Transformeer je huis met de nieuwste multi-elektronica oplossingen, van intelligente verlichting tot spraakgestuurde apparaten, allemaal ontworpen om het leven gemakkelijker, veiliger en meer verbonden te maken.
SKU:FC-IOTA-NR24
FC-IOTA-NR24 Honeywell Safety Manager IOTA
Manufacturer: Honeywell
Product No.: FC-IOTA-NR24
Product Type: Termination Assembly
Product Origin: USA
Payment:T/T, Western Union
Weight: 310g
Shipping port: Xiamen
Warranty: 12 months
Delen
- Snelle levering
- 24/7 Ondersteuning
- Kwaliteitsborging
Beschrijving
Product Overview
The FC-IOTA-NR24 is a compact, non-redundant Input/Output Termination Assembly (IOTA) engineered for high-integrity safety applications. Certified for use in safety instrumented functions up to SIL 3 compliance (IEC 61508/61511), this module serves as the rugged field wiring interface for Honeywell Safety Manager systems. It bridges field instrumentation directly to processing logic by hosting critical safety modules, guaranteeing extreme precision and fail-safe operation in hazardous environments like chemical plants and refineries.
Core Technical Advantages
- High-Density Universal I/O: Provides 32 flexible software-configurable channels, minimizing physical footprint and hardware overhead.
- SIL 3 Safety Compliance: Engineered to meet strict IEC 61508 standards for Emergency Shutdown (ESD) and safety-critical control.
- Robust Power Infrastructure: Features integrated reverse-polarity protection and a heavy-duty 15A fuse to safeguard internal circuitry.
- Dual Network Continuity: Equipped with dual RJ45 ports for deterministic 100MB Ethernet communication across control networks.
Technical Specifications
| Parameter | Specification Details |
|---|---|
| Model Number | FC-IOTA-NR24 |
| Module Compatibility | Supports 1x RUSIO-3224 or RUSLS-3224 module |
| I/O Capacity | 32 Universal I/O Channels (CN1, CN2) + 4 V+ Connections (CN3) |
| Supported I/O Types | Digital Input, ESD Input, Analog Input/Output, Digital Output |
| Power Supply | 24V DC (-15% to +30%), Max. 10A load |
| Circuit Protection | Parallel Diode (Reverse Polarity), Littelfuse 15A Blade Fuse |
| Network Interface | 2x RJ45 Connectors (100MB Ethernet via RIOLA / RIOLB) |
| Operating Conditions | -40°C to +70°C; 10% to 95% RH (Non-condensing) |
| Dimensions (H x W x D) | 64 x 120.7 x 293.4 mm |
| Approvals | CE, UL, TUV, Pollution Degree 2 |
Installation & Maintenance Guide
Wiring and Connections
Secure the 24V DC input wires to the dedicated 24V and COM screws on the carrier power rails. Connect active Analog Input (AI) field devices to the four identical V+ power distribution points labeled CN3, and route general field signals to headers CN1 and CN2.
Environmental and Mounting Guidelines
Mount the assembly horizontally or vertically inside a Pollution Degree 2 (or better) rated enclosure to prevent dust buildup. Ensure ambient temperatures remain between -40°C and +70°C to prevent thermal stress or drift in critical channels.
Fuse Replacement Safeties
If a power surge trips the circuit protection, always isolate power before servicing. Replace only with an identical 15A, 32V DC automotive blade fuse (Manufacturer Part Number: Littelfuse 0287015.PXS) to maintain certified safety tolerances.
Engineering Advantages
- Universal Flexibility: Eliminates the need to buy separate analog and digital modules, allowing mixed loop configurations on a single board.
- Extreme Resilience: Operates reliably from -40°C up to +70°C, matching the demands of remote instrument enclosures without auxiliary cooling.
- Fail-Safe Communication: Dual RJ45 ports (RIOLA/RIOLB) support dual-path network data routing to prevent safety loop disconnects.
