≤1ms OFF to ON
- Impedance: 2400 Ohm per channel
Input Groups
- 32 channels split into 4 groups of 8 inputs.
- State 1 guaranteed: -30 to -15V DC at ≥2.5mA.
- State 0 guaranteed: -5 to 0V DC at ≤0.5mA.
- Requires 2 input words for addressing.
Protection
- Input protection by resistor limiting current.
- Withstands 30V continuous, 50V for 1ms pulse.
- Max leakage current: 200mA at 5.5V.
- Power dissipation: 1.5W + (0.26 × active channels).
Isolation
- Group-to-bus isolation: 1780Vrms for 1 minute.
- Inter-group isolation: 500Vrms for 1 minute.
- Bus current requirement: 330mA.
- Standard format fits Quantum backplanes.
Package & Shipping
- Dimensions: 16.3 × 4.5 × 31.2 cm, net weight 0.3 kg.
- Includes: One 140DDI35310C module with documentation.
- Shipping: Fast delivery via FedEx, UPS, or DHL.
FAQ
Q: What is negative logic sink input?
A: The module reads signals referenced to ground. Current sinks from input to common when activated.
Q: How does 140DDI35310C differ from 140DDI35300C?
A: 140DDI35310C uses negative logic. 140DDI35300C uses positive logic. Choose based on your field device wiring.
Q: What is the maximum input voltage?
A: Continuous input is 30V DC. The module survives 50V for 1ms decaying pulses without damage.
Additional Specifications
- Gray
- Black
- White
Scalar (V/f)
Vector
AC-powered
Buying Guide
- Confirm the exact model, part number, and specifications before ordering.
- Ensure compatibility with your current machinery or control systems.
- Reach out via sale@etowonauto.com or +8617859788089 for technical assistance.
- Review delivery options, lead times, and shipping requirements.
- Follow manufacturer instructions and best practices during installation.
Shipping And Return
In-stock items are typically dispatched the same business day. For products not currently in stock, dispatch times may vary based on availability. International shipping is available, and shipping costs are calculated according to destination, weight, and carrier selection.
Returns are accepted within 30 days of receipt, provided items are unused and in original condition. Return shipping costs are the responsibility of the customer. Please contact us before returning any item to receive return authorization.
For more details, please review our Shipping & Return Policy.

3500/61-05-CN Temperature Monitor Module | Bently Nevada
3500/22-01-02-CN TDI Module Bently Nevada
Bently Nevada 3500/42-04-00 | Seismic Monitor
-
Fast Shipping
Original industrial automation parts available for prompt shipment worldwide.
-
Easy Returns
30-day return support with a 12-month warranty for reliable after-sales protection.
-
24/7 support
Responsive professional support to help maintain stable and efficient operations.
-
Genuine & Original
100% authentic, sourced directly from trusted industrial automation manufacturers.
Technical & Buying Guide
-
Why Do 42% of Offshore DCS Downtime Events Trace to Power Modules?
This technical analysis examines the root causes of Allen‑Bradley power module failures in offshore control cabi...
-
Can Layered PLC Fix Chemical Batch Failures?
This technical article presents field-validated ABB AC800M configuration strategies for high-stability fine chemical ...
-
How to Select GE Fanuc 90-30 Spare Parts for Hot Rolling Mills?
This article provides a technical guide for selecting and managing GE Fanuc Series 90-30 PLC spare parts in meta...
-
How Does Bently Nevada 3500 Reduce Unplanned Turbine Trips?
This technical article analyzes the quantitative value of the Bently Nevada 3500 TSI system in thermal power shaft pr...
-
Dual Compliance Standards for Pharma Automation?
This article presents a quantified engineering methodology for explosion-proof PLC and DCS system design in GMP-certi...
-
How to Avoid Bulk Sourcing Risks for Power Plant Control Spares?
This guide presents field-validated strategies for bulk sourcing industrial control spares in power plants. It q...