SKU:TSXDMZ28AR
TSXDMZ28AR Schneider Electric 28 Point Relay Discrete Base
Manufacturer: Schneider
Product No.: TSXDMZ28AR
Product Type: I/O Base
Product Origin: FR
Payment:T/T, Western Union
Weight: 500g
Shipping port: Xiamen
Warranty: 12 months
Delen
- Snelle levering
- 24/7 Ondersteuning
- Kwaliteitsborging
Beschrijving
Product Overview
The TSXDMZ28AR is a discrete relay I/O base module engineered by Schneider Electric for the Modicon TSX Micro automation platform. Designed for industrial process control, this module integrates 28 total channels comprising 16 AC discrete inputs (100–120 V AC) and 12 Normally Open (NO) relay outputs. Equipped with screw terminal blocks and certified to IEC 1131-2 Type 2 standards, the TSXDMZ28AR provides high isolation between field circuits and logic controls. Weighing 0.5 kg (1.1 lb) in a compact housing, it mounts directly onto standard DIN rails in control cabinets.
Core Technical Advantages
- Combined High-Density I/O: Integrates 16 AC inputs and 12 relay outputs into a single Modicon TSX Micro slot base.
- Versatile Relay Output Ratings: Supports switching loads up to 264 V AC and 34 V DC with a 3 A conventional thermal current (Ith).
- Rugged Electrical Isolation: Provides 1500 V isolation for 1 second with an insulation resistance of ≥ 10 MΩ.
Technical Specifications
| Parameter | Specification Details |
|---|---|
| Brand & Manufacturer | Schneider Electric |
| Product Line Family | Modicon TSX Micro Automation Platform |
| Model Part Number | TSXDMZ28AR |
| EAN Code | 3389110540444 |
| Product Function Type | Discrete Relay I/O Base Module |
| Total I/O Channels | 28 Channels (16 Inputs / 12 Relay Outputs) |
| Discrete Input Voltage | 100...120 V AC (47...63 Hz) |
| Discrete Input Current | 11 mA at 50 Hz / 13 mA at 60 Hz |
| Input Voltage Limits | State 1: ≥ 74 V / State 0: < 20 V |
| Output Voltage Limits | 19...264 V AC / 10...34 V DC |
| Output Contact Type | Normally Open (NO) Contacts |
| Thermal Current (Ith) | 3 A conventional free air thermal current |
| Power Dissipation | 5.6 W |
| Isolation Rating | 1500 V AC for 1 s / 500 V AC continuous |
| Mounting Method | 35 mm DIN Rail Mount |
| Standards Compliance | IEC 1131-2 Type 2; CE, UL, CSA Certified |
| Operating Ambient Thermal Scope | -25°C to +70°C |
| Storage Thermal Scope | -40°C to +85°C |
| Product Net Weight | 0.5 kg (1.1 lb) |
Industrial Applications
- Machinery Control Automation: Interfaces 110V limit switches and control pushbuttons to TSX Micro PLCs.
- Process Actuator Driving: Operates small solenoids, contactors, and indicator lamps via NO relay contacts.
- HVAC & Facility Monitoring: Controls auxiliary pumps, dampers, and status feedback loops in plant panels.
Wiring & Installation
- Rack Mounting: Snap the TSXDMZ28AR onto the TSX Micro rack or DIN rail until the locking clip engages.
- Field Terminal Wiring: Connect 100–120 V AC inputs and relay load wiring directly to the screw terminal block.
- Sensor Compatibility: Wire 2-wire proximity switches directly to input terminals observing voltage limits.
Engineering Advantages
- High Load Capacity: Relay contacts switch up to 220 VA AC resistive/inductive and 40 W 24V DC loads.
- Wide Thermal Endurance: Operates continuously from -25°C to +70°C in demanding panel environments.
- Compact Form Factor: Weighs only 0.5 kg to streamline backplate load distribution.
Technical FAQs
Q1: What input voltage rating does the Schneider TSXDMZ28AR module support?
A1: The module features 16 discrete input channels rated for 100...120 V AC at 47...63 Hz.
Q2: What is the maximum continuous current capacity for the relay outputs?
A2: The NO relay outputs support a conventional free air thermal current (Ith) of 3 A per channel.
Q3: Is the TSXDMZ28AR compatible with 2-wire proximity sensors?
A3: Yes, the input circuitry is fully compatible with 2-wire AC proximity sensors.
Aanvullende specificaties
Scalar (V/f)
Vector
Op netstroom
Koopgids
- Bevestig het exacte model, onderdeelnummer en specificaties voordat u bestelt.
- Zorg voor compatibiliteit met uw huidige machines of besturingssystemen.
- Neem contact op via sale@etowonauto.com of +8617859788089 voor technische ondersteuning.
- Bekijk de leveringsopties, doorlooptijden en verzendvereisten.
- Volg de instructies van de fabrikant en de beste praktijken tijdens de installatie.
Verzending en Retourneren
Voorraadartikelen worden doorgaans dezelfde werkdag verzonden. Voor producten die momenteel niet op voorraad zijn, kunnen de verzendtijden variëren afhankelijk van de beschikbaarheid. Internationale verzending is mogelijk, en de verzendkosten worden berekend op basis van bestemming, gewicht en gekozen vervoerder.
Retourzendingen worden geaccepteerd binnen 30 dagen na ontvangst, mits de artikelen ongebruikt en in originele staat zijn. De kosten voor retourzending zijn voor rekening van de klant. Neem alstublieft contact met ons op voordat u een artikel retourneert om een retourautorisatie te ontvangen.
Voor meer details kunt u onze Verzend- en Retourbeleid raadplegen.

3500/61-05-CN Temperature Monitor Module | Bently Nevada
3500/22-01-02-CN TDI Module Bently Nevada
Bently Nevada 3500/42-04-00 | Seismic Monitor
-
Snelle verzending
Originele onderdelen voor industriële automatisering beschikbaar voor snelle verzending wereldwijd.
-
Eenvoudige Retourzendingen
30 dagen retourrecht met 12 maanden garantie voor betrouwbare nazorgbescherming.
-
24/7 ondersteuning
Responsieve professionele ondersteuning om stabiele en efficiënte bedrijfsvoering te behouden.
-
Echt & Origineel
100% authentiek, rechtstreeks afkomstig van vertrouwde fabrikanten van industriële automatisering.
Technische & Koopgids
-
How Does ABB Fieldbus Cut Industrial Automation Wiring Costs?
ABB fieldbus instruments reduce cable costs by 40-55% and enable real-time DCS diagnostics, yet 62% of faults stem fr...
-
Can Wireless Gas Detection Fix Hard-to-Reach Plant Blind Spots?
This article reviews how the Honeywell Universal Transmitter enables wireless gas detection in hard-to-reach hazardou...
-
How Does GE Cimplicity HMI Tuning Boost Operator Performance?
This article explains how targeted GE Cimplicity HMI tuning improves operator performance in large control rooms. It ...
-
Why Do Continuous Process Plants Need ABB Redundant Networks?
This article examines practical ABB redundant control network design for continuous process plants, covering dual sta...
-
How Do You Install a Bently Nevada Keyphasor Sensor Correctly?
This article explains how to install and align a Bently Nevada keyphasor sensor for turbine TSI monitoring. It covers...
-
How Can You Tune GE Proficy Historian Compression?
This article explains how to tune GE Proficy Historian compression for industrial time-series archives, covering dead...