Transformeer je huis met de nieuwste multi-elektronica oplossingen, van intelligente verlichting tot spraakgestuurde apparaten, allemaal ontworpen om het leven gemakkelijker, veiliger en meer verbonden te maken.
SKU:TSXASY410
Schneider Electric TSXASY410 4 Channel Analog Output
Manufacturer: Schneider
Product No.: TSXASY410
Product Type: Analog Output Module
Product Origin: FR
Payment:T/T, Western Union
Weight: 350g
Shipping port: Xiamen
Warranty: 12 months
Delen
- Snelle levering
- 24/7 Ondersteuning
- Kwaliteitsborging
Beschrijving
Schneider Electric TSXASY410 Modicon Analog Output Module
Schneider Electric TSXASY410 | Analog output module for the Modicon Premium and TSX Micro automation platforms. Provides 4 analog output channels with selectable current (0-20 mA, 4-20 mA) or voltage (±10 V) output. 1500 Vrms channel-to-channel and channel-to-bus isolation. Screw terminal block connection. Weight: 0.35 kg (0.77 lb).
Key Features
4 analog output channels. Selectable current (0-20 mA, 4-20 mA) or voltage (±10 V) output. 11-bit + sign analog/digital conversion. 2.5 ms conversion time. 10.25 µA resolution (current), 5.12 mV resolution (voltage). 1500 Vrms isolation between channels and bus. Overload and short-circuit protection. Screw terminal block connection. CE marked. Made in France.
Technical Specifications
| Manufacturer | Schneider Electric |
| Part Number | TSXASY410 |
| Product Line | TSX Micro PLCs / Modicon Premium |
| Product Type | Analog Output Module |
| Number of Channels | 4 |
| Output Type | Current 0-20 mA, 4-20 mA; Voltage ±10 V |
| Analog/Digital Conversion | 11 bits + sign |
| Conversion Time | 2.5 ms |
| Resolution | 10.25 µA (current); 5.12 mV (voltage) |
| Measurement Error (25°C) | 0.45% FS (±10V); 0.52% FS (0-20mA/4-20mA) |
| Measurement Error (0-60°C) | 0.75% FS (±10V); 0.98% FS (0-20mA/4-20mA) |
| Isolation (Channel to Channel) | 1500 Vrms |
| Isolation (Channel to Bus) | 1500 Vrms |
| Isolation (Channel to Ground) | 500 V |
| Load Impedance (Current) | < 600 Ω (0-20 mA, 4-20 mA) |
| Load Impedance (Voltage) | > 1000 Ω (±10 V) |
| Max Load Inductance | 300 µH |
| Max Load Capacitance | 0.1 µF |
| Output Voltage Limit | ≤ 30 V |
| Current Consumption | 900 mA @ 5V DC |
| Power Supply | 24V DC |
| Power Consumption | 3 W |
| Electrical Connection | Screw terminal block |
| Protection | Overload, short-circuit |
| Dimensions (W x H x D) | 125 x 100 x 40 mm |
| Net Weight | 0.35 kg (0.77 lb) |
| IP Degree of Protection | IP20 |
| Pollution Degree | 2 |
| Operating Temperature | 0°C to +60°C |
| Storage Temperature | -25°C to +70°C |
| Relative Humidity | 10-95% (operation); 5-95% (storage), non-condensing |
| Operating Altitude | 0-2000 m |
| Certifications | CE, UL 508, CSA, IEC 61131-2, GL, ABS, RINA, DNV |
| Country of Origin | France |
Installation Notes
Mount in Modicon Premium or TSX Micro PLC rack. Connect field wiring via screw terminal block. Use shielded cable for analog signals and connect shields to the designated shield terminals. Observe load impedance limits: <600 Ω for current output, >1000 Ω for voltage output. Maintain IP20 enclosure and pollution degree 2 environment. Ensure operating temperature remains between 0°C and 60°C.
Engineering Advantages
Selectable current or voltage output on each channel provides application flexibility. 1500 Vrms channel-to-channel isolation protects against ground loops and noise. High 11-bit + sign resolution ensures precise analog control. Overload and short-circuit protection safeguard the module and connected equipment. Compact 0.35 kg design saves panel space. Marine certifications (GL, ABS, RINA, DNV) enable use in shipboard and offshore applications.
FAQs
Q1: What output types are available?
A1: Current (0-20 mA, 4-20 mA) and voltage (±10 V).
Q2: What is the isolation rating?
A2: 1500 Vrms between channels and bus, 500 V between channels and ground.
Q3: What is the power consumption?
A3: 3 W at 24V DC supply, with 900 mA current consumption at 5V DC.
Aanvullende specificaties
Scalar (V/f)
Vector
Op netstroom
Koopgids
- Bevestig het exacte model, onderdeelnummer en specificaties voordat u bestelt.
- Zorg voor compatibiliteit met uw huidige machines of besturingssystemen.
- Neem contact op via sale@etowonauto.com of +8617859788089 voor technische ondersteuning.
- Bekijk de leveringsopties, doorlooptijden en verzendvereisten.
- Volg de instructies van de fabrikant en de beste praktijken tijdens de installatie.
Verzending en Retourneren
Voorraadartikelen worden doorgaans dezelfde werkdag verzonden. Voor producten die momenteel niet op voorraad zijn, kunnen de verzendtijden variëren afhankelijk van de beschikbaarheid. Internationale verzending is mogelijk, en de verzendkosten worden berekend op basis van bestemming, gewicht en gekozen vervoerder.
Retourzendingen worden geaccepteerd binnen 30 dagen na ontvangst, mits de artikelen ongebruikt en in originele staat zijn. De kosten voor retourzending zijn voor rekening van de klant. Neem alstublieft contact met ons op voordat u een artikel retourneert om een retourautorisatie te ontvangen.
Voor meer details kunt u onze Verzend- en Retourbeleid raadplegen.

3500/61-05-CN Temperature Monitor Module | Bently Nevada
3500/22-01-02-CN TDI Module Bently Nevada
Bently Nevada 3500/42-04-00 | Seismic Monitor
-
Snelle verzending
Originele onderdelen voor industriële automatisering beschikbaar voor snelle verzending wereldwijd.
-
Eenvoudige Retourzendingen
30 dagen retourrecht met 12 maanden garantie voor betrouwbare nazorgbescherming.
-
24/7 ondersteuning
Responsieve professionele ondersteuning om stabiele en efficiënte bedrijfsvoering te behouden.
-
Echt & Origineel
100% authentiek, rechtstreeks afkomstig van vertrouwde fabrikanten van industriële automatisering.
Technische & Koopgids
-
Can You Restore a DCS Controller Without Downtime?
This article explains field-proven backup and recovery workflows for ABB AC800M DCS controllers. It covers pre-backup...
-
What Makes Live Honeywell Transmitter Replacement Safe?
This article explains how industrial automation teams can replace aging Honeywell transmitters online without a full ...
-
How Does Honeywell APC Improve Refinery Yield?
Honeywell APC applies model predictive control to refinery and chemical units, reducing process variability by 30% to...
-
How Can Bently Nevada Vibration Trends Predict Machine Failures?
This article explains how maintenance teams convert raw Bently Nevada TSI vibration trends into actionable predictive...
-
How Does ABB Redundant Control Cut Downtime?
ABB redundant controller architecture removes single point of failure risk in DCS and PLC systems through hot standby...
-
How Does Honeywell Universal Transmitter Improve DCS Gas Safety?
This article examines field integration practices for Honeywell Universal Transmitters within DCS architectures at ch...