Technical FAQs
Q1: What types of I/O modules can be installed on the FC-IOTA-NR24?
A1: The assembly accommodates exactly one RUSIO-3224 or one RUSLS-3224 module, providing full software-configurable control over mixed signal types.
Q2: Can this termination assembly be used in redundant configurations?
A2: No. The FC-IOTA-NR24 is strictly a non-redundant (NR) assembly. For high-availability redundant architectures, a dedicated redundant-type IOTA baseboard must be selected.
Q3: What is the purpose of the CN3 connections on this assembly?
A3: The CN3 interface supplies four independent, filtered V+ power loops specifically designed to drive active 2-wire or 3-wire analog field transmitters.
Aanvullende specificaties
- Groen
- DC-gevoed
- Compact
- Modulair
Scalar (V/f)
Vector
Op netstroom
Koopgids
- Bevestig het exacte model, onderdeelnummer en specificaties voordat u bestelt.
- Zorg voor compatibiliteit met uw huidige machines of besturingssystemen.
- Neem contact op via sale@etowonauto.com of +8617859788089 voor technische ondersteuning.
- Bekijk de leveringsopties, doorlooptijden en verzendvereisten.
- Volg de instructies van de fabrikant en de beste praktijken tijdens de installatie.
Verzending en Retourneren
Voorraadartikelen worden doorgaans dezelfde werkdag verzonden. Voor producten die momenteel niet op voorraad zijn, kunnen de verzendtijden variëren afhankelijk van de beschikbaarheid. Internationale verzending is mogelijk, en de verzendkosten worden berekend op basis van bestemming, gewicht en gekozen vervoerder.
Retourzendingen worden geaccepteerd binnen 30 dagen na ontvangst, mits de artikelen ongebruikt en in originele staat zijn. De kosten voor retourzending zijn voor rekening van de klant. Neem alstublieft contact met ons op voordat u een artikel retourneert om een retourautorisatie te ontvangen.
Voor meer details kunt u onze Verzend- en Retourbeleid raadplegen.

3500/61-05-CN Temperature Monitor Module | Bently Nevada
3500/22-01-02-CN TDI Module Bently Nevada
Bently Nevada 3500/42-04-00 | Seismic Monitor
-
Snelle verzending
Originele onderdelen voor industriële automatisering beschikbaar voor snelle verzending wereldwijd.
-
Eenvoudige Retourzendingen
30 dagen retourrecht met 12 maanden garantie voor betrouwbare nazorgbescherming.
-
24/7 ondersteuning
Responsieve professionele ondersteuning om stabiele en efficiënte bedrijfsvoering te behouden.
-
Echt & Origineel
100% authentiek, rechtstreeks afkomstig van vertrouwde fabrikanten van industriële automatisering.
Technische & Koopgids
-
What Makes 50ms Failover Critical for Industry 4.0 Smart Factories?
This article examines ABB DCS full-link redundancy design for pharmaceutical manufacturing under GMP and Industry 4.0...
-
Wat zijn de hoofdoorzaken van intermitterende TSI-communicatiefouten?
Dit artikel biedt een kwantitatieve probleemoplossingsmethode voor communicatieproblemen tussen GE Fanuc PLC en Bentl...
-
How to Secure Emerson DeltaV DCS Under Industry 4.0?
This article presents practical Emerson DeltaV DCS hardening strategies aligned with IEC 62443 standards for process ...
-
Is Your Metallurgical Plant Losing Millions to Hidden Energy Waste?
Metallurgical plants waste substantial energy due to fragmented PLC and DCS architectures that cannot share real-time...
-
How to Migrate GE Fanuc to Allen-Bradley Without Production Downtime?
This article provides a data-driven migration guide from GE Fanuc to Allen-Bradley PLCs for discrete manufacturing. I...
-
How Can Bently Nevada Kits Cut Centrifugal Machinery Downtime?
This article shows how Bently Nevada turnkey kits reduce unplanned downtime for centrifugal compressors and fans. It ...
