Transformeer je huis met de nieuwste multi-elektronica oplossingen, van intelligente verlichting tot spraakgestuurde apparaten, allemaal ontworpen om het leven gemakkelijker, veiliger en meer verbonden te maken.
SKU:V18345-2010421001
V18345-2010421001 | ABB TZIDC Positioner Analog Feedback
Manufacturer: ABB
Product No.: V18345-2010421001
Product Type: Valve Positioner Module
Product Origin: Sweden
Payment:T/T, Western Union
Weight: 1700g
Shipping port: Xiamen
Warranty: 12 months
Delen
- Snelle levering
- 24/7 Ondersteuning
- Kwaliteitsborging
Beschrijving
Product Overview
The V18345-2010421001 is a TZIDC electro-pneumatic positioner from ABB, designed for precise valve control on linear and rotary actuators. Features 4–20 mA two-wire input, HART communication, double-acting fail-safe output, and plug-in analog position feedback (4–20 mA). Aluminum IP65/NEMA 4X housing. Weight: 1.7 kg.
Analog Position Feedback Module
Range 4–20 mA with configurable split ranges. Two-wire circuitry, power supply 24 V DC (10–30 V DC) or 48 V DC (20–48 V DC, no explosion protection). Action direct or reverse (configurable). Characteristic deviation <1%. Without a signal from the positioner, the module sets output to >20 mA (alarm level).
Technical Specifications
| Parameter | Specification |
|---|---|
| Part Number | V18345-2010421001 |
| Manufacturer | ABB |
| Type | TZIDC Electro-Pneumatic Positioner |
| Input Signal | 4–20 mA (two-wire) |
| Communication | HART, LKS local connector |
| Output / Safe Position | Double acting, fail safe |
| Analog Position Feedback | 4–20 mA, configurable split ranges |
| Feedback Power Supply | 24 V DC (10–30 V DC) / 48 V DC (20–48 V DC, non-Ex) |
| Feedback Deviation | <1% |
| Supply Pressure | 1.4–6 bar (20–90 psi) |
| Air Consumption | <0.03 kg/h / 0.015 scfm |
| Housing Material | Aluminum, varnished, RAL 9005 |
| Protection Class | IP65 / NEMA 4X |
| Pneumatic Connections | G 1/4 or 1/4-18 NPT |
| Electrical Connections | Cable: 1/2-14 NPT; Air pipe: 1/4-18 NPT |
| Digital Input | 0–5 V DC (logical 0), 11–30 V DC (logical 1) |
| Digital Output | 5–11 V DC (NAMUR DIN 19234) |
| Weight | 1.7 kg |
Installation & Maintenance
Mounting
Mount to linear actuators per DIN/IEC 534/NAMUR or rotary actuators per VDI/VDE 3845. Mechanical position indicator provides visual feedback. Mounting orientation has no measurable influence on performance.
Air Supply
Use instrument air free of oil, water, and dust. Supply pressure 1.4–6 bar (20–90 psi). Do not exceed actuator max operating pressure. Air consumption <0.03 kg/h independent of supply pressure.
Electrical Connection
Connect 4–20 mA two-wire signal. HART communication via 20 mA signal line. Analog position feedback module provides 4–20 mA output proportional to valve position. Cable entry: 1/2-14 NPT.
Engineering Advantages
Double-Acting Fail-Safe
Fail-safe output moves actuator to safe position on electrical power failure. For double-acting actuators, output 1 is depressurized and output 2 is pressurized, ensuring reliable safety operation.
Integrated Analog Feedback
Plug-in analog position feedback module (4–20 mA) provides accurate valve position indication. Configurable split ranges and direct/reverse action. Outputs >20 mA alarm level when no positioner signal is present.
Robust Environmental Protection
IP65/NEMA 4X aluminum housing with electrostatic epoxy varnish resists corrosion and dust. Mechanical position indicator and HART communication enable easy commissioning and remote diagnostics.
Technical FAQs
Q1: What is the fail-safe behavior on electrical power failure?
A1: Double-acting fail-safe. Output 1 is depressurized and the valve moves to its safe position. The second output is additionally pressurized.
Q2: Does this model include analog position feedback?
A2: Yes. The plug-in analog position feedback module provides 4–20 mA output with configurable split ranges and <1% deviation.
Q3: What supply pressure range does this positioner require?
A3: 1.4–6 bar (20–90 psi). Do not exceed the maximum operating pressure of the actuator.
Aanvullende specificaties
- Zilver
Scalar (V/f)
Vector
Op netstroom
Koopgids
- Bevestig het exacte model, onderdeelnummer en specificaties voordat u bestelt.
- Zorg voor compatibiliteit met uw huidige machines of besturingssystemen.
- Neem contact op via sale@etowonauto.com of +8617859788089 voor technische ondersteuning.
- Bekijk de leveringsopties, doorlooptijden en verzendvereisten.
- Volg de instructies van de fabrikant en de beste praktijken tijdens de installatie.
Verzending en Retourneren
Voorraadartikelen worden doorgaans dezelfde werkdag verzonden. Voor producten die momenteel niet op voorraad zijn, kunnen de verzendtijden variëren afhankelijk van de beschikbaarheid. Internationale verzending is mogelijk, en de verzendkosten worden berekend op basis van bestemming, gewicht en gekozen vervoerder.
Retourzendingen worden geaccepteerd binnen 30 dagen na ontvangst, mits de artikelen ongebruikt en in originele staat zijn. De kosten voor retourzending zijn voor rekening van de klant. Neem alstublieft contact met ons op voordat u een artikel retourneert om een retourautorisatie te ontvangen.
Voor meer details kunt u onze Verzend- en Retourbeleid raadplegen.

3500/61-05-CN Temperature Monitor Module | Bently Nevada
3500/22-01-02-CN TDI Module Bently Nevada
Bently Nevada 3500/42-04-00 | Seismic Monitor
-
Snelle verzending
Originele onderdelen voor industriële automatisering beschikbaar voor snelle verzending wereldwijd.
-
Eenvoudige Retourzendingen
30 dagen retourrecht met 12 maanden garantie voor betrouwbare nazorgbescherming.
-
24/7 ondersteuning
Responsieve professionele ondersteuning om stabiele en efficiënte bedrijfsvoering te behouden.
-
Echt & Origineel
100% authentiek, rechtstreeks afkomstig van vertrouwde fabrikanten van industriële automatisering.
Technische & Koopgids
-
How Can You Prevent Historian Data Loss During Experion PKS Migration?
This article presents a measurable playbook for protecting Honeywell Experion historian data during server and H...
-
How Do MTL Barriers and DCS IO Cards Affect Loop Voltage?
Intrinsic safety circuits protect hazardous process areas, yet loop impedance budgeting often receives far less atten...
-
How Can You Tune GE RX3i and RX7i Ethernet for Heavy Industry?
Intermittent Ethernet timeouts on GE RX3i and RX7i controllers are among the hardest faults in heavy process plants, ...
-
Why Does FCS Redundancy Not Protect Your HIS Configuration?
This article examines the operational risks of Yokogawa CENTUM VP HIS lockups and explains why FCS controller re...
-
How Does 1756 Analog I/O Calibration Drift Affect PLC Accuracy?
This article examines calibration drift in Allen-Bradley ControlLogix 1756 analog I/O modules, presenting quanti...
-
Why Do 31% of ABB 800xA S800 IO Hot Swaps Fail in DCS Systems?
ABB 800xA S800 hot swap failures rarely stem from defective hardware. Field data from 142 card replacement jobs shows...