Transformeer je huis met de nieuwste multi-elektronica oplossingen, van intelligente verlichting tot spraakgestuurde apparaten, allemaal ontworpen om het leven gemakkelijker, veiliger en meer verbonden te maken.
SKU:IS200EPCTG1A
GE IS200EPCTG1A Simplex Exciter PT CT Terminal Module
Manufacturer: General Electric
Product No.: IS200EPCTG1A
Product Type: Terminal Board
Product Origin: USA
Payment:T/T, Western Union
Weight: 450g
Shipping port: Xiamen
Warranty: 12 months
Delen
- Snelle levering
- 24/7 Ondersteuning
- Kwaliteitsborging
Beschrijving
Product Overview
The General Electric IS200EPCTG1A (functional acronym EPCT) is an Exciter PT/CT Input/Output Terminal Board developed for the GE EX2100 Series Excitation Control System. Designed for process-critical power generation environments, this module receives, conditions, scales, and isolates feedback signals from potential transformers (PTs) and current transformers (CTs) directly monitoring two three-phase generator lines.
Operating on a 28 V DC power supply, the IS200EPCTG1A features integrated isolation transformers (T1 through T6) that convert high-level generator feedback signals into low-voltage signals routed via J305, J308, and J315 connectors to the main controller boards (such as EMIO in M1, M2, or C controllers). Weighing 0.45 kg (0.99 lbs) with compact dimensions of 23.8 cm x 8.6 cm, the board operates across an extended industrial temperature range of -30°C to +65°C.
Core Technical Advantages
- Comprehensive Signal Isolation: Six internal isolation transformers (T1–T6) scale and isolate 115 V rms PT inputs and 1 A/5 A CT current signals for safe system feedback.
- Simplex & Triple Redundant Support: Fully scalable for Simplex systems or redundant control architectures using up to three EPCT boards in parallel.
- Flexible Analog Input Configuration: Features jumper JP1 selection to accept either 0–10 V DC or 4–20 mA field analog instrumentation signals.
- Enhanced Terminal Safety: Features non-removable TB2/TB3 terminal blocks to prevent hazardous CT open-circuit conditions during operational service.
Technical Specifications
| Parameter | Specification Details |
|---|---|
| Brand / Manufacturer | General Electric (GE) |
| Part / Catalog Number | IS200EPCTG1A |
| Functional Acronym | EPCT (Exciter PT/CT Terminal Board) |
| System Compatibility | GE EX2100 Excitation Control System |
| PT Input Rating | 115 V rms @ 50/60 Hz (Two 3-phase generator PT inputs) |
| PT Step-Down Voltage Output | 1.533 V rms (from 115 V rms 3-wire open delta input) |
| CT Input Rating | 1 A or 5 A nominal inputs from two generators |
| PT/CT Input Burden | Less than 1 VA |
| Auxiliary Analog Input | 1 Channel: 0 to 10 V DC or 4 to 20 mA (Jumper JP1 selectable) |
| Power Supply Voltage | 28 V DC |
| Terminal Blocks & Wiring | 3 Blocks (TB1 removable; TB2/TB3 fixed); supports up to #10 AWG |
| Board Dimensions | 23.8 cm High x 8.6 cm Wide (9.37 in x 3.38 in) |
| Net Board Weight | 0.45 kg (0.99 lbs) |
| Operating Temperature | -30°C to +65°C (-22°F to +149°F) |
Installation & Gap Calibration Guide
- Field Wiring Connection: Wire CT and PT secondary signals to terminal block TB1 using up to #10 AWG cable (maximum run length 1,000 feet / 300 meters).
- Jumper Configuration: Set jumper JP1 to configure the auxiliary analog input for either 0–10 V DC voltage or 4–20 mA current mode prior to powering up.
- CT Safety Notice: Ensure terminal blocks TB2 and TB3 remain permanently attached to prevent dangerous open-circuit voltage spikes across live CT secondaries.
Technical FAQs
Q1: What is the main function of the GE IS200EPCTG1A terminal board?
A1: It conditions, isolates, and scales generator PT and CT feedback signals for EX2100 exciters. (94 chars)
Q2: Why are terminal blocks TB2 and TB3 non-removable on the IS200EPCTG1A?
A2: They are fixed to protect personnel and equipment from open-circuit CT high-voltage hazards. (95 chars)
Q3: How are secondary signals routed to EX2100 system controllers?
A3: Isolated secondary signals are cabled via J305, J308, and J315 connectors to the EMIO board. (93 chars)
Aanvullende specificaties
- Groen
Scalar (V/f)
Vector
Op netstroom
Koopgids
- Bevestig het exacte model, onderdeelnummer en specificaties voordat u bestelt.
- Zorg voor compatibiliteit met uw huidige machines of besturingssystemen.
- Neem contact op via sale@etowonauto.com of +8617859788089 voor technische ondersteuning.
- Bekijk de leveringsopties, doorlooptijden en verzendvereisten.
- Volg de instructies van de fabrikant en de beste praktijken tijdens de installatie.
Verzending en Retourneren
Voorraadartikelen worden doorgaans dezelfde werkdag verzonden. Voor producten die momenteel niet op voorraad zijn, kunnen de verzendtijden variëren afhankelijk van de beschikbaarheid. Internationale verzending is mogelijk, en de verzendkosten worden berekend op basis van bestemming, gewicht en gekozen vervoerder.
Retourzendingen worden geaccepteerd binnen 30 dagen na ontvangst, mits de artikelen ongebruikt en in originele staat zijn. De kosten voor retourzending zijn voor rekening van de klant. Neem alstublieft contact met ons op voordat u een artikel retourneert om een retourautorisatie te ontvangen.
Voor meer details kunt u onze Verzend- en Retourbeleid raadplegen.

3500/61-05-CN Temperature Monitor Module | Bently Nevada
3500/22-01-02-CN TDI Module Bently Nevada
Bently Nevada 3500/42-04-00 | Seismic Monitor
-
Snelle verzending
Originele onderdelen voor industriële automatisering beschikbaar voor snelle verzending wereldwijd.
-
Eenvoudige Retourzendingen
30 dagen retourrecht met 12 maanden garantie voor betrouwbare nazorgbescherming.
-
24/7 ondersteuning
Responsieve professionele ondersteuning om stabiele en efficiënte bedrijfsvoering te behouden.
-
Echt & Origineel
100% authentiek, rechtstreeks afkomstig van vertrouwde fabrikanten van industriële automatisering.
Technische & Koopgids
-
Can Converged PLC-DCS Architecture Cut Downtime by 22%?
This article examines how PLC-DCS convergence resolves the fragmentation bottleneck in legacy process plants. Drawing...
-
Retrofitting Mixed PLC & DCS Systems?
This article presents a hybrid protocol fusion architecture combining Modbus TCP and EtherNet/IP to overcome communic...
-
Original vs Compatible GE Fanuc PLC Parts?
This guide presents a data-driven methodology for identifying and verifying brand-new, original GE Fanuc 90-30, 90-70...
-
Can Data-Driven Alarm Grading Reduce Turbine Downtime?
This technical article presents a data-driven four-tier alarm grading strategy for Bently Nevada 3500 systems in comb...
-
How does ABB S800 I/O hot swap cut unplanned downtime by 90%?
This article presents quantified operational best practices for ABB S800 I/O hot swap in 24/7 process industries. ...
-
Is Your Refinery DCS Ready for Zero-Trust OT Access Control?
This technical article examines data-driven cybersecurity hardening strategies for Emerson DeltaV DCS in refiner...
