Product Overview
The GE Energy IS215ACLEH1B (Functional Acronym: ACLE) is a high-performance Application Control Layer Module designed for General Electric's Mark VI Speedtronic Gas Turbine Control Systems and EX2100 / EX2100e Excitation Control Systems. Engineered for critical industrial control applications, this microprocessor-based controller manages real-time turbine control logic, subsystem coordination, complex communication protocols, and system diagnostics.
Featuring an "IS215" domestic special modular assembly prefix, the IS215ACLEH1B is built with a dual-slot metal faceplate tailored for standard GE VME rack structures and control cabinets. Operating with a 125 V DC input voltage and 24 V DC output, it incorporates a high-speed PCI controller, 128 KB L2 cache, 10BaseT RJ45 Ethernet communication, non-volatile flash memory, and an array of front-panel LED status indicators. Weighing approximately 0.57 kg (1.25 lbs), this Grade B functional revision module delivers robust online application loading and real-time control block processing across demanding energy environments.
Core Technical Advantages
- Advanced Microprocessor & PCI Controller Architecture: Equipped with an onboard CPU, PCI controller, and 128 KB Level 2 cache to optimize data transfers and high-speed input/output processing.
- Comprehensive Network & Bus Connectivity: Features 10BaseT RJ45 Ethernet (IRQ 5 initialization via BIOS) for seamless communication over ISBus networks, SCADA systems, and central control hubs.
- Flexible Software & Logic Capabilities: Supports online application configuration loading, non-volatile flash memory storage, control block execution, and real-time forcing of I/O points and internal booleans.
- VME Rack & Dual-Slot Integration: Engineered with a specialized installation faceplate that occupies two half-slots in standard EX2100 exciter board racks or Innovation Series drives.
Technical Specifications
| Parameter | Specification Details |
|---|---|
| Brand / Manufacturer | General Electric / GE Energy |
| Full Catalog Part Number | IS215ACLEH1B |
| Product Series | Mark VI Series / EX2100 & EX2100e Excitation System |
| Functional Acronym | ACLE (Application Control Layer) |
| Product Description | Application Control Layer Module |
| Input / Output Voltage | Input: 125 V DC | Output: 24 V DC |
| Operating Temperature Range | -30°C to +65°C (-22°F to +149°F) |
| Cache Architecture | Level 2, 128 KB (Controlled via PCI Controller) |
| Ethernet Port Type | 10BaseT RJ45 Connector (Front Panel) |
| Mounting & Rack Form Factor | VME Rack Structure / Occupies 2 Half-Slots (Faceplate) |
| Board Dimensions | 23.495 cm (H) x 10.795 cm (W) |
| Functional Revision | 1 B (Singular B-grade functional revision) |
| Country of Manufacture | United States (USA) |
| Estimated Shipping Weight | Approx. 0.57 kg (1.25 lbs) |
Installation & Handling Guidelines
- ESD Protection & Static Safety: Always handle the ACLE board using a grounded wrist strap and static-safe equipment to avoid damaging onboard microprocessors and flash memory ICs.
- VME Rack Slot Insertion: Align the metal faceplate guide rails carefully into the two half-slots of the EX2100 exciter rack or Innovation drive cabinet before securing the faceplate retaining screws.
- Ethernet & Cable Connection: Connect standard RJ45 Ethernet cabling directly to the front-panel 10BaseT port, ensuring correct pin alignment and cable strain relief within the cabinet.
Technical FAQs
Q1: What is the main function of the GE IS215ACLEH1B module in turbine control systems?
A1: It executes control logic, manages communication networks, enforces safety protocols, and coordinates subsystems.
Q2: How does the IS215ACLEH1B module mount within the control cabinet?
A2: It uses a metal installation faceplate designed to occupy two half-slots in standard EX2100 VME racks.
Q3: What Ethernet communication interface is featured on the front panel of the IS215ACLEH1B board?
A3: It features a 10BaseT RJ45 jack initialized by BIOS, managed via an onboard PCI controller.
Aanvullende specificaties
- Groen
Scalar (V/f)
Vector
Op netstroom
Koopgids
- Bevestig het exacte model, onderdeelnummer en specificaties voordat u bestelt.
- Zorg voor compatibiliteit met uw huidige machines of besturingssystemen.
- Neem contact op via sale@etowonauto.com of +8617859788089 voor technische ondersteuning.
- Bekijk de leveringsopties, doorlooptijden en verzendvereisten.
- Volg de instructies van de fabrikant en de beste praktijken tijdens de installatie.
Verzending en Retourneren
Voorraadartikelen worden doorgaans dezelfde werkdag verzonden. Voor producten die momenteel niet op voorraad zijn, kunnen de verzendtijden variëren afhankelijk van de beschikbaarheid. Internationale verzending is mogelijk, en de verzendkosten worden berekend op basis van bestemming, gewicht en gekozen vervoerder.
Retourzendingen worden geaccepteerd binnen 30 dagen na ontvangst, mits de artikelen ongebruikt en in originele staat zijn. De kosten voor retourzending zijn voor rekening van de klant. Neem alstublieft contact met ons op voordat u een artikel retourneert om een retourautorisatie te ontvangen.
Voor meer details kunt u onze Verzend- en Retourbeleid raadplegen.

3500/61-05-CN Temperature Monitor Module | Bently Nevada
3500/22-01-02-CN TDI Module Bently Nevada
Bently Nevada 3500/42-04-00 | Seismic Monitor
-
Snelle verzending
Originele onderdelen voor industriële automatisering beschikbaar voor snelle verzending wereldwijd.
-
Eenvoudige Retourzendingen
30 dagen retourrecht met 12 maanden garantie voor betrouwbare nazorgbescherming.
-
24/7 ondersteuning
Responsieve professionele ondersteuning om stabiele en efficiënte bedrijfsvoering te behouden.
-
Echt & Origineel
100% authentiek, rechtstreeks afkomstig van vertrouwde fabrikanten van industriële automatisering.
Technische & Koopgids
-
How Does TSI Integration Reduce Turbine False Trip Risks?
This article examines data-driven turbine safety monitoring and mechanical fault diagnosis within industrial automati...
-
Can turn-key automation services really cut plant downtime by 47%?
This article examines how fragmented PLC, DCS, TSI, and power-protection systems drive hidden operational losses in p...
-
Is Your Manufacturing Execution Still Stuck in Open-Loop Mode?
This article examines how closed-loop automated control resolves the critical disconnect between production planning ...
-
Can Predictive Analytics Cut Factory Automation Downtime?
This article examines how predictive abnormality pre-judgment technology addresses the economic burden of reactive fa...
-
Is Full PLC Replacement Best for Brown-Field Automation?
This technical article analyzes the hidden costs of full-scale PLC and DCS hardware replacement in brown-field plants...
-
Is Your DCS Logic Tuning Ready for Real-World Production Loads?
This article examines the critical role of physical on-site commissioning and logic tuning in industrial automation, ...