Transformeer je huis met de nieuwste multi-elektronica oplossingen, van intelligente verlichting tot spraakgestuurde apparaten, allemaal ontworpen om het leven gemakkelijker, veiliger en meer verbonden te maken.
SKU:KCD2-STC-EX1
Pepperl+Fuchs KCD2-STC-Ex1 Transmitter Power Supply
Manufacturer: Pepperl+Fuchs
Product No.: KCD2-STC-EX1
Product Type: Power Supply
Product Origin: DE
Payment:T/T, Western Union
Weight: 150g
Shipping port: Xiamen
Warranty: 12 months
Delen
- Snelle levering
- 24/7 Ondersteuning
- Kwaliteitsborging
Beschrijving
Pepperl+Fuchs KCD2-STC-Ex1 SMART Transmitter Power Supply
The Pepperl+Fuchs KCD2-STC-Ex1 is a transmitter power supply for field instruments. This SMART device provides power to 2-wire transmitters in hazardous areas. It ensures reliable operation for analog measurement devices. The Pepperl+Fuchs KCD2-STC-Ex1 offers intrinsic safety for process control applications.
Product Identification
- Manufacturer: Pepperl+Fuchs
- Product Number: KCD2-STC-Ex1
- Product Type: SMART Transmitter Power Supply
- Signal Type: Analog Input for field transmitters
- Connection Side: Field side installation
- Protection Rating: IP20 enclosure
Power Specifications
- Power Consumption: 1.1 Watt maximum
- Power Connection: Power Rail or terminals 9+, 10-
- Switching Frequency: < 10 Hz operation
- Circuit Protection: Intrinsic safety design
- Power Delivery: For 2-wire transmitters
Connection Details
- Field Terminals: 1+, 2+, 3- for transmitter wiring
- Connection Type: Screw terminal connections
- Wiring: Supports standard field wiring
- Installation: DIN rail mounting standard
- Interface: Compatible with Power Rail system
Physical Specifications
- Dimensions: 1.2 x 11.4 x 12.4 cm (W x H x D)
- Weight: 0.15 kg (150 grams) net weight
- Shipping Weight: 1.5 kg packaged weight
- Enclosure: Compact industrial housing
- Mounting: Standard 35mm DIN rail
Functional Characteristics
- Transmitter Power: Supplies 2-wire field devices
- Signal Conditioning: Analog input processing
- Safety Design: Intrinsically safe for Ex areas
- Monitoring: Transmitter status indication
- Compatibility: Works with SMART transmitters
Environmental Ratings
- Protection Class: IP20 for indoor use
- Temperature Range: Standard industrial rating
- Hazardous Areas: ATEX/IECEx certified
- EMC Compliance: Industrial electromagnetic standards
- Vibration: Suitable for industrial environments
Installation Guidelines
- Mount on 35mm DIN rail in control cabinet
- Connect power via Power Rail or terminal blocks
- Wire field transmitter to terminals 1+, 2+, 3-
- Follow intrinsic safety wiring requirements
- Verify proper grounding and barrier installation
- Check transmitter compatibility before connection
Certifications & Safety
- Intrinsic Safety: Ex ia certification for Zone 0/1
- ATEX: European hazardous area compliance
- IECEx: International explosive atmosphere standards
- Quality Standards: Pepperl+Fuchs manufacturing quality
- EMC: Electromagnetic compatibility compliance
System Integration
- Control Systems: Compatible with DCS and PLC systems
- Transmitters: Supports SMART/HART field devices
- Power Systems: Integrates with Power Rail distribution
- Safety Systems: Suitable for SIL-rated applications
- Networking: Process instrument network compatibility
Frequently Asked Questions (FAQ)
What type of transmitters does this power supply support?
The Pepperl+Fuchs KCD2-STC-Ex1 powers 2-wire SMART and HART transmitters with analog signals.
Can I use this in Zone 0 hazardous areas?
