Transformeer je huis met de nieuwste multi-elektronica oplossingen, van intelligente verlichting tot spraakgestuurde apparaten, allemaal ontworpen om het leven gemakkelijker, veiliger en meer verbonden te maken.
SKU:IC693CPU374-HX
GE Fanuc IC693CPU374-HX Series 90-30 CPU Module 133MHz
Manufacturer: General Electric
Product No.: IC693CPU374-HX
Product Type: CPU Module
Product Origin: USA
Payment:T/T, Western Union
Weight: 350g
Shipping port: Xiamen
Warranty: 12 months
Delen
- Snelle levering
- 24/7 Ondersteuning
- Kwaliteitsborging
Beschrijving
Product Overview
The GE Fanuc IC693CPU374-HX is a high-performance, single-slot CPU module belonging to the Series 90-30 Programmable Logic Controller (PLC) family. Powered by a 133 MHz AMD SC520 processor, it executes Boolean instructions at a rapid rate of 0.15 μsec per instruction. The CPU provides 240KB of configurable user memory (RAM backed by Flash) to handle complex PLC logic routines and extensive data tables. Designed with integrated Ethernet capability, the IC693CPU374-HX delivers high-speed communication and remote programming support in a compact 0.35 kg (0.77 lbs) form factor.
Core Technical Advantages
- High-Speed 133 MHz Logic Engine: Utilizes an AMD SC520 133 MHz processor with a 0.15 μsec execution time per Boolean instruction, optimizing scan cycles for complex processing.
- 240KB Configurable User Memory: Features 240KB (245,760 Bytes) of battery-backed RAM and non-volatile Flash storage, allowing dynamic allocation across registers (%R), analog inputs (%AI), and analog outputs (%AQ).
- Broad I/O Capacity: Supports 2,048 fixed discrete input (%I) and 2,048 fixed discrete output (%Q) points, accommodating extensive industrial automation layouts.
- Compact Single-Slot Design: Weighs just 0.35 kg and mounts directly into slot 1 of any standard Series 90-30 baseplate, saving valuable backplane space.
Technical Specifications
| Parameter | Specification Details |
|---|---|
| Brand / Manufacturer | GE Fanuc / Emerson Automation (Series 90-30) |
| Model Part Number | IC693CPU374-HX |
| Module Net Weight | 0.35 kg (0.77 lbs) |
| Processor Architecture | AMD SC520 running at 133 MHz |
| Execution Speed | 0.15 μsec per Boolean instruction |
| User Program Memory | 240KB (245,760 Bytes) RAM backed by Flash storage |
| Discrete I/O Capacity | 2,048 Discrete Inputs (%I) / 2,048 Discrete Outputs (%Q) |
| Internal Logic Bits | 4,096 Internal Coils (%M) / 1,280 Global Bits (%G) / 256 Temporary Coils (%T) |
| Configurable Memory Registers | %R, %AI, and %AQ configurable from 128 to 32,640 words each |
| System Registers & Status | 28 System Registers (%SR) / 128 System Status bits (%S, %SA, %SB, %SC) |
| Form Factor / Placement | Single-slot width (installs into CPU Slot 1 of 90-30 baseplate) |
Installation & Programming Guidelines
- Baseplate Mounting: Insert the 0.35 kg CPU module strictly into Slot 1 (adjacent to the power supply unit) of a Series 90-30 Modular Baseplate. Ensure power to the baseplate is disconnected before physical insertion or removal.
- Memory Configuration: Configure memory allocations (%R register words, %AI analog inputs, and %AQ analog outputs) via Proficy Machine Edition. Total allocation must stay within the maximum 240KB user memory ceiling.
- Battery Backup Installation: Ensure a fresh lithium battery module is connected to the CPU board port prior to powering off the rack to maintain user logic and volatile register tables in RAM.
Technical FAQs
Q1: What is the benefit of the Flash memory alongside RAM in the IC693CPU374-HX?
A1: While battery-backed RAM provides rapid read/write execution during operation, the non-volatile Flash memory allows engineers to back up user logic and configuration data permanently, protecting against complete logic loss during long power outages or battery failures.
Q2: How are register (%R) and analog (%AI / %AQ) limits determined on this CPU?
A2: Unlike fixed discrete bit counts, the register and analog word pools are user-configurable in software from 128 up to 32,640 words, depending on how much of the 240KB total memory is assigned to program logic vs. data storage.
Q3: Which slot on the Series 90-30 rack should the IC693CPU374-HX occupy?
A3: The IC693CPU374-HX is a single-slot CPU and must always be installed in CPU Slot 1 (directly next to the power supply module) of a Series 90-30 modular baseplate.
Aanvullende specificaties
Scalar (V/f)
Vector
Op netstroom
Koopgids
- Bevestig het exacte model, onderdeelnummer en specificaties voordat u bestelt.
- Zorg voor compatibiliteit met uw huidige machines of besturingssystemen.
- Neem contact op via sale@etowonauto.com of +8617859788089 voor technische ondersteuning.
- Bekijk de leveringsopties, doorlooptijden en verzendvereisten.
- Volg de instructies van de fabrikant en de beste praktijken tijdens de installatie.
Verzending en Retourneren
Voorraadartikelen worden doorgaans dezelfde werkdag verzonden. Voor producten die momenteel niet op voorraad zijn, kunnen de verzendtijden variëren afhankelijk van de beschikbaarheid. Internationale verzending is mogelijk, en de verzendkosten worden berekend op basis van bestemming, gewicht en gekozen vervoerder.
Retourzendingen worden geaccepteerd binnen 30 dagen na ontvangst, mits de artikelen ongebruikt en in originele staat zijn. De kosten voor retourzending zijn voor rekening van de klant. Neem alstublieft contact met ons op voordat u een artikel retourneert om een retourautorisatie te ontvangen.
Voor meer details kunt u onze Verzend- en Retourbeleid raadplegen.

3500/61-05-CN Temperature Monitor Module | Bently Nevada
3500/22-01-02-CN TDI Module Bently Nevada
Bently Nevada 3500/42-04-00 | Seismic Monitor
-
Snelle verzending
Originele onderdelen voor industriële automatisering beschikbaar voor snelle verzending wereldwijd.
-
Eenvoudige Retourzendingen
30 dagen retourrecht met 12 maanden garantie voor betrouwbare nazorgbescherming.
-
24/7 ondersteuning
Responsieve professionele ondersteuning om stabiele en efficiënte bedrijfsvoering te behouden.
-
Echt & Origineel
100% authentiek, rechtstreeks afkomstig van vertrouwde fabrikanten van industriële automatisering.
Technische & Koopgids
-
What Are the Hidden Costs of Fake PLC and DCS Modules?
This guide presents data-driven verification protocols for imported industrial control spare parts, addressing the es...
-
Redundant PLC + DCS: 18.6% Fan Energy Savings?
This case study documents a full automation retrofit for a 300 TPD waste incineration plant. By integrating Emerson D...
-
Can Proper Warehousing Cut Automation Hardware Failures 80%?
This technical guide presents quantified storage and maintenance standards for industrial PLC, DCS, and TSI spare par...
-
Can Industrial Control Upgrades Cut Unplanned Downtime by 90%?
This article examines why legacy PLC, DCS, and vibration monitoring systems demand urgent retrofit in 2026. Citing re...
-
How to streamline industrial automation spare parts import clearance?
This guide delivers a data-driven framework for sourcing and clearing industrial automation spare parts, covering PLC...
-
How Fast Must DCS Switchover Be to Prevent Costly Process Upsets?
This article presents quantified DCS redundancy strategies using real 2024–2025 plant data. It details sub-100ms swit...
