Transformeer je huis met de nieuwste multi-elektronica oplossingen, van intelligente verlichting tot spraakgestuurde apparaten, allemaal ontworpen om het leven gemakkelijker, veiliger en meer verbonden te maken.
SKU:KCD2-SOT-EX1.LB
KCD2-SOT-Ex1.LB Isolated Barrier | Pepperl+Fuchs
Manufacturer: Pepperl+Fuchs
Product No.: KCD2-SOT-EX1.LB
Product Type: Switch Amplifier
Product Origin: DE
Payment:T/T, Western Union
Weight: 100g
Shipping port: Xiamen
Warranty: 12 months
Delen
- Snelle levering
- 24/7 Ondersteuning
- Kwaliteitsborging
Beschrijving
Pepperl+Fuchs KCD2-SOT-Ex1.LB Switch Amplifier
The Pepperl+Fuchs KCD2-SOT-Ex1.LB is an isolated switch amplifier for hazardous areas. This 1-channel barrier interfaces NAMUR sensors with control systems. It provides two transistor outputs for signal splitting applications. The Pepperl+Fuchs KCD2-SOT-Ex1.LB offers safe operation in explosive atmospheres with ATEX certification.
Product Identification
- Manufacturer: Pepperl+Fuchs
- Model Number: KCD2-SOT-Ex1.LB switch amplifier
- Product Type: 1-Channel Isolated Barrier
- Primary Function: Digital input signal conditioning
- Safety Rating: SIL 2, SC 3 per IEC/EN 61508
- Certification: ATEX certified for hazardous areas
- Housing Width: 12.5 mm compact design
Power Supply Specifications
- Supply Voltage: 24 V DC nominal (19-30 V DC range)
- Connection: Power Rail or terminals 9+, 10-
- Rated Current: 20-15 mA typical consumption
- Power Dissipation: ≤ 700 mW maximum
- Ripple Tolerance: ≤ 10 % input ripple
Input Specifications
- Signal Type: Digital Input (NAMUR or dry contact)
- Connection: Terminals 1+, 2- (field side)
- NAMUR Values: 10 V DC / 8 mA per EN 60947-5-6
- Switching Point: 1.2-2.1 mA with 0.2 mA hysteresis
- Line Fault Detection: Breakage I ≤ 0.1 mA, short I ≥ 6.5 mA
- Pulse Requirements: Min. 100 µs pulse/pause ratio
Output Performance
- Output Channels: Two passive transistor outputs
- Connection: Output I: terminals 5,6; Output II: terminals 7,8
- Rated Voltage: 30 V DC maximum
- Rated Current: 50 mA per output
- Response Time: ≤ 200 µs fast switching
- 1-Signal Level: (External voltage) - 3V max at 50 mA
- 0-Signal Level: Blocked output (≤10 µA leakage)
- Switching Frequency: ≤ 5 kHz maximum
Safety & Isolation
- Safety Level: SIL 2, Systematic Capability SC 3
- Galvanic Isolation: Reinforced insulation 300 Veff
- Isolation Ratings: Input/Output: 300 Veff reinforced
- Hazardous Area: ATEX certified [Ex ia Ga] IIC
- Protection Degree: IP20 for indoor use
Configuration & Display
- Configuration: DIP switch settings
- Display Elements: LED status indicators
- Labeling: Front space for identification
- Operating Mode: Reversible operation possible
- Signal Splitting: 1 input to 2 outputs capability
Environmental Specifications
- Temperature Range: -20°C to +70°C standard
- Extended Range: Up to 70°C with derating
- Mounting: 35 mm DIN rail per EN 60715
- Dimensions: 12.5 x 119 x 114 mm (WxHxD)
- Weight: Approx. 100 grams
Certifications & Compliance
- ATEX Certificate: BASEEFA 13 ATEX 0080
- Marking: II (1)G [Ex ia Ga] IIC, II (1)D [Ex ia Da] IIIC
- EMC Directive: 2014/30/EU, EN 61326-1:2013
- Safety Standards: IEC 61010-1:2010 compliance
Installation Guidelines
- Mount on 35 mm DIN rail in appropriate enclosure
- Connect 24V DC power via Power Rail or terminals
- Wire NAMUR sensor or dry contact to input terminals
- Connect outputs to control system inputs
- Configure DIP switches for required operation mode
- Verify proper grounding for hazardous area installation
Frequently Asked Questions (FAQ)
What is the main purpose of this switch amplifier?