Yes, with proper installation it is certified for Zone 0/1 hazardous locations.
What is the Power Rail connection option?
Power Rail allows daisy-chain power connection without individual wiring to each device.
How many transmitters can one unit power?
Typically one transmitter per unit, depending on the transmitter's power requirements.
What wiring configuration do terminals 1+, 2+, 3- support?
These terminals accommodate standard 2-wire transmitter connections with signal and power.
Is special training required for installation?
Installation should be performed by qualified personnel familiar with intrinsic safety requirements.
For technical support or to order the KCD2-STC-Ex1, contact sale@etowonauto.com.
Content provided by Etowon Auto.
Aanvullende specificaties
- Blauw
Scalar (V/f)
Vector
Op netstroom
Koopgids
- Bevestig het exacte model, onderdeelnummer en specificaties voordat u bestelt.
- Zorg voor compatibiliteit met uw huidige machines of besturingssystemen.
- Neem contact op via sale@etowonauto.com of +8617859788089 voor technische ondersteuning.
- Bekijk de leveringsopties, doorlooptijden en verzendvereisten.
- Volg de instructies van de fabrikant en de beste praktijken tijdens de installatie.
Verzending en Retourneren
Voorraadartikelen worden doorgaans dezelfde werkdag verzonden. Voor producten die momenteel niet op voorraad zijn, kunnen de verzendtijden variëren afhankelijk van de beschikbaarheid. Internationale verzending is mogelijk, en de verzendkosten worden berekend op basis van bestemming, gewicht en gekozen vervoerder.
Retourzendingen worden geaccepteerd binnen 30 dagen na ontvangst, mits de artikelen ongebruikt en in originele staat zijn. De kosten voor retourzending zijn voor rekening van de klant. Neem alstublieft contact met ons op voordat u een artikel retourneert om een retourautorisatie te ontvangen.
Voor meer details kunt u onze Verzend- en Retourbeleid raadplegen.

3500/61-05-CN Temperature Monitor Module | Bently Nevada
3500/22-01-02-CN TDI Module Bently Nevada
Bently Nevada 3500/42-04-00 | Seismic Monitor
-
Snelle verzending
Originele onderdelen voor industriële automatisering beschikbaar voor snelle verzending wereldwijd.
-
Eenvoudige Retourzendingen
30 dagen retourrecht met 12 maanden garantie voor betrouwbare nazorgbescherming.
-
24/7 ondersteuning
Responsieve professionele ondersteuning om stabiele en efficiënte bedrijfsvoering te behouden.
-
Echt & Origineel
100% authentiek, rechtstreeks afkomstig van vertrouwde fabrikanten van industriële automatisering.
Technische & Koopgids
-
What Makes 50ms Failover Critical for Industry 4.0 Smart Factories?
This article examines ABB DCS full-link redundancy design for pharmaceutical manufacturing under GMP and Industry 4.0...
-
Wat zijn de hoofdoorzaken van intermitterende TSI-communicatiefouten?
Dit artikel biedt een kwantitatieve probleemoplossingsmethode voor communicatieproblemen tussen GE Fanuc PLC en Bentl...
-
How to Secure Emerson DeltaV DCS Under Industry 4.0?
This article presents practical Emerson DeltaV DCS hardening strategies aligned with IEC 62443 standards for process ...
-
Is Your Metallurgical Plant Losing Millions to Hidden Energy Waste?
Metallurgical plants waste substantial energy due to fragmented PLC and DCS architectures that cannot share real-time...
-
How to Migrate GE Fanuc to Allen-Bradley Without Production Downtime?
This article provides a data-driven migration guide from GE Fanuc to Allen-Bradley PLCs for discrete manufacturing. I...
-
How Can Bently Nevada Kits Cut Centrifugal Machinery Downtime?
This article shows how Bently Nevada turnkey kits reduce unplanned downtime for centrifugal compressors and fans. It ...
