GE IC697CHS783 Series 90-70 VME Integrator Chassis
Manufacturer: General Electric
Product No.: IC697CHS783
Product Type: I/O Rack
Product Origin: USA
Payment:T/T, Western Union
Weight: 8200g
Shipping port: Xiamen
Warranty: 12 months
Delen
- Snelle levering
- 24/7 Ondersteuning
- Kwaliteitsborging
Beschrijving
Product Overview
The IC697CHS783 is a high-capacity 17-Slot VME Integrator Rack belonging to the GE Fanuc Series 90-70 and PACSystems RX7i controller families. Built with a highly flexible VME standard C.1 compliant backplane, this chassis permits seamless co-processing by hosting both standard GE modules and 3rd-party VME-based boards. It serves as the ultimate structural and communications foundation for advanced, high-speed industrial data processing and large-scale plant automation setups.
Core Features
- 17-Slot VME Backplane: Supports open-architecture VME standard C.1 for mixing 3rd-party and proprietary modules.
- Dual Mounting Profiles: Reversible engineering adapts to standard 19-inch front racks or 10-inch deep rear panels.
- Integrated Latches: Robust molded alignment latches hold plug-in cards firmly against heavy machinery vibration.
- Configurable Rack ID: Onboard physical jumpers (JP1–JP4) allow rapid hardware address tuning across multi-rack networks.
Technical Specifications
| Parameter | Data |
|---|---|
| Model Number | IC697CHS783 |
| Total Card Slots | 17 Slots (VME Standard C.1 Compliant) |
| Backplane Power Drawing | 3.3A @ 5 VDC and 1.1A @ 12 VDC (Single power source compatible) |
| Chassis Net Weight | 8.2 kg (18.08 lbs) |
| Physical Dimensions | 11.15" (H) × 19.00" (W) × 7.50" (D) |
| Enclosure Fitting Depth | Fits 10-inch deep back enclosures (Rear-mount option) |
| Address Jumpers | 4 Hardware Jumpers (JP1 through JP4) for Rack ID allocation |
| Environmental Tolerance | −20°C to +60°C (−4°F to 140°F); 5% to 95% RH non-condensing |
| Optional Cooling Link | Supports IC697ACC721 120VAC ball-bearing fan tray (20,000-hour lifespan) |
Engineering & Installation Guide
- Rack ID Configuration: Set physical hardware jumpers JP1 to JP4 to define the rack ID before mounting the unit. Misconfigured jumpers cause immediate I/O addressing bus conflicts with the CPU.
- Mechanical Load Management: Given the substantial 8.2 kg empty base weight, ensure your standard 19-inch rack rails or enclosure sub-panels are fully anchored to sustain the total weight load once all 17 slots are populated with heavy boards.
- Thermal Optimizations: For ambient operations trending near the +60°C maximum limit, or when using power-hungry 3rd-party VME computing cards, always fit the optional IC697ACC721 ball-bearing fan tray to prevent hot-spot stagnation.
Technical FAQs
Q1: What does VME Standard C.1 compliance mean for this integrator rack?
A1: It indicates an open-architecture backplane interface. Instead of restricting you to standard GE Fanuc modules, it allows engineers to integrate specialized 3rd-party VME-bus cards (like custom network links or high-speed processing modules) directly into the same hardware loop.
Q2: Can the IC697CHS783 chassis operate from separate power supplies for the 5V and 12V rails?
A2: No. The internal backplane power distribution network is strictly optimized for a unified, single power source supply configuration that manages both the 3.3A @ 5VDC and 1.1A @ 12VDC loads simultaneously to maintain system synchronization.
Q3: How do the molded latches prevent hardware failures in high-vibration plants?
A3: Microphonic vibration can cause slotted cards to walk out of their backplane seating over time, inducing tracking data faults. The factory-molded mechanical latches lock each module faceplate into the rigid frame, guaranteeing consistent, vibration-proof electrical contact.
Aanvullende specificaties
Scalar (V/f)
Vector
Op netstroom
Koopgids
- Bevestig het exacte model, onderdeelnummer en specificaties voordat u bestelt.
- Zorg voor compatibiliteit met uw huidige machines of besturingssystemen.
- Neem contact op via sale@etowonauto.com of +8617859788089 voor technische ondersteuning.
- Bekijk de leveringsopties, doorlooptijden en verzendvereisten.
- Volg de instructies van de fabrikant en de beste praktijken tijdens de installatie.
Verzending en Retourneren
Voorraadartikelen worden doorgaans dezelfde werkdag verzonden. Voor producten die momenteel niet op voorraad zijn, kunnen de verzendtijden variëren afhankelijk van de beschikbaarheid. Internationale verzending is mogelijk, en de verzendkosten worden berekend op basis van bestemming, gewicht en gekozen vervoerder.
Retourzendingen worden geaccepteerd binnen 30 dagen na ontvangst, mits de artikelen ongebruikt en in originele staat zijn. De kosten voor retourzending zijn voor rekening van de klant. Neem alstublieft contact met ons op voordat u een artikel retourneert om een retourautorisatie te ontvangen.
Voor meer details kunt u onze Verzend- en Retourbeleid raadplegen.

3500/61-05-CN Temperature Monitor Module | Bently Nevada
3500/22-01-02-CN TDI Module Bently Nevada
Bently Nevada 3500/42-04-00 | Seismic Monitor
-
Snelle verzending
Originele onderdelen voor industriële automatisering beschikbaar voor snelle verzending wereldwijd.
-
Eenvoudige Retourzendingen
30 dagen retourrecht met 12 maanden garantie voor betrouwbare nazorgbescherming.
-
24/7 ondersteuning
Responsieve professionele ondersteuning om stabiele en efficiënte bedrijfsvoering te behouden.
-
Echt & Origineel
100% authentiek, rechtstreeks afkomstig van vertrouwde fabrikanten van industriële automatisering.
Technische & Koopgids
-
Waarom is een failover van 50 ms cruciaal voor slimme fabrieken in Industrie 4.0?
Dit artikel onderzoekt het ABB DCS full-link redundantieontwerp voor farmaceutische productie onder GMP- en Industry ...
-
Wat zijn de hoofdoorzaken van intermitterende TSI-communicatiefouten?
Dit artikel biedt een kwantitatieve probleemoplossingsmethode voor communicatieproblemen tussen GE Fanuc PLC en Bentl...
-
How to Secure Emerson DeltaV DCS Under Industry 4.0?
This article presents practical Emerson DeltaV DCS hardening strategies aligned with IEC 62443 standards for process ...
-
Is Your Metallurgical Plant Losing Millions to Hidden Energy Waste?
Metallurgical plants waste substantial energy due to fragmented PLC and DCS architectures that cannot share real-time...
-
How to Migrate GE Fanuc to Allen-Bradley Without Production Downtime?
This article provides a data-driven migration guide from GE Fanuc to Allen-Bradley PLCs for discrete manufacturing. I...
-
How Can Bently Nevada Kits Cut Centrifugal Machinery Downtime?
This article shows how Bently Nevada turnkey kits reduce unplanned downtime for centrifugal compressors and fans. It ...