Transformeer je huis met de nieuwste multi-elektronica oplossingen, van intelligente verlichting tot spraakgestuurde apparaten, allemaal ontworpen om het leven gemakkelijker, veiliger en meer verbonden te maken.
SKU:171CCC76010
Schneider 171CCC76010 Modicon Momentum M1 Processor
Manufacturer: Schneider
Product No.: 171CCC76010
Product Type: Processor Module
Product Origin: FR
Payment:T/T, Western Union
Weight: 42g
Shipping port: Xiamen
Warranty: 12 months
Delen
- Snelle levering
- 24/7 Ondersteuning
- Kwaliteitsborging
Beschrijving
Product Overview
The Schneider Electric 171CCC76010 is an x86-based M1/M1E Processor Adapter Module belonging to the Modicon Momentum automation platform. Designed for compact, distributed control applications, this unit executes logic instructions at a speed of 1 ms per 1,000 instructions powered by a 32 MHz clock frequency. It manages up to 8,192 discrete I/O bits and 26,048 register I/O words over localized Modbus networks.
Constructed from lightweight Lexan polycarbonate housing, the 171CCC76010 features 512 KB Flash memory and 512 KB RAM (partitioned for up to 240 KB IEC logic or 18 KB LL984 programs). Weighing 0.042 kg (0.093 lbs), it draws 5.0 V DC operating power directly from the connected Momentum I/O base. Physical communication ports include one non-isolated RS-232C port and one dedicated I/O bus port.
Core Technical Advantages
- High-Speed Instruction Execution: Powered by an x86 32 MHz processor delivering precise 1 ms per 1K instruction scan times.
- Versatile Port Connectivity: Integrates a non-isolated RS-232C serial interface alongside a high-density I/O bus port for flexible system expansion.
- Broad Software Tool Support: Fully supported by legacy and modern Schneider software tools including Concept V2.6, Modsoft V2.5+, ProWORX NxT V2.0, and ProWORX 32.
- Lightweight Base-Powered Design: Weighs just 0.042 kg (0.093 lbs) and receives power via direct backplane connection to the Modicon Momentum I/O base unit.
Technical Specifications
| Parameter | Specification Details |
|---|---|
| Brand / Manufacturer | Schneider Electric |
| Product Line | Modicon Momentum Automation Platform |
| Catalog Part Number | 171CCC76010 |
| Product / Component Type | M1 / M1E Processor Adapter Module |
| Processor Architecture | x86-based (Intel / AMD) @ 32 MHz |
| Word Length | 16-bit |
| Memory Capacity | 512 KB Flash / 512 KB RAM (240 KB IEC, 18 KB LL984) |
| Discrete I/O Capacity | 8,192 Inputs / 8,192 Outputs (maximum) |
| Register I/O Capacity | 26,048 Inputs / 26,048 Outputs (maximum) |
| Communication Ports | 1 x RS-232C (non-isolated), 1 x I/O Bus port |
| Execution Speed / Scan Time | 1 ms per 1K instructions |
| Rated Supply Voltage | 5.0 V DC (±5%) supplied via Momentum I/O base |
| Enclosure Material | Lexan polycarbonate |
| Net Unit Weight | 0.042 kg (0.093 lbs) |
| Operating Temperature | 0°C to +60°C (32°F to 140°F) |
| Operating Altitude & Humidity | Up to 2,000 m (6,561 ft); 5% to 96% RH non-condensing |
| Certifications & Standards | CE, UL, cUL, FM Class 1 Division 2, NEMA type 250 |
Installation & Gap Calibration Guide
- Base Mounting: Align and snap the 171CCC76010 module directly on top of the host Modicon Momentum I/O base unit.
- Communication Interface: Connect the RS-232C serial communication cable or the I/O bus cable into the designated ports.
- Power Activation: Supply 24 V DC power to the underlying Momentum I/O base unit, which steps down power to supply 5.0 V DC to the processor.
Technical FAQs
Q1: What is the primary function of the Schneider 171CCC76010 processor adapter?
A1: It executes control logic and manages I/O expansion for Modicon Momentum system bases. (91 chars)
Q2: What is the difference between ports on the 171CCC76010 versus the 171CCC78010?
A2: The 171CCC76010 has an I/O bus port and RS-232C, while the 171CCC78010 has RS-485 Modbus and RS-232C. (98 chars)
Q3: How much power does the 171CCC76010 require?
A3: It requires 5.0 V DC (±5%), which is fed directly from the connected Momentum I/O base. (89 chars)
Aanvullende specificaties
- Bruin
- DC-gevoed
- Op netstroom
- Op batterijen werkend
- Modulair
Scalar (V/f)
Vector
Op netstroom
Koopgids
- Bevestig het exacte model, onderdeelnummer en specificaties voordat u bestelt.
- Zorg voor compatibiliteit met uw huidige machines of besturingssystemen.
- Neem contact op via sale@etowonauto.com of +8617859788089 voor technische ondersteuning.
- Bekijk de leveringsopties, doorlooptijden en verzendvereisten.
- Volg de instructies van de fabrikant en de beste praktijken tijdens de installatie.
Verzending en Retourneren
Voorraadartikelen worden doorgaans dezelfde werkdag verzonden. Voor producten die momenteel niet op voorraad zijn, kunnen de verzendtijden variëren afhankelijk van de beschikbaarheid. Internationale verzending is mogelijk, en de verzendkosten worden berekend op basis van bestemming, gewicht en gekozen vervoerder.
Retourzendingen worden geaccepteerd binnen 30 dagen na ontvangst, mits de artikelen ongebruikt en in originele staat zijn. De kosten voor retourzending zijn voor rekening van de klant. Neem alstublieft contact met ons op voordat u een artikel retourneert om een retourautorisatie te ontvangen.
Voor meer details kunt u onze Verzend- en Retourbeleid raadplegen.

3500/61-05-CN Temperature Monitor Module | Bently Nevada
3500/22-01-02-CN TDI Module Bently Nevada
Bently Nevada 3500/42-04-00 | Seismic Monitor
-
Snelle verzending
Originele onderdelen voor industriële automatisering beschikbaar voor snelle verzending wereldwijd.
-
Eenvoudige Retourzendingen
30 dagen retourrecht met 12 maanden garantie voor betrouwbare nazorgbescherming.
-
24/7 ondersteuning
Responsieve professionele ondersteuning om stabiele en efficiënte bedrijfsvoering te behouden.
-
Echt & Origineel
100% authentiek, rechtstreeks afkomstig van vertrouwde fabrikanten van industriële automatisering.
Technische & Koopgids
-
Can Converged PLC-DCS Architecture Cut Downtime by 22%?
This article examines how PLC-DCS convergence resolves the fragmentation bottleneck in legacy process plants. Drawing...
-
Retrofitting Mixed PLC & DCS Systems?
This article presents a hybrid protocol fusion architecture combining Modbus TCP and EtherNet/IP to overcome communic...
-
Original vs Compatible GE Fanuc PLC Parts?
This guide presents a data-driven methodology for identifying and verifying brand-new, original GE Fanuc 90-30, 90-70...
-
Can Data-Driven Alarm Grading Reduce Turbine Downtime?
This technical article presents a data-driven four-tier alarm grading strategy for Bently Nevada 3500 systems in comb...
-
How does ABB S800 I/O hot swap cut unplanned downtime by 90%?
This article presents quantified operational best practices for ABB S800 I/O hot swap in 24/7 process industries. ...
-
Is Your Refinery DCS Ready for Zero-Trust OT Access Control?
This technical article examines data-driven cybersecurity hardening strategies for Emerson DeltaV DCS in refiner...