The Pepperl+Fuchs KCD2-SOT-Ex1.LB safely interfaces hazardous area sensors with control systems.
Can I use this with standard mechanical contacts?
Yes, it accepts both NAMUR sensors and dry contact inputs.
What does "signal splitter" function mean?
It can take one input signal and provide two identical output signals.
How does line fault detection work?
It detects open circuits (<0.1 mA) and short circuits (>6.5 mA) in field wiring.
What hazardous area classifications does it support?
ATEX Zone 0/1 for gas and Zone 20/21 for dust explosive atmospheres.
What configuration options are available?
DIP switches allow setting operating mode, output configuration, and fault behavior.
For technical specifications or to order the KCD2-SOT-Ex1.LB, email sale@etowonauto.com.
Content provided by Etowon Auto.
Aanvullende specificaties
- Blauw
Scalar (V/f)
Vector
Op netstroom
Koopgids
- Bevestig het exacte model, onderdeelnummer en specificaties voordat u bestelt.
- Zorg voor compatibiliteit met uw huidige machines of besturingssystemen.
- Neem contact op via sale@etowonauto.com of +8617859788089 voor technische ondersteuning.
- Bekijk de leveringsopties, doorlooptijden en verzendvereisten.
- Volg de instructies van de fabrikant en de beste praktijken tijdens de installatie.
Verzending en Retourneren
Voorraadartikelen worden doorgaans dezelfde werkdag verzonden. Voor producten die momenteel niet op voorraad zijn, kunnen de verzendtijden variëren afhankelijk van de beschikbaarheid. Internationale verzending is mogelijk, en de verzendkosten worden berekend op basis van bestemming, gewicht en gekozen vervoerder.
Retourzendingen worden geaccepteerd binnen 30 dagen na ontvangst, mits de artikelen ongebruikt en in originele staat zijn. De kosten voor retourzending zijn voor rekening van de klant. Neem alstublieft contact met ons op voordat u een artikel retourneert om een retourautorisatie te ontvangen.
Voor meer details kunt u onze Verzend- en Retourbeleid raadplegen.

3500/61-05-CN Temperature Monitor Module | Bently Nevada
3500/22-01-02-CN TDI Module Bently Nevada
Bently Nevada 3500/42-04-00 | Seismic Monitor
-
Snelle verzending
Originele onderdelen voor industriële automatisering beschikbaar voor snelle verzending wereldwijd.
-
Eenvoudige Retourzendingen
30 dagen retourrecht met 12 maanden garantie voor betrouwbare nazorgbescherming.
-
24/7 ondersteuning
Responsieve professionele ondersteuning om stabiele en efficiënte bedrijfsvoering te behouden.
-
Echt & Origineel
100% authentiek, rechtstreeks afkomstig van vertrouwde fabrikanten van industriële automatisering.
Technische & Koopgids
-
What Makes 50ms Failover Critical for Industry 4.0 Smart Factories?
This article examines ABB DCS full-link redundancy design for pharmaceutical manufacturing under GMP and Industry 4.0...
-
Wat zijn de hoofdoorzaken van intermitterende TSI-communicatiefouten?
Dit artikel biedt een kwantitatieve probleemoplossingsmethode voor communicatieproblemen tussen GE Fanuc PLC en Bentl...
-
How to Secure Emerson DeltaV DCS Under Industry 4.0?
This article presents practical Emerson DeltaV DCS hardening strategies aligned with IEC 62443 standards for process ...
-
Is Your Metallurgical Plant Losing Millions to Hidden Energy Waste?
Metallurgical plants waste substantial energy due to fragmented PLC and DCS architectures that cannot share real-time...
-
How to Migrate GE Fanuc to Allen-Bradley Without Production Downtime?
This article provides a data-driven migration guide from GE Fanuc to Allen-Bradley PLCs for discrete manufacturing. I...
-
How Can Bently Nevada Kits Cut Centrifugal Machinery Downtime?
This article shows how Bently Nevada turnkey kits reduce unplanned downtime for centrifugal compressors and fans. It ...