Transformeer je huis met de nieuwste multi-elektronica oplossingen, van intelligente verlichting tot spraakgestuurde apparaten, allemaal ontworpen om het leven gemakkelijker, veiliger en meer verbonden te maken.
SKU:1756-L72S
Logix5572S PAC Controller | Allen-Bradley 1756-L72S
Manufacturer: Allen-Bradley
Product No.: 1756-L72S
Product Type: Safety Processor
Product Origin: USA
Payment:T/T, Western Union
Weight: 250g
Shipping port: Xiamen
Warranty: 12 months
Delen
- Snelle levering
- 24/7 Ondersteuning
- Kwaliteitsborging
Beschrijving
Product Overview
The Allen-Bradley 1756-L72S is a high-performance GuardLogix 5570 Programmable Automation Controller (PAC) engineered by Rockwell Automation. This dual-processor module integrates standard and safety control functions within a single project file, maximizing processing capabilities for motion and complex logic applications. Featuring 4 MB of standard user memory and 2 MB of dedicated safety memory, it serves as the primary controller alongside a required 1756-L7SP (or 1756-L7SPK) safety partner module to achieve stringent SIL 3, PLe, and Cat. 4 safety ratings. Weighing only 0.55 lbs (0.25 kg), this batteryless processor utilizes modern energy storage modules (ESM) to maintain volatile memory security without maintenance downtime.
Key Advantages
- Unified Control Architecture: Combines standard machine control and functional safety systems into one unified hardware slot and application software project.
- Battery-Free Operation: Equipped with an integrated 1756-ESMCAP energy storage capacitor, eliminating the environmental impact and replacement schedules associated with traditional lithium batteries.
- Massive I/O Scalability: Supports up to 128,000 digital I/O points and up to 4,000 analog I/O points across local backplanes or distributed industrial networks.
- Lightweight Slot Integration: Weighing just 0.55 lbs, the open-style enclosure installs effortlessly into any slot of a ControlLogix 1756 chassis, allowing multiple processors to co-exist in the same frame.
- Robust Non-Volatile Memory: Ships with a pre-installed 1 GB 1784-SD1 Secure Digital card, ensuring secure firmware back-up and boot loading, expandable up to 2 GB via 1784-SD2.
Technical Specifications
| Model Number | 1756-L72S (Logix5572S) |
| Manufacturer | Allen-Bradley / Rockwell Automation |
| Series / Family | GuardLogix 5570 / ControlLogix |
| Standard User Memory | 4 MB |
| Safety Memory | 2 MB |
| I/O Memory | 0.98 MB |
| Safety Partner Module | 1756-L7SP / 1756-L7SPK (Required) |
| Non-Volatile Storage | 1 GB SD Card (1784-SD1 included, supports up to 2 GB) |
| Net Weight | 0.55 lbs (0.25 kg) |
| Current Draw | 800 mA @ 5.1V DC / 5 mA @ 1.2V DC |
| Power & Thermal Dissipation | 2.5 Watts / 8.5 BTU per hour |
| Isolation Voltage | 30V Continuous (Basic Insulation) |
Quick Installation Tips
- Slot Layout Planning: The 1756-L72S is an open-style module that can be inserted into any standard slot of a 1756 ControlLogix chassis. However, it must be paired in a neighboring slot with its safety partner, the 1756-L7SP module. Despite their minimal combined weight (each processor is only 0.55 lbs), ensure both modules are locked into the backplane connectors firmly.
- Chassis and Power Compatibility: This processor is fully compatible with standard or conformally coated chassis assemblies (e.g., 1756-A4, 1756-A7, 1756-A10, up to 1756-A17 standard/K-series) and can be powered by standard industrial power supplies like the 1756-PA75 or 1756-PB75 ranges.
- Energy Storage Selection: The unit comes standard with the integrated 1756-ESMCAP capacitor. If your site applications prohibit USB configuration or SD card utilization for enhanced security, consider replacing it with the 1756-ESMNRM module. For systems requiring immediate power cuts without residual clock uptime, select the 1756-ESMNSE option.
Technical FAQs
Q1: Is the safety partner module configured separately from the 1756-L72S primary module?
A1: No. The safety partner controller (1756-L7SP) is automatically configured by the system. Both standard and safety routines are developed and compiled within a single, integrated project environment, drastically cutting engineering time compared to isolated safety solutions.
Q2: What communication capabilities are built onto the front faceplate of the module?
A2: The 1756-L72S features a built-in USB port intended for programming, configuration, firmware updates, and rapid online diagnostics. For real-time plant network communication and safety I/O data links, separate EtherNet/IP, ControlNet, or DeviceNet communication bridge modules must be added to the chassis.
Q3: How many tasks can this processor handle concurrently?
A3: The controller supports a maximum of 31 standard tasks and 1 dedicated safety task, with a high capacity of up to 100 separate logic programs allowed per single task. Event tasks can be triggered by all supported system event types.
Aanvullende specificaties
Scalar (V/f)
Vector
Op netstroom
Koopgids
- Bevestig het exacte model, onderdeelnummer en specificaties voordat u bestelt.
- Zorg voor compatibiliteit met uw huidige machines of besturingssystemen.
- Neem contact op via sale@etowonauto.com of +8617859788089 voor technische ondersteuning.
- Bekijk de leveringsopties, doorlooptijden en verzendvereisten.
- Volg de instructies van de fabrikant en de beste praktijken tijdens de installatie.
Verzending en Retourneren
Voorraadartikelen worden doorgaans dezelfde werkdag verzonden. Voor producten die momenteel niet op voorraad zijn, kunnen de verzendtijden variëren afhankelijk van de beschikbaarheid. Internationale verzending is mogelijk, en de verzendkosten worden berekend op basis van bestemming, gewicht en gekozen vervoerder.
Retourzendingen worden geaccepteerd binnen 30 dagen na ontvangst, mits de artikelen ongebruikt en in originele staat zijn. De kosten voor retourzending zijn voor rekening van de klant. Neem alstublieft contact met ons op voordat u een artikel retourneert om een retourautorisatie te ontvangen.
Voor meer details kunt u onze Verzend- en Retourbeleid raadplegen.

3500/61-05-CN Temperature Monitor Module | Bently Nevada
3500/22-01-02-CN TDI Module Bently Nevada
Bently Nevada 3500/42-04-00 | Seismic Monitor
-
Snelle verzending
Originele onderdelen voor industriële automatisering beschikbaar voor snelle verzending wereldwijd.
-
Eenvoudige Retourzendingen
30 dagen retourrecht met 12 maanden garantie voor betrouwbare nazorgbescherming.
-
24/7 ondersteuning
Responsieve professionele ondersteuning om stabiele en efficiënte bedrijfsvoering te behouden.
-
Echt & Origineel
100% authentiek, rechtstreeks afkomstig van vertrouwde fabrikanten van industriële automatisering.
Technische & Koopgids
-
Can Proper Warehousing Cut Automation Hardware Failures 80%?
This technical guide presents quantified storage and maintenance standards for industrial PLC, DCS, and TSI spare par...
-
Can Industrial Control Upgrades Cut Unplanned Downtime by 90%?
This article examines why legacy PLC, DCS, and vibration monitoring systems demand urgent retrofit in 2026. Citing re...
-
How to streamline industrial automation spare parts import clearance?
This guide delivers a data-driven framework for sourcing and clearing industrial automation spare parts, covering PLC...
-
How Fast Must DCS Switchover Be to Prevent Costly Process Upsets?
This article presents quantified DCS redundancy strategies using real 2024–2025 plant data. It details sub-100ms swit...
-
Why Is Explosion-Proof DCS Critical for Chemical Plant Safety?
This technical article examines how optimized multi-vendor explosion-proof DCS architectures address critical safety ...
-
How to restore Allen‑Bradley PLCs to 99.8% performance?
This technical article presents new, factory-original industrial automation hardware solutions for power plants and p...
